EU05
From the eddyNCDT 3300 series
eddyNCDT 3300: sensors and measurement devices by Micro-Epsilon for inductive (eddy current).
- Number of measurement channels
- 1
Technical specification
Every engineering figure, laid out to scan quickly
| Measuring range | 0.4 mm |
|---|---|
| Start of measuring range | 0.05 mm |
| Linearity | 1 µm |
| Linearity (% FSO) | 0.2 % |
| Resolution | 0.05 µm |
| Resolution (% FSO) | 0.005 % |
| Minimum target diameter | 9 mm |
| Interfaces | ethercat |
| interface_specification | 4-20mA |
| Number of measurement channels | 1 |
| Storage temperature | -20–150 °C |
| Operating temperature | 0–150 °C |
| Protection class (DIN EN 60529) | ip64 |
| quantity_specification | 0-0.4 mm model-level measuring interval |
| source_sensor_mounting_specification | Mounting: Screw connection (table cell; model EU05) |
| interface_specification | Digital I/O |
| source_sampling_rate_basis | DT3301: 100 kHz controller bandwidth; a separate acquisition-rate specification is not published |
| interface_specification | RS422 / RS485 |
| Interfaces | ethernet |
| source_sampling_rate_basis | DT3300: 100 kHz controller bandwidth; a separate acquisition-rate specification is not published |
| interface_specification | Analog 0-10V |
| Resolution (% FSO) | 0.01 % |
| Resolution (% FSO) | 0.2 % |
| Contact | Non-contact |
The industries we serve
Get a quote or advice
Tell us what you need and an engineer will come back to you.