Skip to content

Shared technical specifications for the series

Properties every model in the series has. What differs is in the models table below.

Technical specification for C6B
Ordering options and constraints K-C6B — capacity: 45 klbf, 112 klbf, 225 klbf, 450 klbf, 1124 klbf, 2248 klbf; output_signal: mV/V (passive strain gauge), Voltage (0…10V), Current (4-20mA); mechanical_interfaces: Hole through type, Column type; height_without_accessories: 2.36 in, 3.94 in, 7.09 in, 9.45 in; diameter_without_cable_or_plug: 6.25983 in, 3.1496 in; constraints: []

Range across models

The span covered by the models of the series together — not the range of each model.

Range across the models of C6B
Force range 0–500000 N
Nominal force capacity 200000–10000000 N

Models in the series

One column per model: what differs between the models of the series.

Models of C6B compared by parameter
Parameter 1-C6B/10MN eli-m-879bf90df1d5e827ff39bd3b 1-C6B/1MN eli-m-1718d99e865715d272896a73 1-C6B/200KN eli-m-2677698463b741126cd5b885 1-C6B/2MN eli-m-2c94f31a3a266decea55498e 1-C6B/500KN eli-m-1333d1d9a1888a13bbec74de 1-C6B/5MN eli-m-1461fdb8a56dd3cf28fa4b77 K-C6B · 1 MN eli-m-956221e40e0273621c18aedb K-C6B · 10 MN eli-m-ca25a8f3c2f22ccb925cdf1d K-C6B · 2 MN eli-m-f435c28dae57393894730c85 K-C6B · 200 kN eli-m-4e2e07193d641e3877fd70d7 K-C6B · 5 MN eli-m-1871e5c7fcf75faf5968f57d K-C6B · 500 kN eli-m-a9ef6f06b528b32d9bfc4826
Force range 0–10000000 N 0–1000000 N 0–200000 N 0–2000000 N 0–500000 N 0–5000000 N Not specified Not specified Not specified Not specified Not specified Not specified
quantity_specification Maximum capacity (nominal load): 2248 klbf; Output signal: mV/V (passive strain gauge); Mechanical interfaces: Column type; Height (without accessories): 9.45 in; Diameter (without cable or plug): 10.51179 in Maximum capacity (nominal load): 225 klbf; Output signal: mV/V (passive strain gauge); Mechanical interfaces: Hole through type; Height (without accessories): 3.94 in; Diameter (without cable or plug): 7.44093 in Maximum capacity (nominal load): 45 klbf; Output signal: mV/V (passive strain gauge); Mechanical interfaces: Hole through type; Height (without accessories): 2.36 in; Diameter (without cable or plug): 1.358265 in Maximum capacity (nominal load): 450 klbf; Output signal: mV/V (passive strain gauge); Mechanical interfaces: Hole through type; Height (without accessories): 3.94 in; Diameter (without cable or plug): 1.594485 in Maximum capacity (nominal load): 112 klbf; Output signal: mV/V (passive strain gauge); Mechanical interfaces: Hole through type; Height (without accessories): 2.36 in; Diameter (without cable or plug): 0.570865 in Maximum capacity (nominal load): 1124 klbf; Output signal: mV/V (passive strain gauge); Mechanical interfaces: Column type; Height (without accessories): 7.09 in; Diameter (without cable or plug): 7.44093 in Not specified Not specified Not specified Not specified Not specified Not specified
interface_specification Unknown Unknown Unknown Unknown Unknown Unknown Not specified Not specified Not specified Not specified Not specified Not specified
Force range Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified
Selected configuration options Not specified Not specified Not specified Not specified Not specified Not specified 1 MN nominal force capacity 10 MN nominal force capacity 2 MN nominal force capacity 200 kN nominal force capacity 5 MN nominal force capacity 500 kN nominal force capacity
Nominal force capacity Not specified Not specified Not specified Not specified Not specified Not specified 1000000 N 10000000 N 2000000 N 200000 N 5000000 N 500000 N
Status Active Active Active Active Active Active Active Active Active Active Active Active
Datasheet PDF — K-C6B · 1 MN (opens in a new tab) PDF — K-C6B · 10 MN (opens in a new tab) PDF — K-C6B · 2 MN (opens in a new tab) PDF — K-C6B · 200 kN (opens in a new tab) PDF — K-C6B · 5 MN (opens in a new tab) PDF — K-C6B · 500 kN (opens in a new tab)

Compatible accessories

Cables

  • K-CAB-F-B eli-m-77598bb679b1cefd06e0eb15 Only for source configuration configuration-29b77d7d94063a97973d9fe6: K-C6B · 10 MN configuration; selected configuration must be matched before display.; Only for the listed passive SG sensor socket; fixed-cable K/V and VAIO/4-pin IO-Link are excluded. Select the amplifier end and validate carrier-frequency precision, EMC and calibration with the cable length.; 0131: static/dynamic bend radius 22/50 mm, -50…80 °C, 280 Ω/km; high-precision use may require low carrier frequency and stable temperature. 0157: 37/75 mm, -50…85 °C, 78 Ω/km. 139B: 75 mm static, no drag chain; -30…70 °C stationary / -5…50 °C moving; incompatible with P/M ends.; IP protection depends on the actual sensor socket, seal and connector locking; a generic connector IP rating is not the assembled sensor IP rating.
  • K-CAB-F-G eli-m-cb053e0dbafcb9f5c97d35d2 Only for source configuration configuration-29b77d7d94063a97973d9fe6: K-C6B · 10 MN configuration; selected configuration must be matched before display.; Only for the listed passive SG sensor socket; fixed-cable K/V and VAIO/4-pin IO-Link are excluded. Select the amplifier end and validate carrier-frequency precision, EMC and calibration with the cable length.; 0131: static/dynamic bend radius 22/50 mm, -50…80 °C, 280 Ω/km; high-precision use may require low carrier frequency and stable temperature. 0157: 37/75 mm, -50…85 °C, 78 Ω/km. 139B: 75 mm static, no drag chain; -30…70 °C stationary / -5…50 °C moving; incompatible with P/M ends.; IP protection depends on the actual sensor socket, seal and connector locking; a generic connector IP rating is not the assembled sensor IP rating.
  • K-CAB-F-L eli-m-da3a2435c758af1a6a732a76 Only for source configuration configuration-29b77d7d94063a97973d9fe6: K-C6B · 10 MN configuration; selected configuration must be matched before display.; Only for the listed passive SG sensor socket; fixed-cable K/V and VAIO/4-pin IO-Link are excluded. Select the amplifier end and validate carrier-frequency precision, EMC and calibration with the cable length.; 0131: static/dynamic bend radius 22/50 mm, -50…80 °C, 280 Ω/km; high-precision use may require low carrier frequency and stable temperature. 0157: 37/75 mm, -50…85 °C, 78 Ω/km. 139B: 75 mm static, no drag chain; -30…70 °C stationary / -5…50 °C moving; incompatible with P/M ends.; IP protection depends on the actual sensor socket, seal and connector locking; a generic connector IP rating is not the assembled sensor IP rating.

The industries we serve

Frequently asked questions

Answers to the most common questions about our products and services

C6B is designed for compression. Selection includes nominal force and suitable force-introduction accessories, not just transducer dimensions.

No. The table specifies IP68 for fixed cable, IP67 for the bayonet-connector option when connected, and IP64 for the threaded-connector option. The stated IP68 test is a 1 m water column for 100 hours.

Yes. The table separates hardened compression plates, the ZL load button and ZK spherical cap. Use the value for the mounting arrangement rather than assigning the best value to every model.

The datasheet separates the transducer without an integrated amplifier from amplified configurations. Select the order code and acquisition electronics for the actual signal path.

No. Natural frequency is a mechanical property that varies with capacity. Sampling rate also depends on the amplifier and DAQ. Do not present natural frequency as system sampling rate.

Didn't find the answer you were looking for?

Talk to an expert

More information

Get a quote or advice

Tell us what you need and an engineer will come back to you.

Request a quote for this product
What would you like to ask for?

Email or phone — one of them is enough

Email or phone — one of them is enough

0 of 500 words