Skip to content

optoNCDT Blue Laser Laser triangulation

optoNCDT Blue Laser: sensors and measurement devices by Micro-Epsilon for laser triangulation.

Download the datasheet (opens in a new tab) This series on the Micro-Epsilon site (opens in a new tab)

Shared technical specifications for the series

Properties every model in the series has. What differs is in the models table below.

Range across models

The span covered by the models of the series together — not the range of each model.

Range across the models of optoNCDT Blue Laser
rate_option 625–49140 Hz
Repeatability 0.8–45 µm
Start of measuring range 40–200 mm
Measuring range 2–750 mm
Measuring rate 7500–49140 Hz
Linearity 0.6–670 µm
Light spot diameter 0.045–1.5 mm
End of measuring range 60–950 mm
ADC sampling rate 7500–49140 samples/s
Measuring window 24–600 mm
Resolution 0.03–7.5 µm
Light spot width Y 0.045–0.4 mm
Light spot width X 0.02–0.032 mm

Models in the series

One column per model: what differs between the models of the series.

Models of optoNCDT Blue Laser compared by parameter
Parameter ILD1750-200BL eli-m-0658ab4966dcdf05ede32824 ILD1750-20BL eli-m-a77f5d7b56ef6774f1c1fac3 ILD1750-500BL eli-m-2ce8e901318e493539200986 ILD1750-750BL eli-m-dac44af361d0e5a560fc8f30 ILD2300-10BL eli-m-49c3110bab17ade6782765fa ILD2300-2BL eli-m-6e284d0ddee7dac1917dd314 ILD2300-5BL eli-m-7eddd90421f212878857682e ILD2310-50BL eli-m-985f5f642ae6eaa522c4c0cb
rate_option 5000 Hz 625 Hz 1250 Hz 2500 Hz 20000 Hz 5000 Hz 2500 Hz 49140 Hz
Repeatability 15 µm 0.8 µm 20 µm 45 µm Not specified Not specified Not specified Not specified
Protection class (DIN EN 60529) ip65 ip65 ip65 ip65 ip65 ip65 ip65 ip65
Start of measuring range 100 mm 40 mm 200 mm 200 mm Not specified Not specified Not specified Not specified
Measuring range 200 mm 20 mm 500 mm 750 mm 5 mm 2 mm 2 mm 25 mm
Measuring rate 7500 Hz 7500 Hz 7500 Hz 7500 Hz 20000 Hz 49140 Hz 49140 Hz 49140 Hz
Operating temperature 0–50 °C 0–50 °C 0–50 °C 0–50 °C 0–50 °C 0–50 °C 0–50 °C 0–50 °C
interface_specification Analog 0-10V Analog 0-10V RS422 / RS485 RS422 / RS485 Analog 0-10V RS422 / RS485 Analog 0-10V Analog 0-10V
Linearity 160 µm 12 µm 350 µm 670 µm 2 µm 0.6 µm 1.5 µm 40 µm
Light spot diameter 1.3 mm 0.045 mm 1.5 mm 1.5 mm Not specified Not specified Not specified Not specified
End of measuring range 300 mm 60 mm 700 mm 950 mm Not specified Not specified Not specified Not specified
Interfaces ethernet ethercat usb ethernet usb usb ethercat ethercat
Resolution (% FSO) 0.0015 % 0.0015 % 0.0015 % 0.0015 % 0.0015 % 0.0015 % 0.0015 % 0.0015 %
Storage temperature -20–70 °C -20–70 °C -20–70 °C -20–70 °C -20–70 °C -20–70 °C -20–70 °C -20–70 °C
Contact Non-contact Non-contact Non-contact Non-contact Non-contact Non-contact Non-contact Non-contact
ADC sampling rate 7500 samples/s 7500 samples/s 7500 samples/s 7500 samples/s 49140 samples/s 49140 samples/s 49140 samples/s 49140 samples/s
Measuring window Not specified Not specified Not specified Not specified 30–40 mm 24–26 mm 24–26 mm 550–600 mm
Resolution Not specified Not specified Not specified Not specified 0.15 µm 0.03 µm 0.08 µm 7.5 µm
Light spot width Y Not specified Not specified Not specified Not specified 0.045 mm 0.1 mm 0.4 mm Not specified
Light spot width X Not specified Not specified Not specified Not specified 0.032 mm 0.02 mm 0.02 mm Not specified
Status Active Active Active Active Active Active Active Active
Datasheet PDF — ILD1750-200BL (opens in a new tab) PDF — ILD1750-20BL (opens in a new tab) PDF — ILD1750-500BL (opens in a new tab) PDF — ILD1750-750BL (opens in a new tab) PDF — ILD2300-10BL (opens in a new tab) PDF — ILD2300-2BL (opens in a new tab) PDF — ILD2300-5BL (opens in a new tab) PDF — ILD2310-50BL (opens in a new tab)

The industries we serve

Frequently asked questions

Answers to the most common questions about our products and services

Micro-Epsilon’s blue-laser technology reduces penetration into the target surface and provides a sharper image on the detector. This helps on challenging materials, depending on the series and application.

No. It is a technology used by several optoNCDT families. Select range, measuring rate and linearity for the specific model rather than by laser colour alone.

No. For example, 1750BL and 2300BL belong to different platforms. Use the model table for rate and available measurement window.

No. Spot size varies with model and target position. Match the measured feature and retain both dimensions when the spot is not circular.

The table provides bracketed range values for this rate. Some models use a reduced window, so check span and rate together.

Didn't find the answer you were looking for?

Talk to an expert

More information

Get a quote or advice

Tell us what you need and an engineer will come back to you.

Request a quote for this product
What would you like to ask for?

Email or phone — one of them is enough

Email or phone — one of them is enough

0 of 500 words