C10 Force
C10: sensors and measurement devices by HBK for force.
This series on the HBK site (opens in a new tab)
Shared technical specifications for the series
Properties every model in the series has. What differs is in the models table below.
| Ordering options and constraints | K-C10 — capacity: 2.5 kN, 5 kN, 10 kN, 25 kN, 50 kN, 100 kN, 250 kN, 500 kN, 1 MN; bridge: SB, DB; rated_output: N, J; calibration: 50%, 100%; teds: Not selected, T; mechanical_design: W adapter, N flange; plug_protection: P, U; electrical_connection: B, G, K (6 m), V (15 m), 00A4 (VAIO); force_application: O, L; cable_plug: Y, F, Q, N, P, M, X; integrated_amplifier: N, VAIO; constraints: [{"when": {"teds": "T"}, "deny": {"integrated_amplifier": ["VAIO"]}, "reason": "TEDS and the integrated VAIO amplifier are mutually exclusive in the official configuration."}, {"when": {"integrated_amplifier": "VAIO"}, "allow": {"electrical_connection": "00A4 (VAIO)"}, "reason": "The VAIO connection is reserved for the integrated-amplifier option."}] |
|---|
Range across models
The span covered by the models of the series together — not the range of each model.
| Operating temperature | -30–85 °C |
|---|---|
| Protection class (DIN EN 60529) | ip64 |
| Interfaces | io_link |
| Force range | 0–50000 N |
| ADC sampling rate | 450–40000 samples/s |
| Nominal force capacity | 2500–1000000 N |
Models in the series
One column per model: what differs between the models of the series.
| Parameter | 1-C10/100KN eli-m-88426b4535d2bdcbc60d6b8e | 1-C10/10KN eli-m-40d2e0365f94a8d3c7893960 | 1-C10/1MN eli-m-f2aa335dd14e4de56e82b28c | 1-C10/2.5KN eli-m-0162f147db2ff6793b6b040b | 1-C10/250KN eli-m-eca7a551a88ad46e4f946b7f | 1-C10/25KN eli-m-1f45cab53ea2c9268da07811 | 1-C10/500KN eli-m-89b5bd397bcbdce8cf87164e | 1-C10/50KN eli-m-0ba9d35d13f2c5a5627135cd | 1-C10/5KN eli-m-c16352b3a23e4927ad9ba585 | C10-1000kN eli-m-67c322875be0354b87ad4f67 | C10-100kN eli-m-972b22087b6ceb04d6ff1a2d | C10-10kN eli-m-243f3556b8d214c80a769fb7 | C10-250kN eli-m-89de05569f076e353c2163f8 | C10-25kN eli-m-25dd77490699db624bd63c51 | C10-2p5kN eli-m-0e5d3618dad8f9051ecda0b5 | C10-500kN eli-m-3ff3daa803cf6643454fd423 | C10-50kN eli-m-9ad2f6cbd625ec0a60324911 | C10-5kN eli-m-460a2991b3aaa74893dfd345 | K-C10 · 1 MN eli-m-09c6e5b1f85714630bfab2f0 | K-C10 · 10 kN eli-m-8d2215d06237cc4feae88b18 | K-C10 · 100 kN eli-m-4a2d3c1588f6496e431b02ef | K-C10 · 2.5 kN eli-m-36ba9af88400cd9523e4de33 | K-C10 · 25 kN eli-m-d8df5db738e7cc3214858cba | K-C10 · 250 kN eli-m-87b43e574a812b571bf7460e | K-C10 · 5 kN eli-m-784b701d265e7e7d13296234 | K-C10 · 50 kN eli-m-4ba9f6f512768d1b3ab029f9 | K-C10 · 500 kN eli-m-37d8f0d23d32a265af7630cf |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Operating temperature | -10–60 °C | -30–85 °C | -10–60 °C | -10–60 °C | -30–85 °C | -10–60 °C | -10–60 °C | -30–85 °C | -30–85 °C | -10–60 °C | -10–60 °C | -10–60 °C | -10–60 °C | -10–60 °C | -30–85 °C | -10–60 °C | -10–60 °C | -10–60 °C | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified |
| Protection class (DIN EN 60529) | ip64 | ip67 | ip64 | ip68 | ip67 | ip64 | ip64 | ip67 | ip67 | ip64 | ip68 | ip64 | ip64 | ip67 | ip68 | ip68 | ip67 | ip68 | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified |
| Interfaces | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | ethernet | ethernet | ethernet | ethernet | ethernet | ethernet | profinet | io_link | io_link | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified |
| Force range | 0–100000 N | 0–10000 N | 0–1000000 N | 0–2500 N | 0–250000 N | 0–25000 N | 0–500000 N | 0–50000 N | 0–5000 N | 0–1000000 N | 0–100000 N | 0–10000 N | 0–250000 N | 0–25000 N | 0–2500 N | 0–500000 N | 0–50000 N | 0–5000 N | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified |
| source_pressure_output | mV/V (passive strain gauge) | mV/V (passive strain gauge) | mV/V (passive strain gauge) | mV/V (passive strain gauge) | mV/V (passive strain gauge) | mV/V (passive strain gauge) | mV/V (passive strain gauge) | mV/V (passive strain gauge) | mV/V (passive strain gauge) | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified |
| source_sampling_rate_limited_by_readout | True | True | True | True | True | True | True | True | True | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified |
| interface_specification | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown | Analog 0-10V | Analog 0-10V | Analog 0-10V | Digital I/O | Analog 0-10V | Analog 0-10V | Digital I/O | RS422 / RS485 | Analog 0-10V | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified |
| source_repeatability_basis | Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. | Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. | Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. | Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. | Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. | Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. | Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. | Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. | Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified |
| quantity_specification | Maximum capacity (nominal load): 22.5 klbf; Output signal: mV/V (passive strain gauge); Height (without accessories): 1.87 in; Diameter (without cable or plug): 6.059043 in | Maximum capacity (nominal load): 2.25 klbf; Output signal: mV/V (passive strain gauge); Height (without accessories): 1.41 in; Diameter (without cable or plug): 4.125976 in | Maximum capacity (nominal load): 225 klbf; Output signal: mV/V (passive strain gauge); Height (without accessories): 3.33 in; Diameter (without cable or plug): 10.98423 in | Maximum capacity (nominal load): 562 lbf; Output signal: mV/V (passive strain gauge); Height (without accessories): 1.41 in; Diameter (without cable or plug): 4.125976 in | Maximum capacity (nominal load): 56.2 klbf; Output signal: mV/V (passive strain gauge); Height (without accessories): 1.87 in; Diameter (without cable or plug): 6.059043 in | Maximum capacity (nominal load): 5.62 klbf; Output signal: mV/V (passive strain gauge); Height (without accessories): 1.41 in; Diameter (without cable or plug): 4.125976 in | Maximum capacity (nominal load): 112 klbf; Output signal: mV/V (passive strain gauge); Height (without accessories): 2.57 in; Diameter (without cable or plug): 7.999984 in | Maximum capacity (nominal load): 11.24 klbf; Output signal: mV/V (passive strain gauge); Height (without accessories): 1.41 in; Diameter (without cable or plug): 4.125976 in | Maximum capacity (nominal load): 1.124 klbf; Output signal: mV/V (passive strain gauge); Height (without accessories): 1.41 in; Diameter (without cable or plug): 4.125976 in | 1000 kN rated capacity = 1,000 kN (101.9716 t mass equivalent at standard gravity); compression | 100 kN rated capacity = 100 kN (10.1972 t mass equivalent at standard gravity); compression | 10 kN rated capacity = 10 kN (1.0197 t mass equivalent at standard gravity); compression | 250 kN rated capacity = 250 kN (25.4929 t mass equivalent at standard gravity); compression | 25 kN rated capacity = 25 kN (2.5493 t mass equivalent at standard gravity); compression | 2.5 kN rated capacity = 2.5 kN (254.9291 kg mass equivalent at standard gravity); compression | 500 kN rated capacity = 500 kN (50.9858 t mass equivalent at standard gravity); compression | 50 kN rated capacity = 50 kN (5.0986 t mass equivalent at standard gravity); compression | 5 kN rated capacity = 5 kN (509.8581 kg mass equivalent at standard gravity); compression | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified |
| source_sampling_rate_basis | The selected HBK conditioner, filter and DAQ determine the digital sample rate. | The selected HBK conditioner, filter and DAQ determine the digital sample rate. | The selected HBK conditioner, filter and DAQ determine the digital sample rate. | The selected HBK conditioner, filter and DAQ determine the digital sample rate. | The selected HBK conditioner, filter and DAQ determine the digital sample rate. | The selected HBK conditioner, filter and DAQ determine the digital sample rate. | The selected HBK conditioner, filter and DAQ determine the digital sample rate. | The selected HBK conditioner, filter and DAQ determine the digital sample rate. | The selected HBK conditioner, filter and DAQ determine the digital sample rate. | MX840B maximum per-channel sample rate; sensor mechanics and filter settings can reduce usable bandwidth | ClipX fixed internal sampling rate; verify the configured filter and usable output bandwidth | DMP41 selectable result rate, intended for reference and calibration measurements | 0.9 ms minimum IO-Link process-data cycle; the sensor electronics sample internally at 40 kHz | 0.9 ms minimum IO-Link process-data cycle; the sensor electronics sample internally at 40 kHz | MX840B maximum per-channel sample rate; sensor mechanics and filter settings can reduce usable bandwidth | MX840B maximum per-channel sample rate; sensor mechanics and filter settings can reduce usable bandwidth | ClipX fixed internal sampling rate; verify the configured filter and usable output bandwidth | DMP41 selectable result rate, intended for reference and calibration measurements | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified |
| source_linearity_basis | No single accuracy class is inferred when it is not shown for the exact ordering code. | No single accuracy class is inferred when it is not shown for the exact ordering code. | No single accuracy class is inferred when it is not shown for the exact ordering code. | No single accuracy class is inferred when it is not shown for the exact ordering code. | No single accuracy class is inferred when it is not shown for the exact ordering code. | No single accuracy class is inferred when it is not shown for the exact ordering code. | No single accuracy class is inferred when it is not shown for the exact ordering code. | No single accuracy class is inferred when it is not shown for the exact ordering code. | No single accuracy class is inferred when it is not shown for the exact ordering code. | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified |
| Accuracy (% FSO) | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | 0.02 % | 0.02 % | 0.02 % | 0.02 % | 0.02 % | 0.02 % | 0.02 % | 0.02 % | 0.02 % | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified |
| ADC sampling rate | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | 40000 samples/s | 450 samples/s | 19200 samples/s | 1111 samples/s | 1111 samples/s | 40000 samples/s | 450 samples/s | 1111 samples/s | 40000 samples/s | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified |
| Selected configuration options | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | 1 MN nominal force capacity | 10 kN nominal force capacity | 100 kN nominal force capacity | 2.5 kN nominal force capacity | 25 kN nominal force capacity | 250 kN nominal force capacity | 5 kN nominal force capacity | 50 kN nominal force capacity | 500 kN nominal force capacity |
| Nominal force capacity | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | 1000000 N | 10000 N | 100000 N | 2500 N | 25000 N | 250000 N | 5000 N | 50000 N | 500000 N |
| Status | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active |
| Datasheet | PDF — K-C10 · 1 MN (opens in a new tab) | PDF — K-C10 · 10 kN (opens in a new tab) | PDF — K-C10 · 100 kN (opens in a new tab) | PDF — K-C10 · 2.5 kN (opens in a new tab) | PDF — K-C10 · 25 kN (opens in a new tab) | PDF — K-C10 · 250 kN (opens in a new tab) | PDF — K-C10 · 5 kN (opens in a new tab) | PDF — K-C10 · 50 kN (opens in a new tab) | PDF — K-C10 · 500 kN (opens in a new tab) |
Compatible accessories
Cables
- K-CAB-F-B eli-m-77598bb679b1cefd06e0eb15 Only for source configuration configuration-1c8a51fe4b0759651da3bc38: K-C10 · 1 MN configuration; selected configuration must be matched before display.; Only for the listed passive SG sensor socket; fixed-cable K/V and VAIO/4-pin IO-Link are excluded. Select the amplifier end and validate carrier-frequency precision, EMC and calibration with the cable length.; 0131: static/dynamic bend radius 22/50 mm, -50…80 °C, 280 Ω/km; high-precision use may require low carrier frequency and stable temperature. 0157: 37/75 mm, -50…85 °C, 78 Ω/km. 139B: 75 mm static, no drag chain; -30…70 °C stationary / -5…50 °C moving; incompatible with P/M ends.; IP protection depends on the actual sensor socket, seal and connector locking; a generic connector IP rating is not the assembled sensor IP rating.
- K-CAB-F-G eli-m-cb053e0dbafcb9f5c97d35d2 Only for source configuration configuration-1c8a51fe4b0759651da3bc38: K-C10 · 1 MN configuration; selected configuration must be matched before display.; Only for the listed passive SG sensor socket; fixed-cable K/V and VAIO/4-pin IO-Link are excluded. Select the amplifier end and validate carrier-frequency precision, EMC and calibration with the cable length.; 0131: static/dynamic bend radius 22/50 mm, -50…80 °C, 280 Ω/km; high-precision use may require low carrier frequency and stable temperature. 0157: 37/75 mm, -50…85 °C, 78 Ω/km. 139B: 75 mm static, no drag chain; -30…70 °C stationary / -5…50 °C moving; incompatible with P/M ends.; IP protection depends on the actual sensor socket, seal and connector locking; a generic connector IP rating is not the assembled sensor IP rating.
- K-CAB-F-L eli-m-da3a2435c758af1a6a732a76 Only for source configuration configuration-1c8a51fe4b0759651da3bc38: K-C10 · 1 MN configuration; selected configuration must be matched before display.; Only for the listed passive SG sensor socket; fixed-cable K/V and VAIO/4-pin IO-Link are excluded. Select the amplifier end and validate carrier-frequency precision, EMC and calibration with the cable length.; 0131: static/dynamic bend radius 22/50 mm, -50…80 °C, 280 Ω/km; high-precision use may require low carrier frequency and stable temperature. 0157: 37/75 mm, -50…85 °C, 78 Ω/km. 139B: 75 mm static, no drag chain; -30…70 °C stationary / -5…50 °C moving; incompatible with P/M ends.; IP protection depends on the actual sensor socket, seal and connector locking; a generic connector IP rating is not the assembled sensor IP rating.
- 1-KAB157-3 eli-m-a68247a3773360ad7d0177e8 Only for source configuration configuration-1c8a51fe4b0759651da3bc38: K-C10 · 1 MN configuration; selected configuration must be matched before display.; The threaded cable is rated differently in U10M and C10 documents; do not assign a universal IP class. Check socket, locked connector and end wiring.
- 1-KAB158-3 eli-m-9dd63f28a1bb0c811ab235e7 Only for source configuration configuration-1c8a51fe4b0759651da3bc38: K-C10 · 1 MN configuration; selected configuration must be matched before display.; The threaded cable is rated differently in U10M and C10 documents; do not assign a universal IP class. Check socket, locked connector and end wiring.
- 1-CON/BS1 eli-m-fa3e0808051d0b0eb0fd786d Only for source configuration configuration-1c8a51fe4b0759651da3bc38: K-C10 · 1 MN configuration; selected configuration must be matched before display.; BS1: cable Ø4–6.5 mm; BS2: Ø≥6.5 mm. Match bayonet/threaded sensor connection, sealing and wiring.
- 1-CON/BS2 eli-m-d369711675c68ed790d49233 Only for source configuration configuration-1c8a51fe4b0759651da3bc38: K-C10 · 1 MN configuration; selected configuration must be matched before display.; BS1: cable Ø4–6.5 mm; BS2: Ø≥6.5 mm. Match bayonet/threaded sensor connection, sealing and wiring.
- 3-3312.0354 eli-m-c1060f6ba73154ebaa44d5ef Only for source configuration configuration-1c8a51fe4b0759651da3bc38: K-C10 · 1 MN configuration; selected configuration must be matched before display.; BS1: cable Ø4–6.5 mm; BS2: Ø≥6.5 mm. Match bayonet/threaded sensor connection, sealing and wiring.
Mounting
- 1-EDO3/50KN eli-m-0ec346c4e9c0b36955545d9b Only for source configuration configuration-55a98f99bd0d0593c2edc147: K-C10 · 50 kN configuration; selected configuration must be matched before display.; Match nominal capacity, contact geometry and installation; not a tension eye.
- 1-EDO3/100KN eli-m-077d8fb00ba23099739a31ec Only for source configuration configuration-09c47c76ba2210f2dd3cf0cf: K-C10 · 250 kN configuration; selected configuration must be matched before display.; Match nominal capacity, contact geometry and installation; not a tension eye.
- 1-EDO3/500KN eli-m-b21a68a1e991954793fc8431 Only for source configuration configuration-a27443e334e84d66dbb0b61b: K-C10 · 500 kN configuration; selected configuration must be matched before display.; Match nominal capacity, contact geometry and installation; not a tension eye.
- 1-EDO3/1MN eli-m-68c57012e36ac935d720630d Only for source configuration configuration-1c8a51fe4b0759651da3bc38: K-C10 · 1 MN configuration; selected configuration must be matched before display.; Match nominal capacity, contact geometry and installation; not a tension eye.
The industries we serve
Frequently asked questions
Answers to the most common questions about our products and services
C10 is designed to measure compressive force. Select another transducer when tensile-force measurement is required.
No. The datasheet qualifies IP68 by the fixed-cable option and nominal force of at least 25 kN. Check the selected configuration.
It provides two electrically isolated measuring bridges in one sensing body for connection to separate amplifiers.
C10 offers different connector and cable options. Match the connection code to the amplifier and required protection.
Some C10 models have a rated output above 4 mV/V; the improvement description specifies this from 25 kN capacity. Select a bridge input and excitation matching the actual model sensitivity to avoid clipping; do not apply one value to every capacity.