Skip to content

Shared technical specifications for the series

Properties every model in the series has. What differs is in the models table below.

Range across models

The span covered by the models of the series together — not the range of each model.

Range across the models of mainSENSOR
Operating temperature -20–120 °C
Measuring range 12–55 mm
Upper cutoff frequency 1000–5000 Hz
Accuracy (% FSO) 3–9 %
Start of measuring range 1–5 mm
ADC sampling rate 1000–5000 samples/s
Linearity (% FSO) 5–9 %
Weight 0.0015–0.0045 kg
Current consumption 8.5–35 mA

Models in the series

One column per model: what differs between the models of the series.

Models of mainSENSOR compared by parameter
Parameter MDS-35-M12-CA-HT eli-m-3876ce9ef06229fa30478c29 MDS-35-M12-SA-HT eli-m-6580455984fb0c6c30652f57 MDS-40-D18-SA eli-m-5be0be81d1304095107cf260 MDS-40-LP-F eli-m-9a571adb9c141d5e374001f9 MDS-40-LP-SUS eli-m-15cad55657bd9c18f55d3de3 MDS-40-MK-SA8-I eli-m-3b16c0ca2b4458431d3f896a MDS-40-MK-SR0-F eli-m-d3d7ad25d8fc65f26a24733e MDS-40-MK-SR7-U10 eli-m-ec11b1632d88aa24dd8bcf92 MDS-40-MK-SR7-U45R eli-m-f422afee5d8004f24190725b MDS-45-M12-CA eli-m-68412b25fbea828889654b7e MDS-45-M12-SA eli-m-48885b2af59be6237fe9c449 MDS-45-M18-HP-SA eli-m-5b8d73f5278e563d9612188e MDS-45-M18-SA eli-m-777f01208f98f8a79566e1f1 MDS-45-M18-SA(01) eli-m-fb21fa5aebf639b48c8d9d0e MDS-45-M30-SA eli-m-e987b23b00b2f0352ea8b488
interface_specification Analog 0-10V Analog 0-10V Voltage 2 ±0.4 ... 9.6 ±0.4 V; current 4 ±0.8 ... 19.2 ±0.8 mA RS422 / RS485 Rectangular output; period duration 2.0 ... 3.3 ms RS422 / RS485 Digital I/O 4-20mA Digital I/O Digital I/O Analog 0-10V 4-20mA 4-20mA 4-20mA Voltage 2 ±0.2 ... 9.6 ±0.4 V; current 4 ±0.4 ... 19.2 ±0.8 mA
quantity_specification 0-35 mm model-level measuring interval 0-35 mm model-level measuring interval 0-40 mm model-level measuring interval 0-40 mm model-level measuring interval 0-40 mm model-level measuring interval 0-30 mm model-level measuring interval 0-30 mm model-level measuring interval 0-30 mm model-level measuring interval 0-30 mm model-level measuring interval 0-45 mm model-level measuring interval 0-45 mm model-level measuring interval 0-45 mm model-level measuring interval 0-45 mm model-level measuring interval 0-45 mm model-level measuring interval 0-45 mm model-level measuring interval
Operating temperature -20–120 °C -20–120 °C -20–80 °C -20–85 °C -20–85 °C -20–80 °C -20–80 °C -20–80 °C -20–80 °C -20–80 °C -20–80 °C -20–80 °C -20–80 °C -20–80 °C -20–80 °C
source_sampling_rate_basis Integrated electronics controller Integrated electronics controller Integrated electronics controller Integrated electronics controller Integrated electronics controller Integrated electronics controller Integrated electronics controller Integrated electronics controller Integrated electronics controller Integrated electronics controller Integrated electronics controller Integrated electronics controller Integrated electronics controller Integrated electronics controller Integrated electronics controller
Measuring range 12 mm 22 mm 30 mm 40 mm 40 mm 25 mm 50 mm 25 mm 30 mm 35 mm 52 mm 55 mm 33 mm 55 mm 33 mm
Interfaces ethernet ethercat ethernet ethernet ethercat ethernet ethercat ethernet ethercat ethercat ethercat ethernet ethercat ethernet ethercat
Upper cutoff frequency 5000 Hz 5000 Hz 1000 Hz Not specified Not specified 1000 Hz Not specified 1000 Hz 1000 Hz 3000 Hz 3000 Hz 3000 Hz 3000 Hz 3000 Hz 1000 Hz
Accuracy (% FSO) 5 % 5 % 5 % 9 % 6 % 5 % 5 % 5 % 5 % 3 % 3 % 3 % 3 % 3 % 3 %
Protection class (DIN EN 60529) ip67 ip67 ip67 Not specified Not specified ip67 ip20 ip67 ip20 ip67 ip67 ip67 ip67 ip67 ip67
source_delivered_magnet_code MB35HT MB35HT RL21 Not specified Not specified RL21 RL21 RL21 RL21 MB45 MB45 MB45 MB45 Not specified MB45
Start of measuring range 1 mm 1 mm 1.5 mm Not specified Not specified 1.5 mm 1.5 mm 1.5 mm 1.5 mm 5 mm 5 mm 2.25 mm 2.25 mm 2.25 mm 4 mm
Contact Non-contact Non-contact Non-contact Non-contact Non-contact Non-contact Non-contact Non-contact Non-contact Non-contact Non-contact Non-contact Non-contact Non-contact Non-contact
ADC sampling rate 5000 samples/s 5000 samples/s 1000 samples/s 1000 samples/s 1000 samples/s 1000 samples/s 1000 samples/s 1000 samples/s 1000 samples/s 5000 samples/s 5000 samples/s 3000 samples/s 3000 samples/s 3000 samples/s 1000 samples/s
Repeatability (% FSO) Not specified Not specified 0.05 % Not specified 0.05 % 0.05 % Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified
Linearity (% FSO) Not specified Not specified 5 % 9 % 6 % Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified
Resolution (% FSO) Not specified Not specified Not specified 0.05 % 0.05 % 0.05 % Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified
Weight Not specified Not specified Not specified 0.0015 kg 0.004500000000000001 kg Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified
Supply voltage Not specified Not specified Not specified 3.6–5.3 V 3.6–5.3 V Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified
Storage temperature Not specified Not specified Not specified -20–85 °C -20–85 °C Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified
source_integration_requirements Not specified Not specified Not specified EMC and ESD protection and voltage stabilization must be provided externally if required. EMC and ESD protection and voltage stabilization must be provided externally if required. Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified
Current consumption Not specified Not specified Not specified Not specified Not specified 35 mA 8.5 mA 13 mA 16 mA Not specified Not specified Not specified Not specified Not specified Not specified
Status Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active
Datasheet PDF — MDS-35-M12-CA-HT (opens in a new tab) PDF — MDS-35-M12-SA-HT (opens in a new tab) PDF — MDS-40-D18-SA (opens in a new tab) PDF — MDS-40-LP-F (opens in a new tab) PDF — MDS-40-LP-SUS (opens in a new tab) PDF — MDS-40-MK-SA8-I (opens in a new tab) PDF — MDS-40-MK-SR0-F (opens in a new tab) PDF — MDS-40-MK-SR7-U10 (opens in a new tab) PDF — MDS-40-MK-SR7-U45R (opens in a new tab) PDF — MDS-45-M12-CA (opens in a new tab) PDF — MDS-45-M12-SA (opens in a new tab) PDF — MDS-45-M18-HP-SA (opens in a new tab) PDF — MDS-45-M18-SA (opens in a new tab) PDF — MDS-45-M18-SA(01) (opens in a new tab) PDF — MDS-45-M30-SA (opens in a new tab)

The industries we serve

Frequently asked questions

Answers to the most common questions about our products and services

The selected magnet determines the range; the manufacturer describes 20–55 mm options using different specified magnets.

No. Its continuous linear distance signal supports displacement measurement rather than only presence detection.

Yes. It measures distance to a suitable target magnet. Match magnet to range and geometry rather than assuming all magnets provide identical performance.

The manufacturer describes measurement through non-ferromagnetic materials such as aluminium. This does not establish suitability through ferromagnetic steel.

No. It measures the magnet without contact. Install magnet and sensor so distance and motion remain within the selected configuration.

Didn't find the answer you were looking for?

Talk to an expert

More information

Get a quote or advice

Tell us what you need and an engineer will come back to you.

Request a quote for this product
What would you like to ask for?

Email or phone — one of them is enough

Email or phone — one of them is enough

0 of 500 words