Shared technical specifications for the series
Properties every model in the series has. What differs is in the models table below.
Range across models
The span covered by the models of the series together — not the range of each model.
| Gauge resistance | 350 Ω |
|---|---|
| gauge_carrier_width | 4.7–22.9 mm |
| gauge_carrier_length | 6.6–18 mm |
| Grid length | 1.5–10 mm |
| Grid width | 1.2–6.5 mm |
Models in the series
One column per model: what differs between the models of the series.
| Parameter | 1-LY41-1.5/120V1 eli-m-f4018abccaeac654b2433138 | 1-LY41-10/350V1 eli-m-1faa7c6ed10157640a40d18c | 1-LY41-3/350V3 eli-m-c9ab9258cfceee9846e53b58 | 1-LY41-6/120V1 eli-m-27cff264b2ebaae58511a6c0 | 1-LY41-6/350V1 eli-m-7d7b3c162c2210b28e321072 | 1-LY41-6/350V3 eli-m-7aa92bdb6dfbadbe2aff8141 | 1-LY91-1.5/350V3 eli-m-650a906ac28ab63ff0166e2e | 1-RY81-3/350V1 eli-m-3d47446abc8221f7530fb077 | 1-RY81-6/350V1 eli-m-f5ea2b90d047dea1a2823972 | 1-TY11-6/350V1 eli-m-ba8cdbf0f7fed642a9f79703 | 1-XY41-6/350H3 eli-m-f837dd77dfb2b013ddd3d88f |
|---|---|---|---|---|---|---|---|---|---|---|---|
| Gauge resistance | 120 Ω | 350 Ω | 350 Ω | 120 Ω | 350 Ω | 350 Ω | 350 Ω | 350 Ω | 350 Ω | 350 Ω | 350 Ω |
| source_solder_terminal_or_cable_connection | Pre-wired (TPE-insulated ribbon cable) | Pre-wired (TPE-insulated ribbon cable) | Pre-wired (TPE-insulated ribbon cable) | Pre-wired (TPE-insulated ribbon cable) | Pre-wired (TPE-insulated ribbon cable) | Pre-wired (TPE-insulated ribbon cable) | Pre-wired (TPE-insulated ribbon cable) | Pre-wired (TPE-insulated ribbon cable) | Pre-wired (TPE-insulated ribbon cable) | Pre-wired (TPE-insulated ribbon cable) | Pre-wired (TPE-insulated ribbon cable) |
| gauge_carrier_width | 5 mm | 8 mm | 5.9 mm | 5.9 mm | 5.9 mm | 5.9 mm | 4.7 mm | 14.6 mm | 22.9 mm | 18 mm | 12.2 mm |
| source_linearity_basis | Use the exact HBK gauge factor, transverse sensitivity and batch calibration values supplied with the ordering code. | Use the exact HBK gauge factor, transverse sensitivity and batch calibration values supplied with the ordering code. | Use the exact HBK gauge factor, transverse sensitivity and batch calibration values supplied with the ordering code. | Use the exact HBK gauge factor, transverse sensitivity and batch calibration values supplied with the ordering code. | Use the exact HBK gauge factor, transverse sensitivity and batch calibration values supplied with the ordering code. | Use the exact HBK gauge factor, transverse sensitivity and batch calibration values supplied with the ordering code. | Use the exact HBK gauge factor, transverse sensitivity and batch calibration values supplied with the ordering code. | Use the exact HBK gauge factor, transverse sensitivity and batch calibration values supplied with the ordering code. | Use the exact HBK gauge factor, transverse sensitivity and batch calibration values supplied with the ordering code. | Use the exact HBK gauge factor, transverse sensitivity and batch calibration values supplied with the ordering code. | Use the exact HBK gauge factor, transverse sensitivity and batch calibration values supplied with the ordering code. |
| quantity_specification | Strain gauge; Linear; Constantan (ca 2.0); Standard (up to 200°C); Ferritic steel (10.8 ppm/K; 6.0 ppm/°F); Pre-wired (TPE-insulated ribbon cable); Bondable | Strain gauge; Linear; Constantan (ca 2.0); Standard (up to 200°C); Ferritic steel (10.8 ppm/K; 6.0 ppm/°F); Pre-wired (TPE-insulated ribbon cable); Bondable | Strain gauge; Linear; Constantan (ca 2.0); Standard (up to 200°C); Ferritic steel (10.8 ppm/K; 6.0 ppm/°F); Pre-wired (TPE-insulated ribbon cable); Bondable | Strain gauge; Linear; Constantan (ca 2.0); Standard (up to 200°C); Ferritic steel (10.8 ppm/K; 6.0 ppm/°F); Pre-wired (TPE-insulated ribbon cable); Bondable | Strain gauge; Linear; Constantan (ca 2.0); Standard (up to 200°C); Ferritic steel (10.8 ppm/K; 6.0 ppm/°F); Pre-wired (TPE-insulated ribbon cable); Bondable | Strain gauge; Linear; Constantan (ca 2.0); Standard (up to 200°C); Ferritic steel (10.8 ppm/K; 6.0 ppm/°F); Pre-wired (TPE-insulated ribbon cable); Bondable | Strain gauge; Linear; Constantan (ca 2.0); Standard (up to 200°C); Ferritic steel (10.8 ppm/K; 6.0 ppm/°F); Pre-wired (TPE-insulated ribbon cable); Bondable | Strain gauge; 3-grid rosette; Constantan (ca 2.0); Standard (up to 200°C); Ferritic steel (10.8 ppm/K; 6.0 ppm/°F); Pre-wired (TPE-insulated ribbon cable); Bondable | Strain gauge; 3-grid rosette; Constantan (ca 2.0); Standard (up to 200°C); Ferritic steel (10.8 ppm/K; 6.0 ppm/°F); Pre-wired (TPE-insulated ribbon cable); Bondable | Strain gauge; T rosette; Constantan (ca 2.0); Standard (up to 200°C); Ferritic steel (10.8 ppm/K; 6.0 ppm/°F); Pre-wired (TPE-insulated ribbon cable); Bondable | Strain gauge; Shear/torsion; Constantan (ca 2.0); Standard (up to 200°C); Ferritic steel (10.8 ppm/K; 6.0 ppm/°F); Pre-wired (TPE-insulated ribbon cable); Bondable |
| source_temperature_range | Standard (up to 200°C) | Standard (up to 200°C) | Standard (up to 200°C) | Standard (up to 200°C) | Standard (up to 200°C) | Standard (up to 200°C) | Standard (up to 200°C) | Standard (up to 200°C) | Standard (up to 200°C) | Standard (up to 200°C) | Standard (up to 200°C) |
| source_repeatability_basis | No unsupported standalone repeatability is inferred; installed repeatability is verified after bonding and shunt calibration. | No unsupported standalone repeatability is inferred; installed repeatability is verified after bonding and shunt calibration. | No unsupported standalone repeatability is inferred; installed repeatability is verified after bonding and shunt calibration. | No unsupported standalone repeatability is inferred; installed repeatability is verified after bonding and shunt calibration. | No unsupported standalone repeatability is inferred; installed repeatability is verified after bonding and shunt calibration. | No unsupported standalone repeatability is inferred; installed repeatability is verified after bonding and shunt calibration. | No unsupported standalone repeatability is inferred; installed repeatability is verified after bonding and shunt calibration. | No unsupported standalone repeatability is inferred; installed repeatability is verified after bonding and shunt calibration. | No unsupported standalone repeatability is inferred; installed repeatability is verified after bonding and shunt calibration. | No unsupported standalone repeatability is inferred; installed repeatability is verified after bonding and shunt calibration. | No unsupported standalone repeatability is inferred; installed repeatability is verified after bonding and shunt calibration. |
| source_geometry | Linear | Linear | Linear | Linear | Linear | Linear | Linear | 3-grid rosette | 3-grid rosette | T rosette | Shear/torsion |
| gauge_carrier_length | 7 mm | 18 mm | 10.9 mm | 13.9 mm | 13.9 mm | 13.9 mm | 6.6 mm | 9.699999999999999 mm | 13.1 mm | 12 mm | 16 mm |
| Grid length | 1.5 mm | 10 mm | 3 mm | 6 mm | 6 mm | 6 mm | 1.5 mm | 3 mm | 6 mm | 6 mm | 6 mm |
| interface_specification | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown |
| Grid width | 1.2 mm | 5 mm | 2.5 mm | 2.7 mm | 2.8 mm | 2.8 mm | 2 mm | 1.2 mm | 2.8 mm | 6.5 mm | 6 mm |
| Status | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active |