Skip to content

capaNCDT CSHxFL Capacitive

capaNCDT CSHxFL: sensors and measurement devices by Micro-Epsilon for capacitive.

Download the datasheet (opens in a new tab) This series on the Micro-Epsilon site (opens in a new tab)

Shared technical specifications for the series

Properties every model in the series has. What differs is in the models table below.

Range across models

The span covered by the models of the series together — not the range of each model.

Range across the models of capaNCDT CSHxFL
Minimum target diameter 7–11 mm
active_area_published_size 2.6–10 mm
Number of measurement channels 1–4
Resolution 0.00006–0.06 µm
Linearity 0.08–1.5 µm
Measuring range 0.2–3 mm
Recommended target diameter 7–24 mm
Weight 0.028–0.037 kg
Measuring window 0–4 mm
Accuracy 0.08–1.5 µm
ADC sampling rate 1000–20000 samples/s

Models in the series

One column per model: what differs between the models of the series.

Models of capaNCDT CSHxFL compared by parameter
Parameter CSH-02FL-CRm1,4 eli-m-dadedbb886929b6ca0d2c790 CSH-05FL-CRm1,4 eli-m-c1bd47c6ac4f9d9998f67f89 CSH1,2FL-CRm1,4 eli-m-72d7d25981d3509acafa2f9e CSH1FL-CRm1,4 eli-m-b693c3e7ad6e9d40f6769ece CSH2FL-CRm1,4 eli-m-7319d7c56994db7eb4b9b63a CSH3FL-CRm1,4 eli-m-109375bd3f4da51f80d7be4a
Protection class (DIN EN 60529) ip40 ip40 ip40 ip40 ip40 ip40
Minimum target diameter 7 mm Not specified 11 mm 11 mm Not specified Not specified
Operating temperature -50–200 °C -50–200 °C -50–200 °C -50–200 °C -50–200 °C -50–200 °C
active_area_published_size 2.6 mm 4.1 mm 6.3 mm 5.7 mm 8.1 mm 10 mm
Storage temperature -50–200 °C -50–200 °C -50–200 °C -50–200 °C -50–200 °C -50–200 °C
Number of measurement channels 1 4 4 4 4 2
Resolution 6.000000000000001e-05 µm 0.00015 µm 0.00036 µm 0.0003 µm 0.0005999999999999999 µm 0.06 µm
interface_specification 4-20mA Analog 0-10V RS422 / RS485 Analog 0-10V Analog 0-10V 4-20mA
Linearity 0.08 µm 0.35 µm 1.2 µm 0.6 µm 0.6 µm 1.5 µm
Measuring range 0.2 mm 1 mm 2.4 mm 1 mm 2 mm 3 mm
source_sampling_rate_basis DL6510 with CP6001: 8.5 kHz bandwidth in the official maximum-eight-channel DT6530 base system DL6530: 8.5 kHz bandwidth; DT6530 digital rate 7.8 kSamples/s at 4 channels or 3.9 kSamples/s at 8 DL6530: 8.5 kHz bandwidth; DT6530 digital rate 7.8 kSamples/s at 4 channels or 3.9 kSamples/s at 8 DL6230: 5 kHz bandwidth; DT6240 digital rate 3.906 kSamples/s DT6112 high-speed controller: 20 kHz bandwidth DT6120/IP: IP68 single-channel controller with 1 kHz analog bandwidth and up to 2 kSamples/s over RS485
Interfaces ethernet ethercat ethercat ethernet profinet ethernet
Recommended target diameter 7 mm 7 mm 11 mm 11 mm 17 mm 24 mm
Start of measuring range 0 mm 0 mm 0 mm 0 mm 0 mm 0 mm
Weight 0.028 kg 0.028 kg 0.03 kg 0.03 kg 0.037 kg 0.037 kg
quantity_specification 0-0.2 mm model-level measuring interval 0-0.5 mm model-level measuring interval 0-1.2 mm model-level measuring interval 0-1 mm model-level measuring interval 0-2 mm model-level measuring interval 0-3 mm model-level measuring interval
Measuring window 0–0.2 mm 0–0.5 mm 0–1.2 mm 0–1 mm 0–4 mm 0–1.5 mm
source_linearity_basis Official sensor linearity from the current capaNCDT catalog; total measuring-channel linearity also includes the DT6530 (2-channel base) + DL6510 + CPM6011 controller contribution. Official sensor linearity from the current capaNCDT catalog; total measuring-channel linearity also includes the DT6110 controller contribution. Official sensor linearity from the current capaNCDT catalog; total measuring-channel linearity also includes the DT6530 (2-channel base) + DL6510 + CPM6011 controller contribution. Official sensor linearity from the current capaNCDT catalog; total measuring-channel linearity also includes the DT6530 (2-channel base) + DL6510 + CP6001 controller contribution. Official sensor linearity from the current capaNCDT catalog; total measuring-channel linearity also includes the DT6530 (2-channel base) + DL6530 controller contribution. Official sensor linearity from the current capaNCDT catalog; total measuring-channel linearity also includes the DT6220 + DL6230 controller contribution.
Contact Non-contact Non-contact Non-contact Non-contact Non-contact Non-contact
Accuracy 0.08 µm 0.35 µm 1.2 µm 0.6 µm 0.6 µm 1.5 µm
ADC sampling rate 5000 samples/s 1000 samples/s 8500 samples/s 2000 samples/s 20000 samples/s 5000 samples/s
Status Active Active Active Active Active Active
Datasheet PDF — CSH-02FL-CRm1,4 (opens in a new tab) PDF — CSH-05FL-CRm1,4 (opens in a new tab) PDF — CSH1,2FL-CRm1,4 (opens in a new tab) PDF — CSH1FL-CRm1,4 (opens in a new tab) PDF — CSH2FL-CRm1,4 (opens in a new tab) PDF — CSH3FL-CRm1,4 (opens in a new tab)

The industries we serve

Frequently asked questions

Answers to the most common questions about our products and services

Its flat geometry suits limited installation height. Separate models cover nominal spans from 0.2 to 3 mm.

Yes. The table provides different coefficients for front-side and rear-side mounting. Use the coefficient for the actual installation.

Depending on model, use M2 threads or through-holes for M2 screws, with top or bottom mounting. Follow the exact model drawing.

It specifies an integral 1.4 m cable with a type B connector. Use a compatible capaNCDT controller and assess head/controller performance together.

No. Match span, linearity, target size and mounting too. Tabulated resolution refers to specified bandwidth and controller conditions.

Didn't find the answer you were looking for?

Talk to an expert

More information

Get a quote or advice

Tell us what you need and an engineer will come back to you.

Request a quote for this product
What would you like to ask for?

Email or phone — one of them is enough

Email or phone — one of them is enough

0 of 500 words