VIBROCONTROL 950/960 Vibration controllers
VIBROCONTROL 950/960: measurement controllers by Brüel & Kjær Vibro for vibration controllers.
Download the datasheet (opens in a new tab) This series on the Brüel & Kjær Vibro site (opens in a new tab)Models in the series
One column per model: what differs between the models of the series.
| Parameter | VC-950 eli-m-8e4f1715ac74528167f354aa | VC-950/01 eli-m-66f5472fb041a15d6f9e0a52 | VC-960 eli-m-faad326c3861492ac047d719 | VC-960/01 eli-m-826bd4c71691814f04b1f6d1 |
|---|---|---|---|---|
| Operating temperature | -10–50 °C | -10–50 °C | -10–50 °C | -10–50 °C |
| Number of measurement channels | 1 | 1 | 1 | 1 |
| Status | Active | Active | Active | Active |
| Datasheet | PDF — VC-950 (opens in a new tab) | PDF — VC-950/01 (opens in a new tab) | PDF — VC-960 (opens in a new tab) | PDF — VC-960/01 (opens in a new tab) |
The industries we serve
Frequently asked questions
Answers to the most common questions about our products and services
VC-950 accepts constant-current-powered accelerometers, while VC-960 accepts vibration-velocity sensors. Choose for sensor type, sensitivity and signal interface.
It provides configurable Alert and Danger levels with delays to reduce alarms from brief transients. A latch can retain the alarm until manual or remote reset.
The 4–20 mA output represents vibration level relative to the configured range, with loads up to 400 Ω. Alarm relays provide a separate alarm or control connection.
Compact Setup configures measurement ranges, alarm limits and delays. The factory frequency band is 10–1000 Hz at −1 dB; other bands can be selected for the instrument and measurement.
The DIN-rail unit is rated IP20. VC-950/01 and VC-960/01 are supplied in an IP65 field housing. Select the version for the required ingress protection.
Get a quote or advice
Tell us what you need and an engineer will come back to you.