Skip to content

capaNCDT CSE/HT Capacitive

capaNCDT CSE/HT: sensors and measurement devices by Micro-Epsilon for capacitive.

Download the datasheet (opens in a new tab) This series on the Micro-Epsilon site (opens in a new tab)

Shared technical specifications for the series

Properties every model in the series has. What differs is in the models table below.

Range across models

The span covered by the models of the series together — not the range of each model.

Range across the models of capaNCDT CSE/HT
Measuring window 0–20 mm
Resolution 0.01–0.1 µm
Linearity 0.5–7 µm
active_area_published_size 5.7–18.2 mm
Operating temperature -50–800 °C
Measuring range 1–10 mm
Recommended target diameter 8–50 mm
Weight 0.062–0.47 kg
Accuracy 0.5–7 µm

Models in the series

One column per model: what differs between the models of the series.

Models of capaNCDT CSE/HT compared by parameter
Parameter CSE-1/HT/CA-1,0 eli-m-ce02b16a437211e070d2f31c CSE-10/HT/CA-1,0 eli-m-7445a96ce280be336eee850a CSE-2/HT/CA-1,0 eli-m-146ee944b22368f3875115f5 CSE-5/HT/CA-1,0 eli-m-65365637b1a2fc17b432136d
Storage temperature -50–200 °C -50–200 °C -50–200 °C -50–200 °C
source_linearity_basis Official sensor linearity from the current capaNCDT catalog; total measuring-channel linearity also includes the DT6228 + DL6228 controller contribution. Official sensor linearity from the current capaNCDT catalog; total measuring-channel linearity also includes the DT6238 + DL6228 controller contribution. Official sensor linearity from the current capaNCDT catalog; total measuring-channel linearity also includes the DT6238 + DL6228 controller contribution. Official sensor linearity from the current capaNCDT catalog; total measuring-channel linearity also includes the DT6228 + DL6228 controller contribution.
Measuring window 0–1 mm 0–20 mm 0–1 mm 0–5 mm
Interfaces ethercat ethernet ethernet ethercat
Resolution 0.01 µm 0.1 µm 0.02 µm 0.05 µm
Linearity 0.5 µm 7 µm 1 µm 3.5 µm
interface_specification 4-20mA 4-20mA 4-20mA 4-20mA
active_area_published_size 5.7 mm 18.2 mm 8.1 mm 12.9 mm
Operating temperature -50–800 °C -50–800 °C -50–200 °C -50–800 °C
Measuring range 2 mm 10 mm 1 mm 2.5 mm
source_temperature_stability_um_per_k -0.2 µm/K -2 µm/K -0.4 µm/K -1 µm/K
quantity_specification 0-1 mm model-level measuring interval 0-10 mm model-level measuring interval 0-2 mm model-level measuring interval 0-5 mm model-level measuring interval
source_sampling_rate_basis DL6228: 1 kHz bandwidth and 3.906 kSamples/s digital rate; optimized for CSE/HT sensors DL6228: 1 kHz bandwidth and 3.906 kSamples/s digital rate; optimized for CSE/HT sensors DL6228: 1 kHz bandwidth and 3.906 kSamples/s digital rate; optimized for CSE/HT sensors DL6228: 1 kHz bandwidth and 3.906 kSamples/s digital rate; optimized for CSE/HT sensors
Number of measurement channels 4 4 4 4
Recommended target diameter 8 mm 50 mm 14 mm 30 mm
Start of measuring range 0 mm 0 mm 0 mm 0 mm
Protection class (DIN EN 60529) ip40 ip40 ip40 ip40
source_recommended_mounting_position_mm 4.75 mm 30 mm 4.65 mm 9.1 mm
Weight 0.062 kg 0.47 kg 0.083 kg 0.225 kg
Contact Non-contact Non-contact Non-contact Non-contact
Accuracy 0.5 µm 7 µm 1 µm 3.5 µm
ADC sampling rate 1000 samples/s 1000 samples/s 1000 samples/s 1000 samples/s
Status Active Active Active Active
Datasheet PDF — CSE-1/HT/CA-1,0 (opens in a new tab) PDF — CSE-10/HT/CA-1,0 (opens in a new tab) PDF — CSE-2/HT/CA-1,0 (opens in a new tab) PDF — CSE-5/HT/CA-1,0 (opens in a new tab)

The industries we serve

Frequently asked questions

Answers to the most common questions about our products and services

No. The head and integral hot cable specify −50 to +800°C, while the connector is limited to 200°C. Controller and extension limits are separate.

The manufacturer recommends the DT6228/DT6238 path with a DL6228 demodulator for HT sensors. Select the basic module for the required interface too.

The table lists 1, 2, 5 and 10 mm, with separate target-size and linearity values. Extended range is not the same as nominal range.

It includes a 1 m hot cable and type B socket. An additional suitable cable can be used, preserving connector, length adjustment and each section’s temperature limits.

No. The table specifies IP40. Thermal capability and ingress protection are separate system requirements.

Didn't find the answer you were looking for?

Talk to an expert

More information

Get a quote or advice

Tell us what you need and an engineer will come back to you.

Request a quote for this product
What would you like to ask for?

Email or phone — one of them is enough

Email or phone — one of them is enough

0 of 500 words