capaNCDT CSG Capacitive
capaNCDT CSG: sensors and measurement devices by Micro-Epsilon for capacitive.
Download the datasheet (opens in a new tab) This series on the Micro-Epsilon site (opens in a new tab)
Shared technical specifications for the series
Properties every model in the series has. What differs is in the models table below.
Range across models
The span covered by the models of the series together — not the range of each model.
| Measuring range | 0.25–1 mm |
|---|---|
| Measuring window | 0–2 mm |
| Operating temperature | -50–150 °C |
| Resolution | 0.00015–0.02 µm |
| Linearity | 0.5–2 µm |
| Recommended target width | 9.9–12 mm |
| Recommended target height | 10–15 mm |
| active_area_width | 4–15 mm |
| active_area_height | 3–6.5 mm |
| Weight | 0.077–0.13 kg |
| Storage temperature | -50–100 °C |
| Number of measurement channels | 1–8 |
| Accuracy | 0.5–2 µm |
| ADC sampling rate | 1000–8500 samples/s |
Models in the series
One column per model: what differs between the models of the series.
| Parameter | CSG-0.5/CRg2.0 eli-m-ff9eb3527d5198762f7cf52a | CSG-1/90/CRg-2.0 eli-m-be149a6fa53d5885f449694a | CSG-1/CRg2.0 eli-m-3000fdc71de3dde551507480 | CSG0,50-CAm2,0 eli-m-d5b655eca48e077ca43a7c09 | CSG1,00-CAm2,0 eli-m-d6157abb38b3536f550f9db3 |
|---|---|---|---|---|---|
| Measuring range | 0.25 mm | 1 mm | 1 mm | 0.25 mm | 0.5 mm |
| interface_specification | Analog 0-10V | Analog 0-10V | Analog 0-10V | 4-20mA | Analog 0-10V |
| Measuring window | 0–0.25 mm | 0–2 mm | 0–1 mm | 0–0.5 mm | 0–0.5 mm |
| Operating temperature | -20–100 °C | -20–80 °C | -20–150 °C | -50–100 °C | -50–100 °C |
| source_gap_measurement_mode | Double-sided gap | Double-sided gap | Double-sided gap | two-sided gap measurement | Double-sided gap |
| Protection class (DIN EN 60529) | ip40 | ip40 | ip40 | ip40 | ip40 |
| source_temperature_stability_um_per_k | -0.2 µm/K | -0.2 µm/K | -0.2 µm/K | -0.08 µm/K | -0.1 µm/K |
| Start of measuring range | 0 mm | 0 mm | 0 mm | 0 mm | 0 mm |
| source_sensor_form | Flat / strip / PCB | Flat / strip / PCB | Flat / strip / PCB | Flat / strip / PCB | Flat / strip / PCB |
| Resolution | 0.01 µm | 0.02 µm | 0.0003 µm | 0.00015 µm | 0.0003 µm |
| source_sampling_rate_basis | DT6120: 1 kHz analog bandwidth; up to 2 kSamples/s over RS485 | DT6120/IP: IP68 single-channel controller with 1 kHz analog bandwidth and up to 2 kSamples/s over RS485 | DT6120: 1 kHz analog bandwidth; up to 2 kSamples/s over RS485 | DL6228: 1 kHz bandwidth and 3.906 kSamples/s digital rate; optimized for CSE/HT sensors | DL6220: 5 kHz bandwidth; DT6230 digital rate 3.906 kSamples/s |
| active_area_length | 200 mm | 200 mm | 200 mm | 200 mm | 200 mm |
| Linearity | 1 µm | 2 µm | 2 µm | 0.5 µm | 1 µm |
| Interfaces | ethercat | ethercat | ethernet | ethernet | ethernet |
| Recommended target width | 10 mm | 10 mm | 12 mm | 9.9 mm | 9.9 mm |
| Recommended target height | 10 mm | 10 mm | 12 mm | 15 mm | 15 mm |
| active_area_width | 15 mm | 15 mm | 4 mm | 4.3 mm | 15 mm |
| active_area_height | 3 mm | 5.1 mm | 6.5 mm | 3 mm | 4.2 mm |
| quantity_specification | 0-0.5 mm sensor range; effective gap range is 0.9-2 mm | 0-1 mm sensor range; effective gap range is 0.9-2.9 mm | 0-1 mm sensor range; effective gap range is 0.9-2.9 mm | 0-0.5 mm sensor range; effective gap range is 0.9-1.9 mm | 0-1 mm sensor range; effective gap range is 0.9-2.9 mm |
| source_linearity_basis | Official sensor linearity from the current capaNCDT catalog; total measuring-channel linearity also includes the DT6530 (2-channel base) + DL6510 + CP6001 controller contribution. | Official sensor linearity from the current capaNCDT catalog; total measuring-channel linearity also includes the DT6120/IP controller contribution. | Official sensor linearity from the current capaNCDT catalog; total measuring-channel linearity also includes the DT6530 (8-channel base) + DL6530 controller contribution. | Official sensor linearity from the current capaNCDT catalog; total measuring-channel linearity also includes the DT6530 (2-channel base) + DL6530 controller contribution. | Official sensor linearity from the current capaNCDT catalog; total measuring-channel linearity also includes the DT6530 (2-channel base) + DL6510 + CPM6011 controller contribution. |
| Weight | 0.08 kg | 0.13 kg | 0.09 kg | 0.077 kg | 0.077 kg |
| Storage temperature | -20–100 °C | -20–80 °C | -20–80 °C | -50–100 °C | -50–100 °C |
| Number of measurement channels | 1 | 4 | 1 | 1 | 8 |
| Contact | Non-contact | Non-contact | Non-contact | Non-contact | Non-contact |
| Accuracy | 1 µm | 2 µm | 2 µm | 0.5 µm | 1 µm |
| ADC sampling rate | 8500 samples/s | 5000 samples/s | 8500 samples/s | 1000 samples/s | 5000 samples/s |
| Status | Active | Active | Active | Active | Active |
| Datasheet | PDF — CSG-0.5/CRg2.0 (opens in a new tab) | PDF — CSG-1/90/CRg-2.0 (opens in a new tab) | PDF — CSG-1/CRg2.0 (opens in a new tab) | PDF — CSG0,50-CAm2,0 (opens in a new tab) | PDF — CSG1,00-CAm2,0 (opens in a new tab) |
The industries we serve
Frequently asked questions
Answers to the most common questions about our products and services
CSG measures both sides and uses two distances to determine gap width. CSF measures one side and suits a fixed reference side or suitable portable measurement.
No. Measuring span and insertion clearance are different. The table specifies a required gap width of at least 0.9 mm; check the model geometry.
No. Certain model columns distinguish sensor and cable limits. Select for both limits of the exact model, not a family maximum.
Mount the appropriate section outside the gap, with the flexible part extending into it. Model-specific mounting uses surface clamping or M3 screws.
The manufacturer also describes an MD6-22 portable-controller arrangement with manual insertion. This differs from mounting for continuous measurement.