thicknessCONTROL STG 8101-CLLT-75/2200
From the thicknessCONTROL STG 8101 series
thicknessCONTROL STG 8101: system by Micro-Epsilon.
- System accuracy
- 3 µm
Technical specification
Every engineering figure, laid out to scan quickly
| System accuracy | 3 µm |
|---|---|
| Resolution | 1 µm |
| Maximum material width | 2200 mm |
| Interfaces | profinet |
| interface_specification | Analog 0-10V |
| Operating temperature | 5–60 °C |
| quantity_specification | 75 mm thickness measuring range; 2200 mm named measuring width; article 4350006.520. |
| source_repeatability_basis | Official source value, normally stated at 2 sigma where identified in the family table. |
| Repeatability | 0.5 µm |
| Interfaces | ethernet |
| Interfaces | ethercat |
| interface_specification | Digital I/O |