SP8-8kg
From the SP8 series
SP8: sensors and measurement devices by HBK for force.
- Force range
- 0–78.4532 N
Technical specification
Every engineering figure, laid out to scan quickly
| Force range | 0–78.4532 N |
|---|---|
| Interfaces | ethercat |
| interface_specification | RS422 / RS485 |
| quantity_specification | 8 kg rated capacity = 78.4532 N (8 kg mass equivalent at standard gravity); compression |
| ADC sampling rate | 40000 samples/s |
| source_sampling_rate_basis | MX840B maximum per-channel sample rate; sensor mechanics and filter settings can reduce usable bandwidth |
| source_sampling_rate_basis | ClipX fixed internal sampling rate; verify the configured filter and usable output bandwidth |
| Interfaces | ethernet |
| ADC sampling rate | 19200 samples/s |
| Interfaces | io_link |
| interface_specification | Analog 0-10V |
| source_sampling_rate_basis | LCMC measurement-chain update rate is variant- and filter-dependent; confirm it for the ordered chain |
| source_sampling_rate_basis | LCMC digital update rate is variant- and filter-dependent; confirm it for the ordered chain |
| Interfaces | profinet |
| source_sampling_rate_basis | LCMC analog bandwidth is variant- and filter-dependent; confirm it for the ordered chain |
| interface_specification | Digital I/O |
| interface_specification | 4-20mA |
The industries we serve
Get a quote or advice
Tell us what you need and an engineer will come back to you.