Skip to content

Shared technical specifications for the series

Properties every model in the series has. What differs is in the models table below.

Range across models

The span covered by the models of the series together — not the range of each model.

Range across the models of capaNCDT CSE
Measuring range 0.05–3 mm
Measuring window 0–1.5 mm
Resolution 0.00003–0.06 µm
Number of measurement channels 1–8
Linearity 0.25–3 µm
active_area_published_size 1.8–9 mm
Recommended target diameter 3–20 mm
Weight 0.002–0.05 kg
Accuracy 0.25–3 µm
ADC sampling rate 1000–20000 samples/s
Minimum target diameter 6–8 mm

Models in the series

One column per model: what differs between the models of the series.

Models of capaNCDT CSE compared by parameter
Parameter CSE01-CAm1,4 eli-m-7414ad52f4625ac4a321b607 CSE025-CAm1,4 eli-m-8e70a37bf33d8c6d664e0f9d CSE05 eli-m-586273316d6a601385943f78 CSE1 eli-m-169ae1c941488de693285288 CSE1.25 eli-m-b765b5e6fe4c753d97f628b5 CSE2 eli-m-174db505874954d94c46b499 CSE2 (כיול לינאריות משופר) eli-m-37ebe57f18ec3bba5698f303 CSE3 eli-m-ff779d3fd9f3a408b773c3b4
interface_specification Analog 0-10V Analog 0-10V Analog 0-10V Analog 0-10V Analog 0-10V 4-20mA Not specified Analog 0-10V
Measuring range 0.05 mm 0.125 mm 1 mm 2 mm 1.25 mm 1 mm Not specified 3 mm
Measuring window 0–0.1 mm 0–0.5 mm 0–0.5 mm 0–0.5 mm 0–0.625 mm 0–1 mm Not specified 0–1.5 mm
Start of measuring range 0 mm 0 mm 0 mm 0 mm 0 mm 0 mm Not specified 0 mm
Resolution 3e-05 µm 7.499999999999999e-05 µm 0.01 µm 0.0003 µm 0.000375 µm 0.0005999999999999999 µm Not specified 0.06 µm
Protection class (DIN EN 60529) ip40 ip40 ip40 ip40 ip40 ip40 ip40 ip40
Interfaces ethercat ethercat ethernet ethernet ethernet profinet Not specified ethercat
Number of measurement channels 8 4 1 1 2 2 1 4
Linearity 0.3 µm 0.375 µm 0.25 µm 2 µm 1.25 µm 2 µm Not specified 3 µm
active_area_published_size 1.8 mm 2.9 mm 3.9 mm 5.7 mm 6.5 mm 8 mm Not specified 9 mm
Recommended target diameter 3 mm 4 mm 6 mm 8 mm 10 mm 14 mm Not specified 20 mm
source_recommended_mounting_position_mm 2.5 mm 1.2 mm 3.0 mm 3.0 mm 3.5 mm 3.5 mm Not specified 4.5 mm
Weight 0.026 kg 0.027 kg 0.002 kg 0.0035 kg 0.008199999999999999 kg 0.02 kg Not specified 0.05 kg
source_linearity_basis Official sensor linearity from the current capaNCDT catalog; total measuring-channel linearity also includes the DT6240 + DL6220 controller contribution. Official sensor linearity from the current capaNCDT catalog; total measuring-channel linearity also includes the DT6222 + DL6222 controller contribution. Official sensor linearity from the current capaNCDT catalog; total measuring-channel linearity also includes the DT6230 + DL6230 controller contribution. Official sensor linearity from the current capaNCDT catalog; total measuring-channel linearity also includes the DT6120 controller contribution. Official sensor linearity from the current capaNCDT catalog; total measuring-channel linearity also includes the DT6222 + DL6222 controller contribution. Official sensor linearity from the current capaNCDT catalog; total measuring-channel linearity also includes the DT6530 (8-channel base) + DL6510 + CPM6011 controller contribution. Not specified Official sensor linearity from the current capaNCDT catalog; total measuring-channel linearity also includes the DT6240 + DL6220 controller contribution.
Operating temperature -50–200 °C -50–200 °C -50–200 °C -50–200 °C -50–200 °C -50–200 °C -50–200 °C -50–200 °C
source_temperature_stability_um_per_k -0.025 µm/K -0.025 µm/K -0.02 µm/K -0.02 µm/K -0.12 µm/K -0.16 µm/K Not specified -0.18 µm/K
source_sampling_rate_basis DL6530: 8.5 kHz bandwidth; DT6530 digital rate 7.8 kSamples/s at 4 channels or 3.9 kSamples/s at 8 DL6510 with CP6001: 8.5 kHz bandwidth in the official maximum-eight-channel DT6530 base system DL6220: 5 kHz bandwidth; DT6220 digital rate 3.906 kSamples/s DL6220: 5 kHz bandwidth; DT6230 digital rate 3.906 kSamples/s DL6222: 20 kHz bandwidth; DT6222 digital rate 3.906 kSamples/s DL6530: 8.5 kHz bandwidth in the official maximum-two-channel DT6530 base system Not specified DL6228: 1 kHz bandwidth and 3.906 kSamples/s digital rate; optimized for CSE/HT sensors
quantity_specification 0-0.1 mm model-level measuring interval 0-0.25 mm model-level measuring interval 0-0.5 mm model-level measuring interval 0-1 mm model-level measuring interval 0-1.25 mm model-level measuring interval 0-2 mm model-level measuring interval Not specified 0-3 mm model-level measuring interval
Storage temperature -50–200 °C -50–200 °C -50–200 °C -50–200 °C -50–200 °C -50–200 °C Not specified -50–200 °C
Contact Non-contact Non-contact Non-contact Non-contact Non-contact Non-contact Non-contact Non-contact
Accuracy 0.3 µm 0.375 µm 0.25 µm 2 µm 1.25 µm 2 µm Not specified 3 µm
ADC sampling rate 8500 samples/s 1000 samples/s 1000 samples/s 20000 samples/s 5000 samples/s 2000 samples/s Not specified 5000 samples/s
Minimum target diameter Not specified Not specified 6 mm 8 mm 8 mm Not specified Not specified Not specified
Status Active Active Active Active Active Active Active Active
Datasheet PDF — CSE01-CAm1,4 (opens in a new tab) PDF — CSE025-CAm1,4 (opens in a new tab) PDF — CSE05 (opens in a new tab) PDF — CSE1 (opens in a new tab) PDF — CSE1.25 (opens in a new tab) PDF — CSE2 (opens in a new tab) PDF — CSE2 (כיול לינאריות משופר) (opens in a new tab) PDF — CSE3 (opens in a new tab)

The industries we serve

Frequently asked questions

Answers to the most common questions about our products and services

CSE is a particularly compact cylindrical head for confined installation spaces. Separate models cover nominal spans from 0.1 to 3 mm.

No. Some models include a cable; others use a triaxial socket. Type B or C also depends on model, so select the exact cable configuration.

The manufacturer describes point clamping with a plastic screw or circumferential clamping. Specifications reference the recommended circumferential position, with heat buildup considered.

No. The footnote references DT6530, 2 Hz static and 8.5 kHz dynamic bandwidth, and the specified standard cable. Retain those conditions.

No. The CSE head remains IP40 as specified. Controller protection does not change head or connection ratings.

Didn't find the answer you were looking for?

Talk to an expert

More information

Get a quote or advice

Tell us what you need and an engineer will come back to you.

Request a quote for this product
What would you like to ask for?

Email or phone — one of them is enough

Email or phone — one of them is enough

0 of 500 words