surfaceCONTROL 3D 2500 Measurement & 3D systems
surfaceCONTROL 3D 2500: sensors and measurement devices by Micro-Epsilon for measurement & 3d systems.
Download the datasheet (opens in a new tab) This series on the Micro-Epsilon site (opens in a new tab)
Shared technical specifications for the series
Properties every model in the series has. What differs is in the models table below.
Range across models
The span covered by the models of the series together — not the range of each model.
| X measuring range | 300–575 mm |
|---|---|
| Working distance | 475–1250 mm |
| Repeatability | 0.5–3 µm |
| Y resolution | 125–250 µm |
| Resolution | 1.2–8.5 µm |
| Z measuring range | 150–300 mm |
| X resolution | 125–250 µm |
| Y measuring range | 220–435 mm |
Models in the series
One column per model: what differs between the models of the series.
| Parameter | SC2500-300 eli-m-5541e208cc5d898822a149c9 | SC2500-400 eli-m-a30f41de83bcca13f754e394 | SC2500-575 eli-m-56f825fcdb43ef2ad03e8f8f | SC2510-300 eli-m-90fcac0c2cee4899c83c247b | SC2510-400 eli-m-c3f5b7f827b6929500250bfe | SC2510-575 eli-m-ea7f3375d76d863396cbdef4 |
|---|---|---|---|---|---|---|
| Protection class (DIN EN 60529) | ip40 | ip40 | ip40 | ip40 | ip40 | ip40 |
| X measuring range | 300 mm | 400 mm | 575 mm | 300 mm | 400 mm | 575 mm |
| Working distance | 475–625 mm | 660–860 mm | 950–1250 mm | 475–625 mm | 660–860 mm | 950–1250 mm |
| ADC sampling rate | 2 samples/s | 2 samples/s | 2 samples/s | 2 samples/s | 2 samples/s | 2 samples/s |
| Interfaces | profinet | profinet | ethercat | profinet | ethercat | ethercat |
| Operating temperature | 5–40 °C | 5–40 °C | 5–40 °C | 5–40 °C | 5–40 °C | 5–40 °C |
| Repeatability | 0.5 µm | 1.2 µm | 3 µm | 0.5 µm | 1.2 µm | 3 µm |
| Y resolution | 125 µm | 150 µm | 250 µm | 125 µm | 150 µm | 250 µm |
| Resolution | 1.2 µm | 3.4 µm | 8.5 µm | 1.2 µm | 3.4 µm | 8.5 µm |
| Z measuring range | 150 mm | 200 mm | 300 mm | 150 mm | 200 mm | 300 mm |
| quantity_specification | Start 260 x 190 mm at 475 mm; center 300 x 220 mm at 550 mm; end 340 x 250 mm at 625 mm. | Start 350 x 260 mm at 660 mm; center 400 x 300 mm at 760 mm; end 450 x 340 mm at 860 mm. | Start 500 x 375 mm at 950 mm; center 575 x 435 mm at 1100 mm; end 650 x 495 mm at 1250 mm. | Start 260 x 190 mm at 475 mm; center 300 x 220 mm at 550 mm; end 340 x 250 mm at 625 mm. | Start 350 x 260 mm at 660 mm; center 400 x 300 mm at 760 mm; end 450 x 340 mm at 860 mm. | Start 500 x 375 mm at 950 mm; center 575 x 435 mm at 1100 mm; end 650 x 495 mm at 1250 mm. |
| X resolution | 125 µm | 150 µm | 250 µm | 125 µm | 150 µm | 250 µm |
| interface_specification | Digital I/O | Digital I/O | Digital I/O | Digital I/O | Digital I/O | Digital I/O |
| Y measuring range | 220 mm | 300 mm | 435 mm | 220 mm | 300 mm | 435 mm |
| Status | Active | Active | Active | Active | Active | Active |
| Datasheet | PDF — SC2500-300 (opens in a new tab) | PDF — SC2500-400 (opens in a new tab) | PDF — SC2500-575 (opens in a new tab) | PDF — SC2510-300 (opens in a new tab) | PDF — SC2510-400 (opens in a new tab) | PDF — SC2510-575 (opens in a new tab) |
The industries we serve
Frequently asked questions
Answers to the most common questions about our products and services
Yes. Images go to the SC2500 controller for 3D calculation. This differs from series with processing integrated into the head.
No. It is the end-of-range field of the largest tabulated model. Each model has separate fields at working-range start, middle and end.
No. The table specifies <0.5, <1.2 and <3.0 µm by model under stated surface, filtering and temperature conditions.
No. The footnote excludes processing and evaluation from pattern-sequence acquisition time. A full cycle also includes these and communication.
Match head, controller, connections and evaluation software. The tabulated head and controller are IP40; do not transfer another series’ IP67 rating.
Get a quote or advice
Tell us what you need and an engineer will come back to you.