Skip to content

VIBROPORT 8000 (VP-8000) Data acquisition

VIBROPORT 8000 (VP-8000): data acquisition systems by Brüel & Kjær Vibro for data acquisition.

Download the datasheet (opens in a new tab) This series on the Brüel & Kjær Vibro site (opens in a new tab)

Shared technical specifications for the series

Properties every model in the series has. What differs is in the models table below.

Range across models

The span covered by the models of the series together — not the range of each model.

Range across the models of VIBROPORT 8000 (VP-8000)
Number of measurement channels 4–24

Models in the series

One column per model: what differs between the models of the series.

Models of VIBROPORT 8000 (VP-8000) compared by parameter
Parameter C107835.001 eli-m-8f47f37285cc30011b8f3cde C107836.001 eli-m-ba4d307207b32898fb13c728 C107836.002 eli-m-8f6ed07247ebeee3dca0a519 C107836.003 eli-m-f10e7da864b082e35e740aa0 C107836.004 eli-m-7de229af2b299f71c1e345c8 C107836.0045 eli-m-0deef27957c08b6ba62e6432 VIBROPORT 8000 eli-m-12830a4bc3bea5858b98748e
Frequency response 0–20000 Hz 0–20000 Hz 0–20000 Hz 0–20000 Hz 0–20000 Hz 0–20000 Hz 0–20000 Hz
Number of measurement channels 24 16 4 8 12 20 24
interface_specification Not specified Not specified Not specified Not specified Not specified Not specified UMM-to-RJ45 sensor/data connection
Temperature measuring range Not specified Not specified Not specified Not specified Not specified Not specified 20–65 °C
source_linearity_basis Not specified Not specified Not specified Not specified Not specified Not specified Official selected specification: DC–20 kHz accuracy ±0.3% of selected full scale or ±1.0 mV DC; this is analyzer signal-conditioning accuracy, not attached-sensor accuracy.
source_repeatability_basis Not specified Not specified Not specified Not specified Not specified Not specified Repeatability of the complete sensor + VP-8000 chain is not published; validate the selected sensor, mounting and calibration route.
Operating temperature Not specified Not specified Not specified Not specified Not specified Not specified -20–65 °C
source_sampling_rate_basis Not specified Not specified Not specified Not specified Not specified Not specified The source publishes synchronous sampling choices of 16, 32, 64, 128, 256, 512 and 1048 samples/revolution; no single fixed time-domain sample rate is stated.
quantity_specification Not specified Not specified Not specified Not specified Not specified Not specified Portable VC-8000-based data-acquisition system; removable 32 GB SD and optional 256 GB SSD; environmental range −20…+65 °C and 5–95% RH non-condensing.
Accuracy (% FSO) Not specified Not specified Not specified Not specified Not specified Not specified 0.3 %
Interfaces Not specified Not specified Not specified Not specified Not specified Not specified ethernet
Status Active Active Active Active Active Active Active
Datasheet PDF — C107835.001 (opens in a new tab) PDF — C107836.001 (opens in a new tab) PDF — C107836.002 (opens in a new tab) PDF — C107836.003 (opens in a new tab) PDF — C107836.004 (opens in a new tab) PDF — C107836.0045 (opens in a new tab)

The industries we serve

Frequently asked questions

Answers to the most common questions about our products and services

It is a portable vibration-analysis and temporary-monitoring system for rotating and reciprocating machinery, such as during startup, shutdown or after maintenance. It uses VC-8000 monitoring modules and SETPOINT CMS.

The documented configurations provide 4–24 channels. Each UMM supports up to 4 inputs for compatible sensors or process signals, according to configuration.

No. It can store data locally without a connected computer, or stream to an external computer or AVEVA PI. SETPOINT CMS provides viewing and diagnostics.

Compatible protection-system buffered outputs can connect through BNC and the documented cabling. Match module input mode and impedance to the signal type.

The portable setup software does not provide many protection functions, including relays. For protection-system use, the manufacturer specifies the VC-8000 setup and maintenance software and manual.

Didn't find the answer you were looking for?

Talk to an expert

More information

Get a quote or advice

Tell us what you need and an engineer will come back to you.

Request a quote for this product
What would you like to ask for?

Email or phone — one of them is enough

Email or phone — one of them is enough