wireSENSOR MT
wireSENSOR MT draw-wire sensors; range and output are selected per model.
Download the datasheet (opens in a new tab) This series on the Micro-Epsilon site (opens in a new tab)
Shared technical specifications for the series
Properties every model in the series has. What differs is in the models table below.
Range across models
The span covered by the models of the series together — not the range of each model.
| Measuring range | 40–130 mm |
|---|---|
| Linearity (% FSO) | 0.4–2 % |
| Linearity | 320–800 µm |
Models in the series
One column per model: what differs between the models of the series.
| Parameter | WDS-130-MT56-P eli-m-a2620316b7d99466480d85ac | WDS-40-MT19-P eli-m-3184fabb5b92cb22df61db3e | WDS-80-MT33-P eli-m-30fc6a5cda2b5c5968d0cd25 |
|---|---|---|---|
| Measuring range | 130 mm | 40 mm | 80 mm |
| Selected electrical output | potentiometer | potentiometer | potentiometer |
| Selected configuration options | range=130 mm; suffix=P; output=Potentiometer / resistance divider | range=40 mm; suffix=P; output=Potentiometer / resistance divider | range=80 mm; suffix=P; output=Potentiometer / resistance divider |
| Selected connection | Stranded wires, approximately 6 cm | Stranded wires, approximately 6 cm | Stranded wires, approximately 6 cm |
| Protection class (DIN EN 60529) | IP50 | IP50 | IP50 |
| Linearity (% FSO) | 0.4 % | Page 47 footnote: typically 1%, maximum 2% FSO; hard comparison uses the maximum 2%. | 0.4 % |
| Linearity | 520 µm | Page 47 footnote: typically 1%, maximum 2% FSO; hard comparison uses the maximum 2%. | 320 µm |
| Mechanical details from model-specific source cells | Resolution: source gives a qualitative potentiometer limit; no numeric zero assigned. | Resolution: source gives a qualitative potentiometer limit; no numeric zero assigned. | Resolution: source gives a qualitative potentiometer limit; no numeric zero assigned. |
| Contact | Contact | Contact | Contact |
| Status | Active | Active | Active |
| Datasheet | PDF — WDS-130-MT56-P (opens in a new tab) | PDF — WDS-40-MT19-P (opens in a new tab) | PDF — WDS-80-MT33-P (opens in a new tab) |
The industries we serve
Frequently asked questions
Answers to the most common questions about our products and services
The table includes WDS-40-MT19-P, WDS-80-MT33-P and WDS-130-MT56-P, with 40, 80 and 130 mm ranges. All use a potentiometer output, but their dimensions and mechanical specifications differ.
No. The listed maximum wire acceleration is approximately 60g for the 40 and 80 mm models and approximately 15g for the 130 mm model. The higher value is not a family-wide rating.
MT specifies IP50. Do not inherit IP65 or IP67 from other draw-wire families. Its operating temperature range is −40 to +85°C.
No. WDS-40-MT19 specifies typical ±1% and maximum ±2% FSO. The 80 and 130 mm models specify ±0.4% FSO. Preserve typical-versus-maximum qualification.
Electrical connection uses approximately 6 cm flying leads, with a 4.5 mm wire eyelet. Housing mounting-hole diameters vary by model, so use the corresponding drawing.
Get a quote or advice
Tell us what you need and an engineer will come back to you.