Technical specification for ILD2310-40
Measuring range 20 mm
Measuring window 175–215 mm
Working distance 175–215 mm
Linearity 12 µm
Linearity (% FSO) 0.03 %
Repeatability 0.5 µm
Resolution 2 µm
Measuring rate 49140 Hz
Interfaces ethercat
interface_specification RS422 / RS485
Operating temperature 0–50 °C
Protection class (DIN EN 60529) ip65
source_connection_plug 14-pin ODU plug
Cable length 0.25 m
quantity_specification Measuring range 40 mm; start/midpoint/end 175/195/215 mm. At 49.14 kHz the usable interval is 20 mm (195-215 mm absolute distance).
Accuracy (% FSO) 0.03 %
Minimum cable bend radius 30 mm
source_aluminum_housing Aluminum housing
source_measurement_reference_surface The specified data apply to white, diffuse reflecting surfaces (Micro-Epsilon reference ceramic for ILD sensors)
Interfaces profinet
Measuring rate 10000 Hz
Light spot diameter 0.23 mm
source_repeatability_basis Official repeatability 0.5 µm under datasheet reference conditions.
source_sampling_rate_basis Up to 49.14 kHz; the maximum-rate optical interval is 20 mm rather than the full 40 mm range.
interface_specification Analog 0-10V
Light spot diameter 0.21 mm
interface_specification Digital I/O
source_linearity_basis Official maximum linearity deviation ±12 µm, equivalent to ±0.03% FSO.
Interfaces ethernet
Measuring range 40 mm
interface_specification 4-20mA
Measuring window 195–215 mm
Contact Non-contact
Request a quote for this product

Compatible accessories

Cables

Complementary products

Accessories

  • SGH size M eli-m-6d7682eb71ffea3b7ea42245 Exact published sensor/housing fit. Housing rating is separate from the sensor rating; retain cooling requirements for HT.
  • SGHF size M eli-m-de67d3b1a80059a9db255727 Exact published sensor/housing fit. Housing rating is separate from the sensor rating; retain cooling requirements for HT.
  • SGHF-HT eli-m-eea3d522d2ea293e8452a9d0 Exact published sensor/housing fit. Housing rating is separate from the sensor rating; retain cooling requirements for HT.

The industries we serve

Get a quote or advice

Tell us what you need and an engineer will come back to you.

Request a quote for this product
What would you like to ask for?

Email or phone — one of them is enough

Email or phone — one of them is enough

0 of 500 words