capaNCDT CSE Capacitive
capaNCDT CSE: sensors and measurement devices by Micro-Epsilon for capacitive.
Download the datasheet (opens in a new tab) This series on the Micro-Epsilon site (opens in a new tab)
Shared technical specifications for the series
Properties every model in the series has. What differs is in the models table below.
Range across models
The span covered by the models of the series together — not the range of each model.
| Measuring range | 0.05–3 mm |
|---|---|
| Measuring window | 0–1.5 mm |
| Resolution | 0.00003–0.06 µm |
| Number of measurement channels | 1–8 |
| Linearity | 0.25–3 µm |
| active_area_published_size | 1.8–9 mm |
| Recommended target diameter | 3–20 mm |
| Weight | 0.002–0.05 kg |
| Accuracy | 0.25–3 µm |
| ADC sampling rate | 1000–20000 samples/s |
| Minimum target diameter | 6–8 mm |
Models in the series
One column per model: what differs between the models of the series.
| Parameter | CSE01-CAm1,4 eli-m-7414ad52f4625ac4a321b607 | CSE025-CAm1,4 eli-m-8e70a37bf33d8c6d664e0f9d | CSE05 eli-m-586273316d6a601385943f78 | CSE1 eli-m-169ae1c941488de693285288 | CSE1.25 eli-m-b765b5e6fe4c753d97f628b5 | CSE2 eli-m-174db505874954d94c46b499 | CSE2 (כיול לינאריות משופר) eli-m-37ebe57f18ec3bba5698f303 | CSE3 eli-m-ff779d3fd9f3a408b773c3b4 |
|---|---|---|---|---|---|---|---|---|
| interface_specification | Analog 0-10V | Analog 0-10V | Analog 0-10V | Analog 0-10V | Analog 0-10V | 4-20mA | Not specified | Analog 0-10V |
| Measuring range | 0.05 mm | 0.125 mm | 1 mm | 2 mm | 1.25 mm | 1 mm | Not specified | 3 mm |
| Measuring window | 0–0.1 mm | 0–0.5 mm | 0–0.5 mm | 0–0.5 mm | 0–0.625 mm | 0–1 mm | Not specified | 0–1.5 mm |
| Start of measuring range | 0 mm | 0 mm | 0 mm | 0 mm | 0 mm | 0 mm | Not specified | 0 mm |
| Resolution | 3e-05 µm | 7.499999999999999e-05 µm | 0.01 µm | 0.0003 µm | 0.000375 µm | 0.0005999999999999999 µm | Not specified | 0.06 µm |
| Protection class (DIN EN 60529) | ip40 | ip40 | ip40 | ip40 | ip40 | ip40 | ip40 | ip40 |
| Interfaces | ethercat | ethercat | ethernet | ethernet | ethernet | profinet | Not specified | ethercat |
| Number of measurement channels | 8 | 4 | 1 | 1 | 2 | 2 | 1 | 4 |
| Linearity | 0.3 µm | 0.375 µm | 0.25 µm | 2 µm | 1.25 µm | 2 µm | Not specified | 3 µm |
| active_area_published_size | 1.8 mm | 2.9 mm | 3.9 mm | 5.7 mm | 6.5 mm | 8 mm | Not specified | 9 mm |
| Recommended target diameter | 3 mm | 4 mm | 6 mm | 8 mm | 10 mm | 14 mm | Not specified | 20 mm |
| source_recommended_mounting_position_mm | 2.5 mm | 1.2 mm | 3.0 mm | 3.0 mm | 3.5 mm | 3.5 mm | Not specified | 4.5 mm |
| Weight | 0.026 kg | 0.027 kg | 0.002 kg | 0.0035 kg | 0.008199999999999999 kg | 0.02 kg | Not specified | 0.05 kg |
| source_linearity_basis | Official sensor linearity from the current capaNCDT catalog; total measuring-channel linearity also includes the DT6240 + DL6220 controller contribution. | Official sensor linearity from the current capaNCDT catalog; total measuring-channel linearity also includes the DT6222 + DL6222 controller contribution. | Official sensor linearity from the current capaNCDT catalog; total measuring-channel linearity also includes the DT6230 + DL6230 controller contribution. | Official sensor linearity from the current capaNCDT catalog; total measuring-channel linearity also includes the DT6120 controller contribution. | Official sensor linearity from the current capaNCDT catalog; total measuring-channel linearity also includes the DT6222 + DL6222 controller contribution. | Official sensor linearity from the current capaNCDT catalog; total measuring-channel linearity also includes the DT6530 (8-channel base) + DL6510 + CPM6011 controller contribution. | Not specified | Official sensor linearity from the current capaNCDT catalog; total measuring-channel linearity also includes the DT6240 + DL6220 controller contribution. |
| Operating temperature | -50–200 °C | -50–200 °C | -50–200 °C | -50–200 °C | -50–200 °C | -50–200 °C | -50–200 °C | -50–200 °C |
| source_temperature_stability_um_per_k | -0.025 µm/K | -0.025 µm/K | -0.02 µm/K | -0.02 µm/K | -0.12 µm/K | -0.16 µm/K | Not specified | -0.18 µm/K |
| source_sampling_rate_basis | DL6530: 8.5 kHz bandwidth; DT6530 digital rate 7.8 kSamples/s at 4 channels or 3.9 kSamples/s at 8 | DL6510 with CP6001: 8.5 kHz bandwidth in the official maximum-eight-channel DT6530 base system | DL6220: 5 kHz bandwidth; DT6220 digital rate 3.906 kSamples/s | DL6220: 5 kHz bandwidth; DT6230 digital rate 3.906 kSamples/s | DL6222: 20 kHz bandwidth; DT6222 digital rate 3.906 kSamples/s | DL6530: 8.5 kHz bandwidth in the official maximum-two-channel DT6530 base system | Not specified | DL6228: 1 kHz bandwidth and 3.906 kSamples/s digital rate; optimized for CSE/HT sensors |
| quantity_specification | 0-0.1 mm model-level measuring interval | 0-0.25 mm model-level measuring interval | 0-0.5 mm model-level measuring interval | 0-1 mm model-level measuring interval | 0-1.25 mm model-level measuring interval | 0-2 mm model-level measuring interval | Not specified | 0-3 mm model-level measuring interval |
| Storage temperature | -50–200 °C | -50–200 °C | -50–200 °C | -50–200 °C | -50–200 °C | -50–200 °C | Not specified | -50–200 °C |
| Contact | Non-contact | Non-contact | Non-contact | Non-contact | Non-contact | Non-contact | Non-contact | Non-contact |
| Accuracy | 0.3 µm | 0.375 µm | 0.25 µm | 2 µm | 1.25 µm | 2 µm | Not specified | 3 µm |
| ADC sampling rate | 8500 samples/s | 1000 samples/s | 1000 samples/s | 20000 samples/s | 5000 samples/s | 2000 samples/s | Not specified | 5000 samples/s |
| Minimum target diameter | Not specified | Not specified | 6 mm | 8 mm | 8 mm | Not specified | Not specified | Not specified |
| Status | Active | Active | Active | Active | Active | Active | Active | Active |
| Datasheet | PDF — CSE01-CAm1,4 (opens in a new tab) | PDF — CSE025-CAm1,4 (opens in a new tab) | PDF — CSE05 (opens in a new tab) | PDF — CSE1 (opens in a new tab) | PDF — CSE1.25 (opens in a new tab) | PDF — CSE2 (opens in a new tab) | PDF — CSE2 (כיול לינאריות משופר) (opens in a new tab) | PDF — CSE3 (opens in a new tab) |
The industries we serve
Frequently asked questions
Answers to the most common questions about our products and services
CSE is a particularly compact cylindrical head for confined installation spaces. Separate models cover nominal spans from 0.1 to 3 mm.
No. Some models include a cable; others use a triaxial socket. Type B or C also depends on model, so select the exact cable configuration.
The manufacturer describes point clamping with a plastic screw or circumferential clamping. Specifications reference the recommended circumferential position, with heat buildup considered.
No. The footnote references DT6530, 2 Hz static and 8.5 kHz dynamic bandwidth, and the specified standard cable. Retain those conditions.
No. The CSE head remains IP40 as specified. Controller protection does not change head or connection ratings.