induSENSOR EDS LVDT
induSENSOR EDS: sensors and measurement devices by Micro-Epsilon for lvdt.
Download the datasheet (opens in a new tab) This series on the Micro-Epsilon site (opens in a new tab)
Shared technical specifications for the series
Properties every model in the series has. What differs is in the models table below.
Range across models
The span covered by the models of the series together — not the range of each model.
| Resolution | 38–315 µm |
|---|---|
| Accuracy | 230–1890 µm |
| ADC sampling rate | 500–600 samples/s |
Models in the series
One column per model: what differs between the models of the series.
| Parameter | EDS-100-F-SR-I eli-m-0100252373169b9d9e29ab22 | EDS-100-S-SA7-I eli-m-183c1460c72175089a2c80db | EDS-160-F-SR-I eli-m-88ae97a7b81977e9820c42de | EDS-160-S-SA7-I eli-m-5ff675d40f79ef1e3aa7ebdc | EDS-200-F-SR-I eli-m-abe9d5f33aa4b5cb49a2e514 | EDS-200-S-SA7-I eli-m-dfd7b996fc6c440ce9895f0b | EDS-250-F-SR-I eli-m-1f0efdf6730c17341a668967 | EDS-250-S-SA7-I eli-m-71a14dbde977574668be81e1 | EDS-300-F-SR-I eli-m-10fbbe563bb3b55e05f9c4f8 | EDS-300-S-SA7-I eli-m-c7786c59914f99615902f768 | EDS-400-F-SR-I eli-m-3be2519b2c207776dea2da60 | EDS-400-S-SA7-I eli-m-5c0b52f05000cc67c24f3a3f | EDS-500-S-SA7-I eli-m-11bf7762185f67eb2b3582a9 | EDS-630-F-SR-I eli-m-69f006abebc2245c43ae1339 | EDS-630-S-SA7-I eli-m-b0f58d0859e48c201ae73167 | EDS-75-S-SA7-I eli-m-461db4b891bc3cd0e4dcee43 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| interface_specification | 4-20mA | 4-20mA | 4-20mA | Analog 0-10V | Analog 0-10V | 4-20mA | 4-20mA | 4-20mA | 4-20mA | Analog 0-10V | 4-20mA | Analog 0-10V | 4-20mA | Analog 0-10V | Analog 0-10V | Analog 0-10V |
| Storage temperature | -40–100 °C | -40–100 °C | -40–100 °C | -40–100 °C | -40–100 °C | -40–100 °C | -40–100 °C | -40–100 °C | -40–100 °C | -40–100 °C | -40–100 °C | -40–100 °C | -40–100 °C | -40–100 °C | -40–100 °C | -40–100 °C |
| Operating temperature | -40–85 °C | -40–85 °C | -40–85 °C | -40–85 °C | -40–85 °C | -40–85 °C | -40–85 °C | -40–85 °C | -40–85 °C | -40–85 °C | -40–85 °C | -40–85 °C | -40–85 °C | -40–85 °C | -40–85 °C | -40–85 °C |
| source_linearity_basis | Official Micro-Epsilon induSENSOR EDS data: independent linearity for the retained range; resolution is captured separately. | Official Micro-Epsilon induSENSOR EDS data: independent linearity for the retained range; resolution is captured separately. | Official Micro-Epsilon induSENSOR EDS data: independent linearity for the retained range; resolution is captured separately. | Official Micro-Epsilon induSENSOR EDS data: independent linearity for the retained range; resolution is captured separately. | Official Micro-Epsilon induSENSOR EDS data: independent linearity for the retained range; resolution is captured separately. | Official Micro-Epsilon induSENSOR EDS data: independent linearity for the retained range; resolution is captured separately. | Official Micro-Epsilon induSENSOR EDS data: independent linearity for the retained range; resolution is captured separately. | Official Micro-Epsilon induSENSOR EDS data: independent linearity for the retained range; resolution is captured separately. | Official Micro-Epsilon induSENSOR EDS data: independent linearity for the retained range; resolution is captured separately. | Official Micro-Epsilon induSENSOR EDS data: independent linearity for the retained range; resolution is captured separately. | Official Micro-Epsilon induSENSOR EDS data: independent linearity for the retained range; resolution is captured separately. | Official Micro-Epsilon induSENSOR EDS data: independent linearity for the retained range; resolution is captured separately. | Official Micro-Epsilon induSENSOR EDS data: independent linearity for the retained range; resolution is captured separately. | Official Micro-Epsilon induSENSOR EDS data: independent linearity for the retained range; resolution is captured separately. | Official Micro-Epsilon induSENSOR EDS data: independent linearity for the retained range; resolution is captured separately. | Official Micro-Epsilon induSENSOR EDS data: independent linearity for the retained range; resolution is captured separately. |
| Resolution | 50 µm | 50 µm | 80 µm | 80 µm | 100 µm | 100 µm | 125 µm | 125 µm | 150 µm | 150 µm | 200 µm | 200 µm | 250 µm | 315 µm | 315 µm | 38 µm |
| source_sampling_rate_basis | Integrated EDS electronics controller | Integrated EDS electronics controller | Integrated EDS electronics controller | Integrated EDS electronics controller | Integrated EDS electronics controller | Integrated EDS electronics controller | Integrated EDS electronics controller | Integrated EDS electronics controller | Integrated EDS electronics controller | Integrated EDS electronics controller | Integrated EDS electronics controller | Integrated EDS electronics controller | Integrated EDS electronics controller | Integrated EDS electronics controller | Integrated EDS electronics controller | Integrated EDS electronics controller |
| Protection class (DIN EN 60529) | ip65 | ip67 | ip65 | ip67 | ip65 | ip67 | ip65 | ip67 | ip65 | ip67 | ip65 | ip67 | ip67 | ip65 | ip67 | ip67 |
| Upper cutoff frequency | 150 Hz | 150 Hz | 150 Hz | 150 Hz | 150 Hz | 150 Hz | 150 Hz | 150 Hz | 150 Hz | 150 Hz | 150 Hz | 150 Hz | 150 Hz | 150 Hz | 150 Hz | 150 Hz |
| Number of measurement channels | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 |
| quantity_specification | 0-100 mm model-level measuring interval | 0-100 mm model-level measuring interval | 0-160 mm model-level measuring interval | 0-160 mm model-level measuring interval | 0-200 mm model-level measuring interval | 0-200 mm model-level measuring interval | 0-250 mm model-level measuring interval | 0-250 mm model-level measuring interval | 0-300 mm model-level measuring interval | 0-300 mm model-level measuring interval | 0-400 mm model-level measuring interval | 0-400 mm model-level measuring interval | 0-500 mm model-level measuring interval | 0-630 mm model-level measuring interval | 0-630 mm model-level measuring interval | 0-75 mm model-level measuring interval |
| Supply voltage | 18–30 V | 18–30 V | 18–30 V | 18–30 V | 18–30 V | 18–30 V | 18–30 V | 18–30 V | 18–30 V | 18–30 V | 18–30 V | 18–30 V | 18–30 V | 18–30 V | 18–30 V | 18–30 V |
| Current consumption | 40 mA | 40 mA | 40 mA | 40 mA | 40 mA | 40 mA | 40 mA | 40 mA | 40 mA | 40 mA | 40 mA | 40 mA | 40 mA | 40 mA | 40 mA | 40 mA |
| Accuracy | 300 µm | 300 µm | 480 µm | 480 µm | 600 µm | 600 µm | 750 µm | 750 µm | 900 µm | 900 µm | 1200 µm | 1200 µm | 1500 µm | 1890 µm | 1890 µm | 230 µm |
| Contact | Contact | Contact | Contact | Contact | Contact | Contact | Contact | Contact | Contact | Contact | Contact | Contact | Contact | Contact | Contact | Contact |
| ADC sampling rate | 600 samples/s | 600 samples/s | 600 samples/s | 600 samples/s | 600 samples/s | 600 samples/s | 600 samples/s | 600 samples/s | 600 samples/s | 600 samples/s | 600 samples/s | 600 samples/s | 600 samples/s | 500 samples/s | 500 samples/s | 600 samples/s |
| Status | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active |
| Datasheet | PDF — EDS-100-F-SR-I (opens in a new tab) | PDF — EDS-100-S-SA7-I (opens in a new tab) | PDF — EDS-160-F-SR-I (opens in a new tab) | PDF — EDS-160-S-SA7-I (opens in a new tab) | PDF — EDS-200-F-SR-I (opens in a new tab) | PDF — EDS-200-S-SA7-I (opens in a new tab) | PDF — EDS-250-F-SR-I (opens in a new tab) | PDF — EDS-250-S-SA7-I (opens in a new tab) | PDF — EDS-300-F-SR-I (opens in a new tab) | PDF — EDS-300-S-SA7-I (opens in a new tab) | PDF — EDS-400-F-SR-I (opens in a new tab) | PDF — EDS-400-S-SA7-I (opens in a new tab) | PDF — EDS-500-S-SA7-I (opens in a new tab) | PDF — EDS-630-F-SR-I (opens in a new tab) | PDF — EDS-630-S-SA7-I (opens in a new tab) | PDF — EDS-75-S-SA7-I (opens in a new tab) |
The industries we serve
Frequently asked questions
Answers to the most common questions about our products and services
No. Controller and signal processing are integrated in the flange. Select supply, output cable and target tube for the EDS model.
An aluminum tube moves around the sensor rod without contact. The principle does not require a permanent magnet inside the cylinder.
No. S is specified as IP67 and F as IP65. Connector versions require the appropriate connected mating plug.
Standard output is 4–20 mA. S versions list a 1–5 V option using C703-5/U; do not automatically apply it to F versions.
No. The table distinguishes measuring span, rod length, tube length and offset. Match all dimensions to the cylinder integration.
Get a quote or advice
Tell us what you need and an engineer will come back to you.