Parameter PACEline CMC eli-m-3bdbe99351f5500929396dbf PACEline CMC-120kN eli-m-8def6ee94a1288d39b39612e PACEline CMC-20kN eli-m-60acf3954b4c0a089e55417a PACEline CMC-25kN eli-m-d5956a3ab1f989c528868635 PACEline CMC-50kN eli-m-f6593857fb20607204527dc0 PACEline CMC-5kN eli-m-ac59ea59e686cc3843c3ba00 PACEline CMC-70kN eli-m-6c69c3f8289cefe03579fb33
interface_specification Unknown Analog 0-10V Analog 0-10V Analog 0-10V Analog 0-10V Analog 0-10V Analog 0-10V
quantity_specification Configurable family; exact public ordering-code table not exposed on the current HBK page. 120 kN rated capacity = 120 kN (12.2366 t mass equivalent at standard gravity); compression 20 kN rated capacity = 20 kN (2.0394 t mass equivalent at standard gravity); compression 25 kN rated capacity = 25 kN (2.5493 t mass equivalent at standard gravity); compression 50 kN rated capacity = 50 kN (5.0986 t mass equivalent at standard gravity); compression 5 kN rated capacity = 5 kN (509.8581 kg mass equivalent at standard gravity); compression 70 kN rated capacity = 70 kN (7.138 t mass equivalent at standard gravity); compression
Force range Not specified 0–120000 N 0–20000 N 0–25000 N 0–50000 N 0–5000 N 0–70000 N
Force range Not specified Not specified Not specified Not specified Not specified Not specified Not specified
Status Active Active Active Active Active Active Active

The industries we serve

Frequently asked questions

Answers to the most common questions about our products and services

CMC combines a piezoelectric force transducer, cable and charge amplifier. The manufacturer describes chain calibration from force in newtons to voltage, unlike three independently selected components without chain calibration.

The manufacturer specifies a second measurement range with fivefold amplification. This is an amplifier-range selection, not an increase in the head’s permissible force.

The amplifier table documents a ±10 V output. The head’s charge is processed by the amplifier, so acquisition must match the chain output.

No. The table specifies 10 kHz at −3 dB and 5 kHz at −1 dB. These are amplifier frequency-response properties; DAQ sampling rate is separate.

No. The datasheet specifies accuracy class 0.5 for the documented CMC chain. Replacing a cable or amplifier does not establish that the new combination retains its chain calibration and performance.

Didn't find the answer you were looking for?

Talk to an expert

More information

Get a quote or advice

Tell us what you need and an engineer will come back to you.

Request a quote for this product
What would you like to ask for?

Email or phone — one of them is enough

Email or phone — one of them is enough

0 of 500 words