Skip to content

Technical specification

Every engineering figure, laid out to scan quickly

Technical specification for CSE1.25
Measuring range 1.25 mm
Start of measuring range 0 mm
Measuring window 0–0.625 mm
Linearity 1.25 µm
Resolution 0.000375 µm
Recommended target diameter 10 mm
Minimum target diameter 8 mm
Interfaces ethernet
interface_specification Analog 0-10V
Number of measurement channels 2
Storage temperature -50–200 °C
Operating temperature -50–200 °C
Protection class (DIN EN 60529) ip40
Weight 0.008199999999999999 kg
quantity_specification 0-1.25 mm model-level measuring interval
source_temperature_stability_um_per_k -0.12 µm/K
source_recommended_mounting_position_mm 3.5 mm
active_area_published_size 6.5 mm
Measuring window 0–1.25 mm
Measuring range 2.05 mm
Resolution 0.025 µm
Measuring range 0.625 mm
Number of measurement channels 1
source_sampling_rate_basis DL6222: 20 kHz bandwidth; DT6222 digital rate 3.906 kSamples/s
source_sampling_rate_basis DL6220: 5 kHz bandwidth; DT6230 digital rate 3.906 kSamples/s
source_linearity_basis Official sensor linearity from the current capaNCDT catalog; total measuring-channel linearity also includes the DT6222 + DL6222 controller contribution.
source_sampling_rate_basis DT6120/IP: IP68 single-channel controller with 1 kHz analog bandwidth and up to 2 kSamples/s over RS485
source_sampling_rate_basis DT6112 high-speed controller: 20 kHz bandwidth
source_sampling_rate_basis DT6110/IP: IP68 single-channel controller with 1 kHz bandwidth
Measuring window 0–2.05 mm
source_sampling_rate_basis DL6530: 8.5 kHz bandwidth; DT6530 digital rate 7.8 kSamples/s at 4 channels or 3.9 kSamples/s at 8
Number of measurement channels 8
source_sampling_rate_basis DT6110: 1 kHz analog measurement bandwidth
Interfaces ethercat
source_linearity_basis Official sensor linearity from the current capaNCDT catalog; total measuring-channel linearity also includes the DT6230 + DL6230 controller contribution.
interface_specification 4-20mA
source_sampling_rate_basis DL6530: 8.5 kHz bandwidth in the official maximum-two-channel DT6530 base system
source_linearity_basis Official sensor linearity from the current capaNCDT catalog; total measuring-channel linearity also includes the DT6240 + DL6230 controller contribution.
source_linearity_basis Official sensor linearity from the current capaNCDT catalog; total measuring-channel linearity also includes the DT6110/IP controller contribution.
source_linearity_basis Official sensor linearity from the current capaNCDT catalog; total measuring-channel linearity also includes the DT6238 + DL6228 controller contribution.
source_linearity_basis Official sensor linearity from the current capaNCDT catalog; total measuring-channel linearity also includes the DT6530 (2-channel base) + DL6510 + CPM6011 controller contribution.
Number of measurement channels 4
source_linearity_basis Official sensor linearity from the current capaNCDT catalog; total measuring-channel linearity also includes the DT6220 + DL6230 controller contribution.
source_linearity_basis Official sensor linearity from the current capaNCDT catalog; total measuring-channel linearity also includes the DT6240 + DL6220 controller contribution.
source_linearity_basis Official sensor linearity from the current capaNCDT catalog; total measuring-channel linearity also includes the DT6230 + DL6220 controller contribution.
interface_specification RS422 / RS485
source_linearity_basis Official sensor linearity from the current capaNCDT catalog; total measuring-channel linearity also includes the DT6530 (2-channel base) + DL6510 + CP6001 controller contribution.
source_sampling_rate_basis DL6228: 1 kHz bandwidth and 3.906 kSamples/s digital rate; optimized for CSE/HT sensors
source_linearity_basis Official sensor linearity from the current capaNCDT catalog; total measuring-channel linearity also includes the DT6120 controller contribution.
source_sampling_rate_basis DT6120: 1 kHz analog bandwidth; up to 2 kSamples/s over RS485
source_sampling_rate_basis DL6230: 5 kHz bandwidth; DT6220 digital rate 3.906 kSamples/s
source_sampling_rate_basis DL6510 with CPM6011: 8.5 kHz bandwidth in the official maximum-two-channel DT6530 base system
source_linearity_basis Official sensor linearity from the current capaNCDT catalog; total measuring-channel linearity also includes the DT6110 controller contribution.
source_sampling_rate_basis DL6230: 5 kHz bandwidth; DT6240 digital rate 3.906 kSamples/s
Interfaces profinet
source_sampling_rate_basis DL6220: 5 kHz bandwidth; DT6240 digital rate 3.906 kSamples/s
source_sampling_rate_basis DL6510 with CPM6011: 8.5 kHz bandwidth in the official maximum-eight-channel DT6530 base system
source_linearity_basis Official sensor linearity from the current capaNCDT catalog; total measuring-channel linearity also includes the DT6530 (8-channel base) + DL6530 controller contribution.
source_linearity_basis Official sensor linearity from the current capaNCDT catalog; total measuring-channel linearity also includes the DT6530 (2-channel base) + DL6530 controller contribution.
source_linearity_basis Official sensor linearity from the current capaNCDT catalog; total measuring-channel linearity also includes the DT6228 + DL6228 controller contribution.
source_sampling_rate_basis DL6510 with CP6001: 8.5 kHz bandwidth in the official maximum-eight-channel DT6530 base system
source_linearity_basis Official sensor linearity from the current capaNCDT catalog; total measuring-channel linearity also includes the DT6530 (8-channel base) + DL6510 + CP6001 controller contribution.
source_sampling_rate_basis DL6230: 5 kHz bandwidth; DT6230 digital rate 3.906 kSamples/s
source_linearity_basis Official sensor linearity from the current capaNCDT catalog; total measuring-channel linearity also includes the DT6220 + DL6220 controller contribution.
source_sampling_rate_basis DL6220: 5 kHz bandwidth; DT6220 digital rate 3.906 kSamples/s
source_linearity_basis Official sensor linearity from the current capaNCDT catalog; total measuring-channel linearity also includes the DT6120/IP controller contribution.
source_linearity_basis Official sensor linearity from the current capaNCDT catalog; total measuring-channel linearity also includes the DT6530 (8-channel base) + DL6510 + CPM6011 controller contribution.
source_sampling_rate_basis DL6510 with CP6001: 8.5 kHz bandwidth in the official maximum-two-channel DT6530 base system
source_linearity_basis Official sensor linearity from the current capaNCDT catalog; total measuring-channel linearity also includes the DT6112 controller contribution.
Contact Non-contact
Request a quote for this product

Compatible system components

Controllers

  • DT6110 eli-m-3a9a07a0e16c8d276da5c3ec Required
  • DT6112 eli-m-363afdc0101726a3c7386066 Required
  • DT6120 eli-m-d469830ad426a1ff0a6d310c Required
  • DT6110/IP eli-m-bb97255d2237f1b4fead83d4 Required
  • DT6120/IP eli-m-6bd760f9ed329b48dd8bb009 Required

Compatible accessories

Cables

  • CCg eli-m-2de7a3194142736f2c7ea2c3
  • CCg/PT eli-m-e21071f22bbcd9f1682ff75b
  • CCm eli-m-8b9f829350510ac2ee7404c4
  • CCo eli-m-f56e9667458330d1138ce5d3
  • PC6200-x/4 eli-m-b0e46ffb0598fbe6a82afc41
  • SC6000-x eli-m-93680f9f0a413b9c4b69087f
  • SCACx/5 configurable component family eli-s-63090a88954ac684d10c1303 Only for source configuration configuration-1970628c3be34cbc81b74d45: CSE1.25; selected configuration must be matched before display.
  • SCACx/6 configurable component family eli-s-2707dbe76cd43e02ff56da8d Only for source configuration configuration-6ba3068980694e1d1b144ed2: CSE1.25; selected configuration must be matched before display.
  • SCACx/6/IP configurable component family eli-s-e1a5c0e60bcd87ef2645a09d Only for source configuration configuration-c1b5783195b32c93e47f57b3: CSE1.25; selected configuration must be matched before display.
  • SCACx/4 configurable component family eli-s-0ff9e5d0db5c61bbad7d6e8e Only for source configuration configuration-786159aa6ab091435e64ca0c: CSE1.25; selected configuration must be matched before display.
  • CAx configurable component family eli-s-8a1cf8c350120d89edfded32 Only for source configuration configuration-db8cefbd86201c99e6c3180b: CSE1.25; selected configuration must be matched before display.

Power supplies

Mounting

  • MA-CS-2-C eli-m-22f789295888f8bd5ac34a87 Optional
  • MA-CS3 eli-m-0ece2dadfcb97ff52381f79f Optional

Accessories

  • 0323050 eli-m-a0150f88c95dbe5fcec40b9d Optional
  • 0323346 eli-m-6b4570e12399777d844bcbe8 Optional
  • 0323349 eli-m-d12e7275de50ef53acbc6abe Optional

Complementary products

  • IF1032/ETH eli-m-9f23885a1bd1bd049fa826c5 Optional
  • CP6001 eli-m-ee14179d45127fbe4a5bb59d Optional
  • CMP6011 eli-m-48dfabeb6adde90890f548dd Optional

The industries we serve

Get a quote or advice

Tell us what you need and an engineer will come back to you.

Request a quote for this product
What would you like to ask for?

Email or phone — one of them is enough

Email or phone — one of them is enough

0 of 500 words