Skip to content

Prewired Strain

Prewired: sensors and measurement devices by HBK for strain.

Visit the HBK site (opens in a new tab)

Shared technical specifications for the series

Properties every model in the series has. What differs is in the models table below.

Range across models

The span covered by the models of the series together — not the range of each model.

Range across the models of Prewired
Gauge resistance 350 Ω
gauge_carrier_width 4.7–22.9 mm
gauge_carrier_length 6.6–18 mm
Grid length 1.5–10 mm
Grid width 1.2–6.5 mm

Models in the series

One column per model: what differs between the models of the series.

Models of Prewired compared by parameter
Parameter 1-LY41-1.5/120V1 eli-m-f4018abccaeac654b2433138 1-LY41-10/350V1 eli-m-1faa7c6ed10157640a40d18c 1-LY41-3/350V3 eli-m-c9ab9258cfceee9846e53b58 1-LY41-6/120V1 eli-m-27cff264b2ebaae58511a6c0 1-LY41-6/350V1 eli-m-7d7b3c162c2210b28e321072 1-LY41-6/350V3 eli-m-7aa92bdb6dfbadbe2aff8141 1-LY91-1.5/350V3 eli-m-650a906ac28ab63ff0166e2e 1-RY81-3/350V1 eli-m-3d47446abc8221f7530fb077 1-RY81-6/350V1 eli-m-f5ea2b90d047dea1a2823972 1-TY11-6/350V1 eli-m-ba8cdbf0f7fed642a9f79703 1-XY41-6/350H3 eli-m-f837dd77dfb2b013ddd3d88f
Gauge resistance 120 Ω 350 Ω 350 Ω 120 Ω 350 Ω 350 Ω 350 Ω 350 Ω 350 Ω 350 Ω 350 Ω
source_solder_terminal_or_cable_connection Pre-wired (TPE-insulated ribbon cable) Pre-wired (TPE-insulated ribbon cable) Pre-wired (TPE-insulated ribbon cable) Pre-wired (TPE-insulated ribbon cable) Pre-wired (TPE-insulated ribbon cable) Pre-wired (TPE-insulated ribbon cable) Pre-wired (TPE-insulated ribbon cable) Pre-wired (TPE-insulated ribbon cable) Pre-wired (TPE-insulated ribbon cable) Pre-wired (TPE-insulated ribbon cable) Pre-wired (TPE-insulated ribbon cable)
gauge_carrier_width 5 mm 8 mm 5.9 mm 5.9 mm 5.9 mm 5.9 mm 4.7 mm 14.6 mm 22.9 mm 18 mm 12.2 mm
source_linearity_basis Use the exact HBK gauge factor, transverse sensitivity and batch calibration values supplied with the ordering code. Use the exact HBK gauge factor, transverse sensitivity and batch calibration values supplied with the ordering code. Use the exact HBK gauge factor, transverse sensitivity and batch calibration values supplied with the ordering code. Use the exact HBK gauge factor, transverse sensitivity and batch calibration values supplied with the ordering code. Use the exact HBK gauge factor, transverse sensitivity and batch calibration values supplied with the ordering code. Use the exact HBK gauge factor, transverse sensitivity and batch calibration values supplied with the ordering code. Use the exact HBK gauge factor, transverse sensitivity and batch calibration values supplied with the ordering code. Use the exact HBK gauge factor, transverse sensitivity and batch calibration values supplied with the ordering code. Use the exact HBK gauge factor, transverse sensitivity and batch calibration values supplied with the ordering code. Use the exact HBK gauge factor, transverse sensitivity and batch calibration values supplied with the ordering code. Use the exact HBK gauge factor, transverse sensitivity and batch calibration values supplied with the ordering code.
quantity_specification Strain gauge; Linear; Constantan (ca 2.0); Standard (up to 200°C); Ferritic steel (10.8 ppm/K; 6.0 ppm/°F); Pre-wired (TPE-insulated ribbon cable); Bondable Strain gauge; Linear; Constantan (ca 2.0); Standard (up to 200°C); Ferritic steel (10.8 ppm/K; 6.0 ppm/°F); Pre-wired (TPE-insulated ribbon cable); Bondable Strain gauge; Linear; Constantan (ca 2.0); Standard (up to 200°C); Ferritic steel (10.8 ppm/K; 6.0 ppm/°F); Pre-wired (TPE-insulated ribbon cable); Bondable Strain gauge; Linear; Constantan (ca 2.0); Standard (up to 200°C); Ferritic steel (10.8 ppm/K; 6.0 ppm/°F); Pre-wired (TPE-insulated ribbon cable); Bondable Strain gauge; Linear; Constantan (ca 2.0); Standard (up to 200°C); Ferritic steel (10.8 ppm/K; 6.0 ppm/°F); Pre-wired (TPE-insulated ribbon cable); Bondable Strain gauge; Linear; Constantan (ca 2.0); Standard (up to 200°C); Ferritic steel (10.8 ppm/K; 6.0 ppm/°F); Pre-wired (TPE-insulated ribbon cable); Bondable Strain gauge; Linear; Constantan (ca 2.0); Standard (up to 200°C); Ferritic steel (10.8 ppm/K; 6.0 ppm/°F); Pre-wired (TPE-insulated ribbon cable); Bondable Strain gauge; 3-grid rosette; Constantan (ca 2.0); Standard (up to 200°C); Ferritic steel (10.8 ppm/K; 6.0 ppm/°F); Pre-wired (TPE-insulated ribbon cable); Bondable Strain gauge; 3-grid rosette; Constantan (ca 2.0); Standard (up to 200°C); Ferritic steel (10.8 ppm/K; 6.0 ppm/°F); Pre-wired (TPE-insulated ribbon cable); Bondable Strain gauge; T rosette; Constantan (ca 2.0); Standard (up to 200°C); Ferritic steel (10.8 ppm/K; 6.0 ppm/°F); Pre-wired (TPE-insulated ribbon cable); Bondable Strain gauge; Shear/torsion; Constantan (ca 2.0); Standard (up to 200°C); Ferritic steel (10.8 ppm/K; 6.0 ppm/°F); Pre-wired (TPE-insulated ribbon cable); Bondable
source_temperature_range Standard (up to 200°C) Standard (up to 200°C) Standard (up to 200°C) Standard (up to 200°C) Standard (up to 200°C) Standard (up to 200°C) Standard (up to 200°C) Standard (up to 200°C) Standard (up to 200°C) Standard (up to 200°C) Standard (up to 200°C)
source_repeatability_basis No unsupported standalone repeatability is inferred; installed repeatability is verified after bonding and shunt calibration. No unsupported standalone repeatability is inferred; installed repeatability is verified after bonding and shunt calibration. No unsupported standalone repeatability is inferred; installed repeatability is verified after bonding and shunt calibration. No unsupported standalone repeatability is inferred; installed repeatability is verified after bonding and shunt calibration. No unsupported standalone repeatability is inferred; installed repeatability is verified after bonding and shunt calibration. No unsupported standalone repeatability is inferred; installed repeatability is verified after bonding and shunt calibration. No unsupported standalone repeatability is inferred; installed repeatability is verified after bonding and shunt calibration. No unsupported standalone repeatability is inferred; installed repeatability is verified after bonding and shunt calibration. No unsupported standalone repeatability is inferred; installed repeatability is verified after bonding and shunt calibration. No unsupported standalone repeatability is inferred; installed repeatability is verified after bonding and shunt calibration. No unsupported standalone repeatability is inferred; installed repeatability is verified after bonding and shunt calibration.
source_geometry Linear Linear Linear Linear Linear Linear Linear 3-grid rosette 3-grid rosette T rosette Shear/torsion
gauge_carrier_length 7 mm 18 mm 10.9 mm 13.9 mm 13.9 mm 13.9 mm 6.6 mm 9.699999999999999 mm 13.1 mm 12 mm 16 mm
Grid length 1.5 mm 10 mm 3 mm 6 mm 6 mm 6 mm 1.5 mm 3 mm 6 mm 6 mm 6 mm
interface_specification Unknown Unknown Unknown Unknown Unknown Unknown Unknown Unknown Unknown Unknown Unknown
Grid width 1.2 mm 5 mm 2.5 mm 2.7 mm 2.8 mm 2.8 mm 2 mm 1.2 mm 2.8 mm 6.5 mm 6 mm
Status Active Active Active Active Active Active Active Active Active Active Active