Skip to content

K-C9C · 1 kN

From the C9C series

C9C: sensors and measurement devices by HBK for force.

Capacity and selected options are specific to this record. Remaining options: HBK-K-C9C-v1

Download the datasheet (opens in a new tab) This series on the HBK site (opens in a new tab)

Technical specification

Every engineering figure, laid out to scan quickly

Technical specification for K-C9C · 1 kN
Nominal force capacity 1000 N
Ordering options and constraints K-C9C — capacity: 50 N, 100 N, 200 N, 0.5 kN, 1 kN, 2 kN, 5 kN, 10 kN, 20 kN, 50 kN; cable_length: 1.5 m, 3 m, 5 m, 6 m, 7 m, 12 m; output: mV/V, 0…10 V, 4…20 mA, IO-Link, VA1, VA2, VAIO; connector: Y, F, Q, N, M, M12; teds: Not selected, T; mechanical_interface: Spherical load introduction; constraints: [{"when": {"output": ["VA1", "VA2", "VAIO"]}, "allow": {"cable_length": ["1.5 m", "3 m"]}, "reason": "HBK limits inline-amplifier variants to the documented short cable lengths."}, {"when": {"teds": "T"}, "deny": {"connector": "M12", "output": ["VA1", "VA2", "VAIO"]}, "reason": "TEDS is available with plug variants, not free-end/M12 or inline-amplifier variants."}]
Selected configuration options 1 kN nominal force capacity
Request a quote for this product

Compatible accessories

Cables

  • 1-KAB168-5 eli-m-046536f442a5e67f7cc58f5d Only for source configuration configuration-a30712210efda5622e8f81c8: K-C9C · 50 kN configuration; selected configuration must be matched before display.; For the VA1 voltage or VA2 current inline amplifier, not a passive bridge or 4-pin VAIO IO-Link port. This is the amplifier-output cable, separate from the factory sensor-to-amplifier lead.
  • 1-KAB168-20 eli-m-5e112d12af4c97508e292545 Only for source configuration configuration-a30712210efda5622e8f81c8: K-C9C · 50 kN configuration; selected configuration must be matched before display.; For the VA1 voltage or VA2 current inline amplifier, not a passive bridge or 4-pin VAIO IO-Link port. This is the amplifier-output cable, separate from the factory sensor-to-amplifier lead.

Mounting

  • 1-EDO9/20kN eli-m-85fcdee08d110821ffa6d4d7 Only for source configuration configuration-2aab71ba4a270c6010b2d2d5: K-C9C · 20 kN configuration; selected configuration must be matched before display.; Match nominal capacity and the specified load introduction; not a tensile knuckle eye.
  • 1-EDO9/50kN eli-m-9344c08b5f7bd53bc57b286d Only for source configuration configuration-a30712210efda5622e8f81c8: K-C9C · 50 kN configuration; selected configuration must be matched before display.; Match nominal capacity and the specified load introduction; not a tensile knuckle eye.

The industries we serve

Get a quote or advice

Tell us what you need and an engineer will come back to you.

Request a quote for this product
What would you like to ask for?

Email or phone — one of them is enough

Email or phone — one of them is enough

0 of 500 words