P-98 laser reference sensor
P-98 laser reference sensor: sensors and measurement devices by Brüel & Kjær Vibro for vibration.
Download the datasheet (opens in a new tab) This series on the Brüel & Kjær Vibro site (opens in a new tab)
Models in the series
One column per model: what differs between the models of the series.
| Parameter | P-98 eli-m-a5d9b92173d6428ffa71b751 |
|---|---|
| Operating temperature | -10–40 °C |
| Protection class (DIN EN 60529) | ip67 |
| Status | Active |
| Datasheet | PDF — P-98 (opens in a new tab) |
The industries we serve
Frequently asked questions
Answers to the most common questions about our products and services
It is a laser reference sensor for rotational speed and an angular reference on a rotating component. It detects a reflective mark on that component.
The manual specifies direct connection through AC-1388. Match wiring and sensor power to the instrument; the documented typical supply is 5 VDC at 30 mA.
The documented optical working range is 100–2000 mm. Stabilize and align the sensor so its indicator responds when the reference mark passes.
The manual permits stable manual positioning or a magnetic stand such as AC-525. The stand provides mounting and does not change signal type or measuring range.
The specification lists IP67 and an operating range of −10 to +40 °C. It is a Class 2 laser; do not look into the beam.
Get a quote or advice