DT3001-U4-A-SA
From the eddyNCDT 3001 series
eddyNCDT 3001: sensors and measurement devices by Micro-Epsilon for inductive (eddy current).
- Number of measurement channels
- 1
Technical specification
Every engineering figure, laid out to scan quickly
| Measuring range | 4 mm |
|---|---|
| Start of measuring range | 0.4 mm |
| End of measuring range | 4.4 mm |
| Working distance | 0.4–4.4 mm |
| Linearity | 28 µm |
| Resolution | 4 µm |
| Minimum target diameter | 48 mm |
| source_calibrated_target_material | "Aluminum" |
| Supply voltage | 12–32 V |
| Interfaces | ethercat |
| interface_specification | Digital I/O |
| Number of measurement channels | 1 |
| Storage temperature | -20–80 °C |
| Operating temperature | 0–70 °C |
| Protection class (DIN EN 60529) | ip67 |
| Upper cutoff frequency | 5000 Hz |
| source_sensor_shielding | "unshielded" |
| quantity_specification | 0-4 mm model-level measuring interval |
| Interfaces | ethernet |
| interface_specification | RS422 / RS485 |
| interface_specification | Analog 0-10V |
| interface_specification | 4-20mA |
| source_sampling_rate_basis | Integrated DT3001 electronics: 75 kSamples/s, 5 kHz bandwidth |
Compatible accessories
Power supplies
- PS2020 (2420062) eli-m-75d559684cc51453ffe276de
Complementary products
- IF1032/ETH eli-m-9f23885a1bd1bd049fa826c5
Cables
- PCx/5-M12 configurable component family eli-s-58d2ba937187973224f1636a Only for source configuration configuration-36898e372848693355136a6b: DT3001-U4-A-SA; selected configuration must be matched before display.; 5 m standard; longer and drag-chain variants are optional. Not a sensor-controller extension.
The industries we serve
Get a quote or advice
Tell us what you need and an engineer will come back to you.