Skip to content

Shared technical specifications for the series

Properties every model in the series has. What differs is in the models table below.

Range across models

The span covered by the models of the series together — not the range of each model.

Range across the models of capaNCDT CSG
Measuring range 0.25–1 mm
Measuring window 0–2 mm
Operating temperature -50–150 °C
Resolution 0.00015–0.02 µm
Linearity 0.5–2 µm
Recommended target width 9.9–12 mm
Recommended target height 10–15 mm
active_area_width 4–15 mm
active_area_height 3–6.5 mm
Weight 0.077–0.13 kg
Storage temperature -50–100 °C
Number of measurement channels 1–8
Accuracy 0.5–2 µm
ADC sampling rate 1000–8500 samples/s

Models in the series

One column per model: what differs between the models of the series.

Models of capaNCDT CSG compared by parameter
Parameter CSG-0.5/CRg2.0 eli-m-ff9eb3527d5198762f7cf52a CSG-1/90/CRg-2.0 eli-m-be149a6fa53d5885f449694a CSG-1/CRg2.0 eli-m-3000fdc71de3dde551507480 CSG0,50-CAm2,0 eli-m-d5b655eca48e077ca43a7c09 CSG1,00-CAm2,0 eli-m-d6157abb38b3536f550f9db3
Measuring range 0.25 mm 1 mm 1 mm 0.25 mm 0.5 mm
interface_specification Analog 0-10V Analog 0-10V Analog 0-10V 4-20mA Analog 0-10V
Measuring window 0–0.25 mm 0–2 mm 0–1 mm 0–0.5 mm 0–0.5 mm
Operating temperature -20–100 °C -20–80 °C -20–150 °C -50–100 °C -50–100 °C
source_gap_measurement_mode Double-sided gap Double-sided gap Double-sided gap two-sided gap measurement Double-sided gap
Protection class (DIN EN 60529) ip40 ip40 ip40 ip40 ip40
source_temperature_stability_um_per_k -0.2 µm/K -0.2 µm/K -0.2 µm/K -0.08 µm/K -0.1 µm/K
Start of measuring range 0 mm 0 mm 0 mm 0 mm 0 mm
source_sensor_form Flat / strip / PCB Flat / strip / PCB Flat / strip / PCB Flat / strip / PCB Flat / strip / PCB
Resolution 0.01 µm 0.02 µm 0.0003 µm 0.00015 µm 0.0003 µm
source_sampling_rate_basis DT6120: 1 kHz analog bandwidth; up to 2 kSamples/s over RS485 DT6120/IP: IP68 single-channel controller with 1 kHz analog bandwidth and up to 2 kSamples/s over RS485 DT6120: 1 kHz analog bandwidth; up to 2 kSamples/s over RS485 DL6228: 1 kHz bandwidth and 3.906 kSamples/s digital rate; optimized for CSE/HT sensors DL6220: 5 kHz bandwidth; DT6230 digital rate 3.906 kSamples/s
active_area_length 200 mm 200 mm 200 mm 200 mm 200 mm
Linearity 1 µm 2 µm 2 µm 0.5 µm 1 µm
Interfaces ethercat ethercat ethernet ethernet ethernet
Recommended target width 10 mm 10 mm 12 mm 9.9 mm 9.9 mm
Recommended target height 10 mm 10 mm 12 mm 15 mm 15 mm
active_area_width 15 mm 15 mm 4 mm 4.3 mm 15 mm
active_area_height 3 mm 5.1 mm 6.5 mm 3 mm 4.2 mm
quantity_specification 0-0.5 mm sensor range; effective gap range is 0.9-2 mm 0-1 mm sensor range; effective gap range is 0.9-2.9 mm 0-1 mm sensor range; effective gap range is 0.9-2.9 mm 0-0.5 mm sensor range; effective gap range is 0.9-1.9 mm 0-1 mm sensor range; effective gap range is 0.9-2.9 mm
source_linearity_basis Official sensor linearity from the current capaNCDT catalog; total measuring-channel linearity also includes the DT6530 (2-channel base) + DL6510 + CP6001 controller contribution. Official sensor linearity from the current capaNCDT catalog; total measuring-channel linearity also includes the DT6120/IP controller contribution. Official sensor linearity from the current capaNCDT catalog; total measuring-channel linearity also includes the DT6530 (8-channel base) + DL6530 controller contribution. Official sensor linearity from the current capaNCDT catalog; total measuring-channel linearity also includes the DT6530 (2-channel base) + DL6530 controller contribution. Official sensor linearity from the current capaNCDT catalog; total measuring-channel linearity also includes the DT6530 (2-channel base) + DL6510 + CPM6011 controller contribution.
Weight 0.08 kg 0.13 kg 0.09 kg 0.077 kg 0.077 kg
Storage temperature -20–100 °C -20–80 °C -20–80 °C -50–100 °C -50–100 °C
Number of measurement channels 1 4 1 1 8
Contact Non-contact Non-contact Non-contact Non-contact Non-contact
Accuracy 1 µm 2 µm 2 µm 0.5 µm 1 µm
ADC sampling rate 8500 samples/s 5000 samples/s 8500 samples/s 1000 samples/s 5000 samples/s
Status Active Active Active Active Active
Datasheet PDF — CSG-0.5/CRg2.0 (opens in a new tab) PDF — CSG-1/90/CRg-2.0 (opens in a new tab) PDF — CSG-1/CRg2.0 (opens in a new tab) PDF — CSG0,50-CAm2,0 (opens in a new tab) PDF — CSG1,00-CAm2,0 (opens in a new tab)

The industries we serve

Frequently asked questions

Answers to the most common questions about our products and services

CSG measures both sides and uses two distances to determine gap width. CSF measures one side and suits a fixed reference side or suitable portable measurement.

No. Measuring span and insertion clearance are different. The table specifies a required gap width of at least 0.9 mm; check the model geometry.

No. Certain model columns distinguish sensor and cable limits. Select for both limits of the exact model, not a family maximum.

Mount the appropriate section outside the gap, with the flexible part extending into it. Model-specific mounting uses surface clamping or M3 screws.

The manufacturer also describes an MD6-22 portable-controller arrangement with manual insertion. This differs from mounting for continuous measurement.

Didn't find the answer you were looking for?

Talk to an expert

More information

Get a quote or advice

Tell us what you need and an engineer will come back to you.

Request a quote for this product
What would you like to ask for?

Email or phone — one of them is enough

Email or phone — one of them is enough

0 of 500 words