C10-500kN
From the C10 series
C10: sensors and measurement devices by HBK for force.
- Force range
- 0–500000 N
Technical specification
Every engineering figure, laid out to scan quickly
| Force range | 0–500000 N |
|---|---|
| Accuracy (% FSO) | 0.02 % |
| Interfaces | profinet |
| interface_specification | Digital I/O |
| Operating temperature | -10–60 °C |
| Protection class (DIN EN 60529) | ip68 |
| quantity_specification | 500 kN rated capacity = 500 kN (50.9858 t mass equivalent at standard gravity); compression |
| ADC sampling rate | 450 samples/s |
| Ordering options and constraints | K-C10 — capacity: 2.5 kN, 5 kN, 10 kN, 25 kN, 50 kN, 100 kN, 250 kN, 500 kN, 1 MN; bridge: SB, DB; rated_output: N, J; calibration: 50%, 100%; teds: Not selected, T; mechanical_design: W adapter, N flange; plug_protection: P, U; electrical_connection: B, G, K (6 m), V (15 m), 00A4 (VAIO); force_application: O, L; cable_plug: Y, F, Q, N, P, M, X; integrated_amplifier: N, VAIO; constraints: [{"when": {"teds": "T"}, "deny": {"integrated_amplifier": ["VAIO"]}, "reason": "TEDS and the integrated VAIO amplifier are mutually exclusive in the official configuration."}, {"when": {"integrated_amplifier": "VAIO"}, "allow": {"electrical_connection": "00A4 (VAIO)"}, "reason": "The VAIO connection is reserved for the integrated-amplifier option."}] |
| source_sampling_rate_basis | MX840B maximum per-channel sample rate; sensor mechanics and filter settings can reduce usable bandwidth |
| Interfaces | ethernet |
| Protection class (DIN EN 60529) | ip67 |
| Protection class (DIN EN 60529) | ip64 |
| Interfaces | io_link |
| source_sampling_rate_basis | ClipX fixed internal sampling rate; verify the configured filter and usable output bandwidth |
| Interfaces | ethercat |
| Operating temperature | -30–85 °C |
| ADC sampling rate | 19200 samples/s |
| ADC sampling rate | 1111 samples/s |
| source_sampling_rate_basis | 0.9 ms minimum IO-Link process-data cycle; the sensor electronics sample internally at 40 kHz |
| interface_specification | RS422 / RS485 |
| interface_specification | Analog 0-10V |
| source_sampling_rate_basis | DMP41 selectable result rate, intended for reference and calibration measurements |
| ADC sampling rate | 40000 samples/s |
Compatible accessories
Cables
- K-CAB-F-B eli-m-77598bb679b1cefd06e0eb15
- K-CAB-F-G eli-m-cb053e0dbafcb9f5c97d35d2
- K-CAB-F-L eli-m-da3a2435c758af1a6a732a76
- 1-KAB157-3 eli-m-a68247a3773360ad7d0177e8
- 1-KAB158-3 eli-m-9dd63f28a1bb0c811ab235e7
- 1-CON/BS1 eli-m-fa3e0808051d0b0eb0fd786d
- 1-CON/BS2 eli-m-d369711675c68ed790d49233
- 3-3312.0354 eli-m-c1060f6ba73154ebaa44d5ef
Mounting
- 1-EDO3/500KN eli-m-b21a68a1e991954793fc8431