Skip to content

C11-50N

From the C11 series

C11: sensors and measurement devices by HBK for force.

Force range
0–50 N
This series on the HBK site (opens in a new tab)

Technical specification

Every engineering figure, laid out to scan quickly

Technical specification for C11-50N
Force range 0–50 N
Accuracy (% FSO) 0.5 %
Interfaces ethernet
interface_specification Digital I/O
quantity_specification 50 N rated capacity = 50 N (5.0986 kg mass equivalent at standard gravity); compression
ADC sampling rate 450 samples/s
source_sampling_rate_basis ClipX fixed internal sampling rate; verify the configured filter and usable output bandwidth
ADC sampling rate 19200 samples/s
source_sampling_rate_basis MX840B maximum per-channel sample rate; sensor mechanics and filter settings can reduce usable bandwidth
ADC sampling rate 40000 samples/s
source_sampling_rate_basis DMP41 selectable result rate, intended for reference and calibration measurements
Interfaces ethercat
interface_specification RS422 / RS485
interface_specification Analog 0-10V
Interfaces profinet
Request a quote for this product

The industries we serve

Get a quote or advice

Tell us what you need and an engineer will come back to you.

Request a quote for this product
What would you like to ask for?

Email or phone — one of them is enough

Email or phone — one of them is enough

0 of 500 words