T40B Torque
T40B: sensors and measurement devices by HBK for torque.
This series on the HBK site (opens in a new tab)
Shared technical specifications for the series
Properties every model in the series has. What differs is in the models table below.
Range across models
The span covered by the models of the series together — not the range of each model.
| Torque range | -10000–10000 Nm |
|---|---|
| Maximum rotational speed | 12000–24000 rpm |
| ADC sampling rate | 1000–20000 samples/s |
Models in the series
One column per model: what differs between the models of the series.
| Parameter | T40B eli-m-9f02e1ef337adde226b16645 | T40B-100Nm eli-m-3e122588d818cfbd4dfd5cc9 | T40B-10kNm eli-m-22d7e244b9d5de592197d1e0 | T40B-1kNm eli-m-4476f34d184aa6a887cac651 | T40B-200Nm eli-m-c90bcd87e20ed90c8bf89e07 | T40B-2kNm eli-m-b6f142fbf9a47882b78ea972 | T40B-3kNm eli-m-7ce043c1013b156b34164b3e | T40B-500Nm eli-m-2233aaae27f9a8111ea13427 | T40B-50Nm eli-m-7ed266d1e74d42fd8e9f17c5 | T40B-5kNm eli-m-070771d5e54c69875f5f5cad |
|---|---|---|---|---|---|---|---|---|---|---|
| Accuracy (% FSO) | 0.05 % | 0.05 % | 0.05 % | 0.05 % | 0.05 % | 0.05 % | 0.05 % | 0.05 % | 0.05 % | 0.05 % |
| quantity_specification | Configurable family; exact public ordering-code table not exposed on the current HBK page. | ±100 Nm rated torque; rotating installation; maximum 24,000 rpm | ±10 kNm rated torque; rotating installation; maximum 12,000 rpm | ±1 kNm rated torque; rotating installation; maximum 23,000 rpm | ±200 Nm rated torque; rotating installation; maximum 24,000 rpm | ±2 kNm rated torque; rotating installation; maximum 18,000 rpm | ±3 kNm rated torque; rotating installation; maximum 18,000 rpm | ±500 Nm rated torque; rotating installation; maximum 24,000 rpm | ±50 Nm rated torque; rotating installation; maximum 24,000 rpm | ±5 kNm rated torque; rotating installation; maximum 14,000 rpm |
| interface_specification | Unknown | Digital I/O | Digital I/O | Digital I/O | Digital I/O | Digital I/O | Digital I/O | Digital I/O | Digital I/O | Digital I/O |
| source_linearity_basis | Not specified | "Non-linearity including hysteresis, relative to nominal rated sensitivity; piecewise by maximum torque band and frequency/voltage output mode." | "Non-linearity including hysteresis, relative to nominal rated sensitivity; piecewise by maximum torque band and frequency/voltage output mode." | "Non-linearity including hysteresis, relative to nominal rated sensitivity; piecewise by maximum torque band and frequency/voltage output mode." | "Non-linearity including hysteresis, relative to nominal rated sensitivity; piecewise by maximum torque band and frequency/voltage output mode." | "Non-linearity including hysteresis, relative to nominal rated sensitivity; piecewise by maximum torque band and frequency/voltage output mode." | "Non-linearity including hysteresis, relative to nominal rated sensitivity; piecewise by maximum torque band and frequency/voltage output mode." | "Non-linearity including hysteresis, relative to nominal rated sensitivity; piecewise by maximum torque band and frequency/voltage output mode." | "Non-linearity including hysteresis, relative to nominal rated sensitivity; piecewise by maximum torque band and frequency/voltage output mode." | "Non-linearity including hysteresis, relative to nominal rated sensitivity; piecewise by maximum torque band and frequency/voltage output mode." |
| source_sampling_rate_basis | Not specified | TIM-EC bus cycle; transducer bandwidth and selected filters remain limiting factors | TIM-EC bus cycle; transducer bandwidth and selected filters remain limiting factors | TIM40 bus cycle; transducer bandwidth and selected filters remain limiting factors | TIM40 bus cycle; transducer bandwidth and selected filters remain limiting factors | TIM-EC bus cycle; transducer bandwidth and selected filters remain limiting factors | TIM-EC bus cycle; transducer bandwidth and selected filters remain limiting factors | TIM-PN bus cycle; transducer bandwidth and selected filters remain limiting factors | TIM-EC bus cycle; transducer bandwidth and selected filters remain limiting factors | TIM-PN bus cycle; transducer bandwidth and selected filters remain limiting factors |
| Torque range | Not specified | -100–100 Nm | -10000–10000 Nm | -1000–1000 Nm | -200–200 Nm | -2000–2000 Nm | -3000–3000 Nm | -500–500 Nm | -50–50 Nm | -5000–5000 Nm |
| Interfaces | Not specified | profinet | ethercat | ethernet | ethercat | profinet | profinet | ethercat | ethercat | ethernet |
| Maximum rotational speed | Not specified | 24000 rpm | 12000 rpm | 23000 rpm | 24000 rpm | 18000 rpm | 18000 rpm | 24000 rpm | 24000 rpm | 14000 rpm |
| ADC sampling rate | Not specified | 1000 samples/s | 1000 samples/s | 4000 samples/s | 1000 samples/s | 4000 samples/s | 20000 samples/s | 1000 samples/s | 4000 samples/s | 20000 samples/s |
| Operating temperature | Not specified | -20–85 °C | -20–85 °C | -20–85 °C | -20–85 °C | -20–85 °C | -20–85 °C | -20–85 °C | -20–85 °C | -20–85 °C |
| source_torque_speed_measurement | Not specified | True | True | True | True | True | True | True | True | True |
| Protection class (DIN EN 60529) | Not specified | ip54 | ip54 | ip54 | ip54 | ip54 | ip54 | ip54 | ip54 | ip54 |
| source_repeatability_basis | Not specified | "Relative standard deviation per DIN 1319, relative to variation of the output signal." | "Relative standard deviation per DIN 1319, relative to variation of the output signal." | "Relative standard deviation per DIN 1319, relative to variation of the output signal." | "Relative standard deviation per DIN 1319, relative to variation of the output signal." | "Relative standard deviation per DIN 1319, relative to variation of the output signal." | "Relative standard deviation per DIN 1319, relative to variation of the output signal." | "Relative standard deviation per DIN 1319, relative to variation of the output signal." | "Relative standard deviation per DIN 1319, relative to variation of the output signal." | "Relative standard deviation per DIN 1319, relative to variation of the output signal." |
| Status | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active |
The industries we serve
Frequently asked questions
Answers to the most common questions about our products and services
No. The family brochure’s 6 kHz at −3 dB describes frequency response. TIM-EC separately specifies a bus rate up to 20 kHz. Evaluate both for the selected system path.
No. TMC is the torque measurement communication interface. The brochure identifies separate TIM modules: TIM-EC for EtherCAT and TIM-PN for PROFINET. Select the corresponding adapter.
The brochure describes a compact torque flange for test benches and process monitoring, with distinct nominal-torque versions. Match rotational speed and parasitic loads as well.
No. The brochure’s maximum of up to 24,000 rpm is explicitly range-dependent. Select speed for the exact capacity and configuration.
The brochure lists the speed system with reference signal and 1024 pulses/revolution as an option. Do not assign it to every order code.
Get a quote or advice