K-C10 · 25 kN
From the C10 series
C10: sensors and measurement devices by HBK for force.
Capacity and selected options are specific to this record. Remaining options: HBK-K-C10-v1
Download the datasheet (opens in a new tab) This series on the HBK site (opens in a new tab)
Technical specification
Every engineering figure, laid out to scan quickly
| Nominal force capacity | 25000 N |
|---|---|
| Ordering options and constraints | K-C10 — capacity: 2.5 kN, 5 kN, 10 kN, 25 kN, 50 kN, 100 kN, 250 kN, 500 kN, 1 MN; bridge: SB, DB; rated_output: N, J; calibration: 50%, 100%; teds: Not selected, T; mechanical_design: W adapter, N flange; plug_protection: P, U; electrical_connection: B, G, K (6 m), V (15 m), 00A4 (VAIO); force_application: O, L; cable_plug: Y, F, Q, N, P, M, X; integrated_amplifier: N, VAIO; constraints: [{"when": {"teds": "T"}, "deny": {"integrated_amplifier": ["VAIO"]}, "reason": "TEDS and the integrated VAIO amplifier are mutually exclusive in the official configuration."}, {"when": {"integrated_amplifier": "VAIO"}, "allow": {"electrical_connection": "00A4 (VAIO)"}, "reason": "The VAIO connection is reserved for the integrated-amplifier option."}] |
| Selected configuration options | 25 kN nominal force capacity |
Compatible accessories
Cables
- K-CAB-F-B eli-m-77598bb679b1cefd06e0eb15 Only for source configuration configuration-1c8a51fe4b0759651da3bc38: K-C10 · 1 MN configuration; selected configuration must be matched before display.; Only for the listed passive SG sensor socket; fixed-cable K/V and VAIO/4-pin IO-Link are excluded. Select the amplifier end and validate carrier-frequency precision, EMC and calibration with the cable length.; 0131: static/dynamic bend radius 22/50 mm, -50…80 °C, 280 Ω/km; high-precision use may require low carrier frequency and stable temperature. 0157: 37/75 mm, -50…85 °C, 78 Ω/km. 139B: 75 mm static, no drag chain; -30…70 °C stationary / -5…50 °C moving; incompatible with P/M ends.; IP protection depends on the actual sensor socket, seal and connector locking; a generic connector IP rating is not the assembled sensor IP rating.
- K-CAB-F-G eli-m-cb053e0dbafcb9f5c97d35d2 Only for source configuration configuration-1c8a51fe4b0759651da3bc38: K-C10 · 1 MN configuration; selected configuration must be matched before display.; Only for the listed passive SG sensor socket; fixed-cable K/V and VAIO/4-pin IO-Link are excluded. Select the amplifier end and validate carrier-frequency precision, EMC and calibration with the cable length.; 0131: static/dynamic bend radius 22/50 mm, -50…80 °C, 280 Ω/km; high-precision use may require low carrier frequency and stable temperature. 0157: 37/75 mm, -50…85 °C, 78 Ω/km. 139B: 75 mm static, no drag chain; -30…70 °C stationary / -5…50 °C moving; incompatible with P/M ends.; IP protection depends on the actual sensor socket, seal and connector locking; a generic connector IP rating is not the assembled sensor IP rating.
- K-CAB-F-L eli-m-da3a2435c758af1a6a732a76 Only for source configuration configuration-1c8a51fe4b0759651da3bc38: K-C10 · 1 MN configuration; selected configuration must be matched before display.; Only for the listed passive SG sensor socket; fixed-cable K/V and VAIO/4-pin IO-Link are excluded. Select the amplifier end and validate carrier-frequency precision, EMC and calibration with the cable length.; 0131: static/dynamic bend radius 22/50 mm, -50…80 °C, 280 Ω/km; high-precision use may require low carrier frequency and stable temperature. 0157: 37/75 mm, -50…85 °C, 78 Ω/km. 139B: 75 mm static, no drag chain; -30…70 °C stationary / -5…50 °C moving; incompatible with P/M ends.; IP protection depends on the actual sensor socket, seal and connector locking; a generic connector IP rating is not the assembled sensor IP rating.
- 1-KAB157-3 eli-m-a68247a3773360ad7d0177e8 Only for source configuration configuration-1c8a51fe4b0759651da3bc38: K-C10 · 1 MN configuration; selected configuration must be matched before display.; The threaded cable is rated differently in U10M and C10 documents; do not assign a universal IP class. Check socket, locked connector and end wiring.
- 1-KAB158-3 eli-m-9dd63f28a1bb0c811ab235e7 Only for source configuration configuration-1c8a51fe4b0759651da3bc38: K-C10 · 1 MN configuration; selected configuration must be matched before display.; The threaded cable is rated differently in U10M and C10 documents; do not assign a universal IP class. Check socket, locked connector and end wiring.
- 1-CON/BS1 eli-m-fa3e0808051d0b0eb0fd786d Only for source configuration configuration-1c8a51fe4b0759651da3bc38: K-C10 · 1 MN configuration; selected configuration must be matched before display.; BS1: cable Ø4–6.5 mm; BS2: Ø≥6.5 mm. Match bayonet/threaded sensor connection, sealing and wiring.
- 1-CON/BS2 eli-m-d369711675c68ed790d49233 Only for source configuration configuration-1c8a51fe4b0759651da3bc38: K-C10 · 1 MN configuration; selected configuration must be matched before display.; BS1: cable Ø4–6.5 mm; BS2: Ø≥6.5 mm. Match bayonet/threaded sensor connection, sealing and wiring.
- 3-3312.0354 eli-m-c1060f6ba73154ebaa44d5ef Only for source configuration configuration-1c8a51fe4b0759651da3bc38: K-C10 · 1 MN configuration; selected configuration must be matched before display.; BS1: cable Ø4–6.5 mm; BS2: Ø≥6.5 mm. Match bayonet/threaded sensor connection, sealing and wiring.
Mounting
- 1-EDO3/50KN eli-m-0ec346c4e9c0b36955545d9b Only for source configuration configuration-55a98f99bd0d0593c2edc147: K-C10 · 50 kN configuration; selected configuration must be matched before display.; Match nominal capacity, contact geometry and installation; not a tension eye.
- 1-EDO3/100KN eli-m-077d8fb00ba23099739a31ec Only for source configuration configuration-09c47c76ba2210f2dd3cf0cf: K-C10 · 250 kN configuration; selected configuration must be matched before display.; Match nominal capacity, contact geometry and installation; not a tension eye.
- 1-EDO3/500KN eli-m-b21a68a1e991954793fc8431 Only for source configuration configuration-a27443e334e84d66dbb0b61b: K-C10 · 500 kN configuration; selected configuration must be matched before display.; Match nominal capacity, contact geometry and installation; not a tension eye.
- 1-EDO3/1MN eli-m-68c57012e36ac935d720630d Only for source configuration configuration-1c8a51fe4b0759651da3bc38: K-C10 · 1 MN configuration; selected configuration must be matched before display.; Match nominal capacity, contact geometry and installation; not a tension eye.
The industries we serve
Get a quote or advice
Tell us what you need and an engineer will come back to you.