LAN-XI 3160 Input/Output Module Data acquisition systems

LAN-XI 3160 Input/Output Module: data acquisition systems by HBK.

Visit the HBK site (opens in a new tab)

Shared technical specifications for the series

Properties every model in the series has. What differs is in the models table below.

Range across models

The span covered by the models of the series together — not the range of each model.

Range across the models of LAN-XI 3160 Input/Output Module
ADC sampling rate 131000 samples/s
תחום כניסה במתח שיא 10 V
שגיאת אמפליטודה ב-dB 0.05 dB
DAQ input RMS noise 0.000004 V
Number of measurement channels 2–4

Models in the series

One column per model: what differs between the models of the series.

Models of LAN-XI 3160 Input/Output Module compared by parameter
Parameter -3160-A-022-R eli-m-0eb889e26c8aebda9a832d4d -3160-A-022-X eli-m-e1ada4971dc13eae3c54cc55 -3160-A-042-R eli-m-40ec9e157da021a39dd539d0 -3160-A-042-X eli-m-53eda72c0265005c511b04fe
ADC sampling rate 131000 samples/s 131000 samples/s 131000 samples/s 131000 samples/s
תחום כניסה במתח שיא 31.6 V 31.6 V 31.6 V 10 V
שגיאת אמפליטודה ב-dB 0.01 dB 0.05 dB 0.01 dB 0.05 dB
DAQ input RMS noise Maximum rate with a compatible controller Not specified Not specified Not specified Not specified
source_controller_shock_resistance_test_g 100 g 100 g 100 g 100 g
quantity_specification Inputs: Standardized voltage (+/- 10V), IEPE / CCLD, 200V condensor microphones; Outputs: Voltage (+/- 10V); Housing: Frame; Interfaces: TCP/IP Inputs: Standardized voltage (+/- 10V), IEPE / CCLD, 200V condensor microphones; Outputs: Voltage (+/- 10V); Housing: Frame; Interfaces: TCP/IP Inputs: Standardized voltage (+/- 10V), IEPE / CCLD, 200V condensor microphones; Outputs: Voltage (+/- 10V); Housing: Frame; Interfaces: TCP/IP Inputs: Standardized voltage (+/- 10V), IEPE / CCLD, 200V condensor microphones; Outputs: Voltage (+/- 10V); Housing: Frame; Interfaces: TCP/IP
Operating temperature -10–55 °C -10–55 °C -10–55 °C -10–55 °C
Protection class (DIN EN 60529) ip31 ip31 ip31 ip31
Number of measurement channels 2 2 4 4
Storage temperature -25–70 °C -25–70 °C -25–70 °C -25–70 °C
source_controller_magnetic_field_immunity_am_per_m EN/IEC 61000-4-8, 30 A/m EN/IEC 61000-4-8, 30 A/m EN/IEC 61000-4-8, 30 A/m EN/IEC 61000-4-8, 30 A/m
ADC resolution 24 bit 24 bit 24 bit 24 bit
source_linearity_basis Accuracy depends on the selected input and range. Accuracy depends on the selected input and range. Accuracy depends on the selected input and range. Accuracy depends on the selected input and range.
adc_converter_count 2 2 2 2
source_repeatability_basis System repeatability depends on the configured transducer, excitation, range, synchronization and calibration. System repeatability depends on the configured transducer, excitation, range, synchronization and calibration. System repeatability depends on the configured transducer, excitation, range, synchronization and calibration. System repeatability depends on the configured transducer, excitation, range, synchronization and calibration.
Interfaces ethernet ethernet ethernet ethernet
Frequency response 0–51200 Hz 0–51200 Hz 0–51200 Hz 0–51200 Hz
data_transfer_bits 24 bit 24 bit 24 bit 24 bit
source_sampling_rate_basis Official indexed maximum sample-rate selection: 131,000 Hz. Official indexed maximum sample-rate selection: 131,000 Hz. Official indexed maximum sample-rate selection: 131,000 Hz. Official indexed maximum sample-rate selection: 131,000 Hz.
Status Active Active Active Active

The industries we serve

Frequently asked questions

Answers to the most common questions about our products and services

It combines measurement inputs and generator outputs for tests that excite a system and measure its response.

The source lists either two inputs and two outputs, or four inputs and two outputs. Select by model code.

No. The table lists UA-2100-022 for 3160-A-022-R and UA-3100-042 for 3160-A-042-R. Connector and channel counts follow the configuration.

The brochure specifies DC to 51.2 kHz for the described input and output channels. This is not the system sampling rate.

The manufacturer identifies excitation-based applications such as audio and electroacoustic testing. Select connections and signal levels for the device under test.

Didn't find the answer you were looking for?

Talk to an expert

More information

Get a quote or advice

Tell us what you need and an engineer will come back to you.

Request a quote for this product
What would you like to ask for?

Email or phone — one of them is enough

Email or phone — one of them is enough

0 of 500 words