VIBROCONTROL 1800 Series Vibration controllers
VIBROCONTROL 1800 Series: measurement controllers by Brüel & Kjær Vibro for vibration controllers.
Download the datasheet (opens in a new tab) Visit the Brüel & Kjær Vibro site (opens in a new tab)Models in the series
One column per model: what differs between the models of the series.
| Parameter | VC-1850 eli-m-86c6c89abbb25744981a5e16 | VC-1860 eli-m-b24448cab0eefde819fad58c | VC-1870 eli-m-b7f1252331812abad1d4d548 |
|---|---|---|---|
| Frequency response | 0.7–10000 Hz | 0.7–10000 Hz | 0.7–10000 Hz |
| Operating temperature | -10–50 °C | -10–50 °C | Not specified |
| Number of measurement channels | 4 | 4 | 4 |
| Status | Active | Active | Active |
| Datasheet | PDF — VC-1850 (opens in a new tab) | PDF — VC-1860 (opens in a new tab) |
The industries we serve
Frequently asked questions
Answers to the most common questions about our products and services
VC-1850 accepts constant-current-powered accelerometers, VC-1860 velocity sensors, and VC-1870 displacement sensors. Select the input type for the sensor and required measurement.
No. There are 4 vibration inputs and one speed input. The remaining input is for a process variable on VC-1850/1860, or axial shaft position on VC-1870.
No. The specification lists 4.8 or 24 kHz sample rates separately from filter bands extending to 10 kHz. Select sampling and filters for the measurement.
Raw data from up to 4 channels can be recorded simultaneously to a computer. Mini USB is documented for real-time transfer and RS-485/LAN for buffered transfer, under the specified conditions.
The measuring module requires a power supply and compatible sensors. Relay, communication and storage modules are selected as needed; units interconnect through DIN-rail bus connectors.
Get a quote or advice
Tell us what you need and an engineer will come back to you.