Range across models
The span covered by the models of the series together — not the range of each model.
| Number of measurement channels | 4–24 |
|---|
Models in the series
One column per model: what differs between the models of the series.
| Parameter | C107835.001 eli-m-8f47f37285cc30011b8f3cde | C107836.001 eli-m-ba4d307207b32898fb13c728 | C107836.002 eli-m-8f6ed07247ebeee3dca0a519 | C107836.003 eli-m-f10e7da864b082e35e740aa0 | C107836.004 eli-m-7de229af2b299f71c1e345c8 | C107836.0045 eli-m-0deef27957c08b6ba62e6432 | VIBROPORT 8000 eli-m-12830a4bc3bea5858b98748e |
|---|---|---|---|---|---|---|---|
| Frequency response | 0–20000 Hz | 0–20000 Hz | 0–20000 Hz | 0–20000 Hz | 0–20000 Hz | 0–20000 Hz | 0–20000 Hz |
| Number of measurement channels | 24 | 16 | 4 | 8 | 12 | 20 | 24 |
| interface_specification | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | UMM-to-RJ45 sensor/data connection |
| Temperature measuring range | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | 20–65 °C |
| source_linearity_basis | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Official selected specification: DC–20 kHz accuracy ±0.3% of selected full scale or ±1.0 mV DC; this is analyzer signal-conditioning accuracy, not attached-sensor accuracy. |
| source_repeatability_basis | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Repeatability of the complete sensor + VP-8000 chain is not published; validate the selected sensor, mounting and calibration route. |
| Operating temperature | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | -20–65 °C |
| source_sampling_rate_basis | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | The source publishes synchronous sampling choices of 16, 32, 64, 128, 256, 512 and 1048 samples/revolution; no single fixed time-domain sample rate is stated. |
| quantity_specification | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Portable VC-8000-based data-acquisition system; removable 32 GB SD and optional 256 GB SSD; environmental range −20…+65 °C and 5–95% RH non-condensing. |
| Accuracy (% FSO) | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | 0.3 % |
| Interfaces | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | ethernet |
| Status | Active | Active | Active | Active | Active | Active | Active |
| Datasheet | PDF — C107835.001 (opens in a new tab) | PDF — C107836.001 (opens in a new tab) | PDF — C107836.002 (opens in a new tab) | PDF — C107836.003 (opens in a new tab) | PDF — C107836.004 (opens in a new tab) | PDF — C107836.0045 (opens in a new tab) |
The industries we serve
Frequently asked questions
Answers to the most common questions about our products and services
It is a portable vibration-analysis and temporary-monitoring system for rotating and reciprocating machinery, such as during startup, shutdown or after maintenance. It uses VC-8000 monitoring modules and SETPOINT CMS.
The documented configurations provide 4–24 channels. Each UMM supports up to 4 inputs for compatible sensors or process signals, according to configuration.
No. It can store data locally without a connected computer, or stream to an external computer or AVEVA PI. SETPOINT CMS provides viewing and diagnostics.
Compatible protection-system buffered outputs can connect through BNC and the documented cabling. Match module input mode and impedance to the signal type.
The portable setup software does not provide many protection functions, including relays. For protection-system use, the manufacturer specifies the VC-8000 setup and maintenance software and manual.