eddyNCDT 3001 Inductive (eddy current)
eddyNCDT 3001: sensors and measurement devices by Micro-Epsilon for inductive (eddy current).
Download the datasheet (opens in a new tab) This series on the Micro-Epsilon site (opens in a new tab)
Shared technical specifications for the series
Properties every model in the series has. What differs is in the models table below.
Range across models
The span covered by the models of the series together — not the range of each model.
| Protection class (DIN EN 60529) | ip67 |
|---|---|
| Storage temperature | -20–80 °C |
| Upper cutoff frequency | 5000 Hz |
| Measuring range | 4 mm |
| Number of measurement channels | 1 |
| Accuracy | 28 µm |
| Linearity | 28 µm |
| Resolution | 4 µm |
| Minimum target diameter | 48 mm |
| ADC sampling rate | 75000 samples/s |
| Interfaces | ethernet |
| Supply voltage | 12–32 V |
| End of measuring range | 4.4 mm |
| Operating temperature | 0–70 °C |
| Working distance | 0.4–4.4 mm |
| Start of measuring range | 0.4 mm |
Models in the series
One column per model: what differs between the models of the series.
| Parameter | DT3001-U2-A-SA eli-m-7acbe4b0b2880ecfec960440 | DT3001-U2-M-SA eli-m-c3f77d541790f5db0953b136 | DT3001-U4-A-SA eli-m-518bb2e2ab8cac09cbc82dde | DT3001-U4-M-SA eli-m-a6b6a3645d8920b7599d9003 | DT3001-U6-A-SA eli-m-287f7301073caadd327955bc | DT3001-U6-M-SA eli-m-a763ae377e018cb048c6459c | DT3001-U8-A-SA eli-m-ef9929050bb505873db11ea2 | DT3001-U8-M-SA eli-m-df02187363e111fc0376b0ef |
|---|---|---|---|---|---|---|---|---|
| Protection class (DIN EN 60529) | ip67 | ip67 | ip67 | ip67 | ip67 | ip67 | ip67 | ip67 |
| Storage temperature | -20–80 °C | -20–80 °C | -20–80 °C | -20–80 °C | -20–70 °C | -20–70 °C | -20–70 °C | -20–70 °C |
| Upper cutoff frequency | 5000 Hz | 5000 Hz | 5000 Hz | 5000 Hz | 5000 Hz | 5000 Hz | 5000 Hz | 5000 Hz |
| Measuring range | 2 mm | 2 mm | 4 mm | 4 mm | 6 mm | 6 mm | 8 mm | 8 mm |
| Number of measurement channels | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 |
| Accuracy | 28 µm | 28 µm | 28 µm | 28 µm | 15 µm | 15 µm | 20 µm | 20 µm |
| Linearity | 28 µm | 28 µm | 28 µm | 28 µm | 15 µm | 15 µm | 20 µm | 20 µm |
| Resolution | 4 µm | 4 µm | 4 µm | 4 µm | 3 µm | 3 µm | 4 µm | 4 µm |
| Minimum target diameter | 48 mm | 48 mm | 48 mm | 48 mm | 72 mm | 72 mm | 72 mm | 72 mm |
| ADC sampling rate | 75000 samples/s | 75000 samples/s | 75000 samples/s | 75000 samples/s | 75000 samples/s | 75000 samples/s | 75000 samples/s | 75000 samples/s |
| Interfaces | ethernet | ethernet | ethercat | ethernet | ethernet | ethercat | ethercat | ethercat |
| Supply voltage | 12–32 V | 12–32 V | 12–32 V | 12–32 V | 12–32 V | 12–32 V | 12–32 V | 12–32 V |
| End of measuring range | 2.4 mm | 2.4 mm | 4.4 mm | 4.4 mm | 6.6 mm | 6.6 mm | 8.800000000000001 mm | 8.800000000000001 mm |
| Operating temperature | 0–70 °C | 0–70 °C | 0–70 °C | 0–70 °C | -20–70 °C | -20–70 °C | -20–70 °C | -20–70 °C |
| Working distance | 0.4–2.4 mm | 0.4–2.4 mm | 0.4–4.4 mm | 0.4–4.4 mm | 0.6–6.6 mm | 0.6–6.6 mm | 0.8–8.800000000000001 mm | 0.8–8.800000000000001 mm |
| Start of measuring range | 0.4 mm | 0.4 mm | 0.4 mm | 0.4 mm | 0.6 mm | 0.6 mm | 0.8 mm | 0.8 mm |
| source_calibrated_target_material | "Aluminum" | "Steel" | "Aluminum" | "Steel" | "Aluminum" | "Steel" | "Aluminum" | "Steel" |
| interface_specification | Analog 0-10V | Analog 0-10V | Digital I/O | Analog 0-10V | Digital I/O | Digital I/O | RS422 / RS485 | Analog 0-10V |
| quantity_specification | 0-2 mm model-level measuring interval | 0-2 mm model-level measuring interval | 0-4 mm model-level measuring interval | 0-4 mm model-level measuring interval | 0-6 mm model-level measuring interval | 0-6 mm model-level measuring interval | 0-8 mm model-level measuring interval | 0-8 mm model-level measuring interval |
| source_sampling_rate_basis | Integrated DT3001 electronics: 75 kSamples/s, 5 kHz bandwidth | Integrated DT3001 electronics: 75 kSamples/s, 5 kHz bandwidth | Integrated DT3001 electronics: 75 kSamples/s, 5 kHz bandwidth | Integrated DT3001 electronics: 75 kSamples/s, 5 kHz bandwidth | Integrated DT3001 electronics: 75 kSamples/s, 5 kHz bandwidth | Integrated DT3001 electronics: 75 kSamples/s, 5 kHz bandwidth | Integrated DT3001 electronics: 75 kSamples/s, 5 kHz bandwidth | Integrated DT3001 electronics: 75 kSamples/s, 5 kHz bandwidth |
| source_sensor_shielding | "unshielded" | "unshielded" | "unshielded" | "unshielded" | "unshielded" | "unshielded" | "unshielded" | "unshielded" |
| Status | Active | Active | Active | Active | Active | Active | Active | Active |
| Datasheet | PDF — DT3001-U2-A-SA (opens in a new tab) | PDF — DT3001-U2-M-SA (opens in a new tab) | PDF — DT3001-U4-A-SA (opens in a new tab) | PDF — DT3001-U4-M-SA (opens in a new tab) | PDF — DT3001-U6-A-SA (opens in a new tab) | PDF — DT3001-U6-M-SA (opens in a new tab) | PDF — DT3001-U8-A-SA (opens in a new tab) | PDF — DT3001-U8-M-SA (opens in a new tab) |
Compatible accessories
Cables
- PCx/5-M12 configurable component family eli-s-58d2ba937187973224f1636a Only for source configuration configuration-ef59e98edd09a24dcc4859f2: DT3001-U4-M-Cx; selected configuration must be matched before display.; 5 m standard; longer and drag-chain variants are optional. Not a sensor-controller extension.
Power supplies
- PS2020 (2420062) eli-m-75d559684cc51453ffe276de Only for source configuration configuration-ef59e98edd09a24dcc4859f2: DT3001-U4-M-Cx; selected configuration must be matched before display.; Calculate continuous and startup current for the complete chain. Being listed does not guarantee enough current for every configuration; never substitute for a mains-powered controller supply.
Complementary products
- IF1032/ETH eli-m-9f23885a1bd1bd049fa826c5 Only for source configuration configuration-ef59e98edd09a24dcc4859f2: DT3001-U4-M-Cx; selected configuration must be matched before display.; Conditional option for analog-output sensors: confirm that the selected voltage/current range and wiring match the IF1032 analog input; Ethernet is provided by the module, not native to the sensor.
The industries we serve
Frequently asked questions
Answers to the most common questions about our products and services
The measuring controller is integrated into the sensor housing. Power and an analog-output connection are still required; connector versions need the matching cable.
No. The catalogue distinguishes a 75 kHz analog-output update rate from a 5 kHz frequency response at −3 dB.
No. U8 has a 0.8 mm start offset, giving a 0.8–8.8 mm measurement interval and an 8 mm net span.
They identify target-material calibrations: A for aluminum and M for steel. Changing material requires a suitable calibration, not one universal metal characteristic.
No. Minimum target diameter is 48 mm for U2/U4 and 72 mm for U6/U8. Check material and distance as well.
Get a quote or advice
Tell us what you need and an engineer will come back to you.