Skip to content

thicknessCONTROL STG 8102-LLT-50/500

From the thicknessCONTROL STG 8102 series

thicknessCONTROL STG 8102: system by Micro-Epsilon.

System accuracy
3 µm
Download the datasheet (opens in a new tab) This series on the Micro-Epsilon site (opens in a new tab)

Technical specification

Every engineering figure, laid out to scan quickly

Technical specification for thicknessCONTROL STG 8102-LLT-50/500
System accuracy 3 µm
Resolution 1 µm
Maximum material width 500 mm
Interfaces ethernet
interface_specification Digital I/O
Operating temperature 5–45 °C
quantity_specification 50 mm thickness measuring range; 500 mm named measuring width; article 4350127.234.
ADC sampling rate 70000 samples/s
interface_specification Analog 0-10V
Interfaces ethercat
source_repeatability_basis Official source value, normally stated at 2 sigma where identified in the family table.
source_sampling_rate_basis Official maximum measurement or output rate: 70,000 Hz.
Repeatability 1 µm
Interfaces profinet
Request a quote for this product

Compatible accessories

Complementary products

The industries we serve

Get a quote or advice

Tell us what you need and an engineer will come back to you.

Request a quote for this product
What would you like to ask for?

Email or phone — one of them is enough

Email or phone — one of them is enough

0 of 500 words