Skip to content

Shared technical specifications for the series

Properties every model in the series has. What differs is in the models table below.

Range across models

The span covered by the models of the series together — not the range of each model.

Range across the models of T40B
Torque range -10000–10000 Nm
Maximum rotational speed 12000–24000 rpm
ADC sampling rate 1000–20000 samples/s

Models in the series

One column per model: what differs between the models of the series.

Models of T40B compared by parameter
Parameter T40B eli-m-9f02e1ef337adde226b16645 T40B-100Nm eli-m-3e122588d818cfbd4dfd5cc9 T40B-10kNm eli-m-22d7e244b9d5de592197d1e0 T40B-1kNm eli-m-4476f34d184aa6a887cac651 T40B-200Nm eli-m-c90bcd87e20ed90c8bf89e07 T40B-2kNm eli-m-b6f142fbf9a47882b78ea972 T40B-3kNm eli-m-7ce043c1013b156b34164b3e T40B-500Nm eli-m-2233aaae27f9a8111ea13427 T40B-50Nm eli-m-7ed266d1e74d42fd8e9f17c5 T40B-5kNm eli-m-070771d5e54c69875f5f5cad
Accuracy (% FSO) 0.05 % 0.05 % 0.05 % 0.05 % 0.05 % 0.05 % 0.05 % 0.05 % 0.05 % 0.05 %
quantity_specification Configurable family; exact public ordering-code table not exposed on the current HBK page. ±100 Nm rated torque; rotating installation; maximum 24,000 rpm ±10 kNm rated torque; rotating installation; maximum 12,000 rpm ±1 kNm rated torque; rotating installation; maximum 23,000 rpm ±200 Nm rated torque; rotating installation; maximum 24,000 rpm ±2 kNm rated torque; rotating installation; maximum 18,000 rpm ±3 kNm rated torque; rotating installation; maximum 18,000 rpm ±500 Nm rated torque; rotating installation; maximum 24,000 rpm ±50 Nm rated torque; rotating installation; maximum 24,000 rpm ±5 kNm rated torque; rotating installation; maximum 14,000 rpm
interface_specification Unknown Digital I/O Digital I/O Digital I/O Digital I/O Digital I/O Digital I/O Digital I/O Digital I/O Digital I/O
source_linearity_basis Not specified "Non-linearity including hysteresis, relative to nominal rated sensitivity; piecewise by maximum torque band and frequency/voltage output mode." "Non-linearity including hysteresis, relative to nominal rated sensitivity; piecewise by maximum torque band and frequency/voltage output mode." "Non-linearity including hysteresis, relative to nominal rated sensitivity; piecewise by maximum torque band and frequency/voltage output mode." "Non-linearity including hysteresis, relative to nominal rated sensitivity; piecewise by maximum torque band and frequency/voltage output mode." "Non-linearity including hysteresis, relative to nominal rated sensitivity; piecewise by maximum torque band and frequency/voltage output mode." "Non-linearity including hysteresis, relative to nominal rated sensitivity; piecewise by maximum torque band and frequency/voltage output mode." "Non-linearity including hysteresis, relative to nominal rated sensitivity; piecewise by maximum torque band and frequency/voltage output mode." "Non-linearity including hysteresis, relative to nominal rated sensitivity; piecewise by maximum torque band and frequency/voltage output mode." "Non-linearity including hysteresis, relative to nominal rated sensitivity; piecewise by maximum torque band and frequency/voltage output mode."
source_sampling_rate_basis Not specified TIM-EC bus cycle; transducer bandwidth and selected filters remain limiting factors TIM-EC bus cycle; transducer bandwidth and selected filters remain limiting factors TIM40 bus cycle; transducer bandwidth and selected filters remain limiting factors TIM40 bus cycle; transducer bandwidth and selected filters remain limiting factors TIM-EC bus cycle; transducer bandwidth and selected filters remain limiting factors TIM-EC bus cycle; transducer bandwidth and selected filters remain limiting factors TIM-PN bus cycle; transducer bandwidth and selected filters remain limiting factors TIM-EC bus cycle; transducer bandwidth and selected filters remain limiting factors TIM-PN bus cycle; transducer bandwidth and selected filters remain limiting factors
Torque range Not specified -100–100 Nm -10000–10000 Nm -1000–1000 Nm -200–200 Nm -2000–2000 Nm -3000–3000 Nm -500–500 Nm -50–50 Nm -5000–5000 Nm
Interfaces Not specified profinet ethercat ethernet ethercat profinet profinet ethercat ethercat ethernet
Maximum rotational speed Not specified 24000 rpm 12000 rpm 23000 rpm 24000 rpm 18000 rpm 18000 rpm 24000 rpm 24000 rpm 14000 rpm
ADC sampling rate Not specified 1000 samples/s 1000 samples/s 4000 samples/s 1000 samples/s 4000 samples/s 20000 samples/s 1000 samples/s 4000 samples/s 20000 samples/s
Operating temperature Not specified -20–85 °C -20–85 °C -20–85 °C -20–85 °C -20–85 °C -20–85 °C -20–85 °C -20–85 °C -20–85 °C
source_torque_speed_measurement Not specified True True True True True True True True True
Protection class (DIN EN 60529) Not specified ip54 ip54 ip54 ip54 ip54 ip54 ip54 ip54 ip54
source_repeatability_basis Not specified "Relative standard deviation per DIN 1319, relative to variation of the output signal." "Relative standard deviation per DIN 1319, relative to variation of the output signal." "Relative standard deviation per DIN 1319, relative to variation of the output signal." "Relative standard deviation per DIN 1319, relative to variation of the output signal." "Relative standard deviation per DIN 1319, relative to variation of the output signal." "Relative standard deviation per DIN 1319, relative to variation of the output signal." "Relative standard deviation per DIN 1319, relative to variation of the output signal." "Relative standard deviation per DIN 1319, relative to variation of the output signal." "Relative standard deviation per DIN 1319, relative to variation of the output signal."
Status Active Active Active Active Active Active Active Active Active Active

The industries we serve

Frequently asked questions

Answers to the most common questions about our products and services

No. The family brochure’s 6 kHz at −3 dB describes frequency response. TIM-EC separately specifies a bus rate up to 20 kHz. Evaluate both for the selected system path.

No. TMC is the torque measurement communication interface. The brochure identifies separate TIM modules: TIM-EC for EtherCAT and TIM-PN for PROFINET. Select the corresponding adapter.

The brochure describes a compact torque flange for test benches and process monitoring, with distinct nominal-torque versions. Match rotational speed and parasitic loads as well.

No. The brochure’s maximum of up to 24,000 rpm is explicitly range-dependent. Select speed for the exact capacity and configuration.

The brochure lists the speed system with reference signal and 1024 pulses/revolution as an option. Do not assign it to every order code.

Didn't find the answer you were looking for?

Talk to an expert

More information

Get a quote or advice

Tell us what you need and an engineer will come back to you.

Request a quote for this product
What would you like to ask for?

Email or phone — one of them is enough

Email or phone — one of them is enough

0 of 500 words