optoNCDT 1750 Laser triangulation

optoNCDT 1750: sensors and measurement devices by Micro-Epsilon for laser triangulation.

Download the datasheet (opens in a new tab) This series on the Micro-Epsilon site (opens in a new tab)

Shared technical specifications for the series

Properties every model in the series has. What differs is in the models table below.

Range across models

The span covered by the models of the series together — not the range of each model.

Range across the models of optoNCDT 1750
Light spot diameter 0.08–0.32 mm
Repeatability 0.1–0.8 µm
Start of measuring range 24–53.5 mm
End of measuring range 26–73.5 mm
Measuring range 2–20 mm
Linearity 1.6–12 µm

Models in the series

One column per model: what differs between the models of the series.

Models of optoNCDT 1750 compared by parameter
Parameter ILD1750-10DR eli-m-327f6fd6d08f2a79ae47be4c ILD1750-20DR eli-m-879c466d7f517628278abea5 ILD1750-2DR eli-m-dd30b95f3b433016de6f2294
Light spot diameter 0.11 mm 0.32 mm 0.08 mm
Repeatability 0.4 µm 0.8 µm 0.1 µm
Start of measuring range 30.5 mm 53.5 mm 24 mm
Operating temperature 0–50 °C 0–50 °C 0–50 °C
Interfaces ethernet profinet ethernet
End of measuring range 40.5 mm 73.5 mm 26 mm
Protection class (DIN EN 60529) ip65 ip65 ip65
Measuring range 10 mm 20 mm 2 mm
Linearity 6 µm 12 µm 1.6 µm
Measuring rate 7500 Hz 7500 Hz 7500 Hz
interface_specification RS422 / RS485 RS422 / RS485 RS422 / RS485
Contact Non-contact Non-contact Non-contact
ADC sampling rate 7500 samples/s 7500 samples/s 7500 samples/s
Status Active Active Active
Datasheet PDF — ILD1750-10DR (opens in a new tab) PDF — ILD1750-20DR (opens in a new tab) PDF — ILD1750-2DR (opens in a new tab)

The industries we serve

Frequently asked questions

Answers to the most common questions about our products and services

Yes. The manual describes using the sensor button and LED indications to select rate and averaging. Follow its operating and saving sequence.

No. The manual lists selectable rates up to 7.5 kHz and separate averaging settings. State the operating settings when evaluating measurement performance.

It adjusts exposure and laser output to target reflectance during measurement, helping stabilize signals when reflection properties change.

No. BL denotes blue laser and DR direct-reflection geometry. Each has its own model columns, geometry and performance; select for the surface.

The catalogue footnote requires an interface module for the listed Industrial Ethernet connections. Match adapter to the model and required protocol.

Didn't find the answer you were looking for?

Talk to an expert

More information

Get a quote or advice

Tell us what you need and an engineer will come back to you.

Request a quote for this product
What would you like to ask for?

Email or phone — one of them is enough

Email or phone — one of them is enough

0 of 500 words