Parameter 1-CSW/1KN eli-m-b85acd03c794da23372f0781 1-CSW/2KN eli-m-dbfec1e2a108cb3e802684b9 1-CSW/3KN eli-m-e1f6ea20875c42366476c549 1-CSW/4.5KN eli-m-d1d532139d78197a91fcf208 1-CSW/8KN eli-m-15ae516da96a30f152bfa2b0
quantity_specification Maximum capacity (nominal load): 225 lbf; Height (without accessories): 0.138 in; Diameter (without cable or plug): 0.62992 in Maximum capacity (nominal load): 450 lbf; Height (without accessories): 0.138 in; Diameter (without cable or plug): 0.7874 in Maximum capacity (nominal load): 674 lbf; Height (without accessories): 0.138 in; Diameter (without cable or plug): 0.94488 in Maximum capacity (nominal load): 11 klbf; Height (without accessories): 0.157 in; Diameter (without cable or plug): 1.1811 in Maximum capacity (nominal load): 1.8 klbf; Height (without accessories): 0.197 in; Diameter (without cable or plug): 1.41732 in
interface_specification Unknown Unknown Unknown Unknown Unknown
Force range 0–1000 N 0–2000 N 0–3000 N 0–4500 N 0–8000 N
Force range Not specified Not specified Not specified Not specified Not specified
Status Active Active Active Active Active

The industries we serve

Frequently asked questions

Answers to the most common questions about our products and services

CSW is a piezoelectric shear-force washer. Its ring shape does not establish an axial compression measurement function.

The manufacturer identifies parallel sensor connection for a measuring platform. Distinguish summed signals from independent acquisition of each sensor.

No. The table separates 1, 2, 3, 4.5 and 8 kN versions with different dimensions. Nominal-force selection also requires mechanical fit.

The datasheet specifies IP65 and corrosion-resistant materials. Select the remaining charge-chain components for the system environment.

The manufacturer requires calibration in the installed arrangement. A typical table sensitivity does not replace calibration of the washer in the structure and intended preload conditions. Record the actual configuration conversion factor in the charge amplifier or acquisition system.

Didn't find the answer you were looking for?

Talk to an expert

More information

Get a quote or advice

Tell us what you need and an engineer will come back to you.

Request a quote for this product
What would you like to ask for?

Email or phone — one of them is enough

Email or phone — one of them is enough

0 of 500 words