T40FH Torque
T40FH: sensors and measurement devices by HBK for torque.
This series on the HBK site (opens in a new tab)
Shared technical specifications for the series
Properties every model in the series has. What differs is in the models table below.
Range across models
The span covered by the models of the series together — not the range of each model.
| Torque range | -300000–300000 Nm |
|---|---|
| ADC sampling rate | 1000–20000 samples/s |
| Maximum rotational speed | 2000–3000 rpm |
Models in the series
One column per model: what differs between the models of the series.
| Parameter | T40FH eli-m-07e2b6487691ee09dbda5924 | T40FH-100kNm eli-m-d274ff70f8bc55942e0e8d6e | T40FH-125kNm eli-m-b1473b34773bb977003a9e21 | T40FH-150kNm eli-m-dd699e8f1420b1b90d9372f8 | T40FH-200kNm eli-m-c1e43c5968aa0113d4f24aea | T40FH-250kNm eli-m-238c39cbe32bb6d9775414c4 | T40FH-300kNm eli-m-3149e108ba7b0adb330ab233 |
|---|---|---|---|---|---|---|---|
| interface_specification | Unknown | Digital I/O | Digital I/O | Digital I/O | Digital I/O | Digital I/O | Digital I/O |
| quantity_specification | Configurable family; exact public ordering-code table not exposed on the current HBK page. | ±100 kNm rated torque; rotating or static / reaction installation; maximum 3,000 rpm | ±125 kNm rated torque; rotating or static / reaction installation; maximum 3,000 rpm | ±150 kNm rated torque; rotating or static / reaction installation; maximum 3,000 rpm | ±200 kNm rated torque; rotating or static / reaction installation; maximum 2,000 rpm | ±250 kNm rated torque; rotating or static / reaction installation; maximum 2,000 rpm | ±300 kNm rated torque; rotating or static / reaction installation; maximum 2,000 rpm |
| Force range | 100000–300000 N | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified |
| Force range | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified |
| Protection class (DIN EN 60529) | Not specified | ip54 | ip54 | ip54 | ip54 | ip54 | ip54 |
| source_torque_speed_measurement | Not specified | True | True | True | True | True | True |
| Torque range | Not specified | -100000–100000 Nm | -125000–125000 Nm | -150000–150000 Nm | -200000–200000 Nm | -250000–250000 Nm | -300000–300000 Nm |
| source_sampling_rate_basis | Not specified | TIM-PN bus cycle; transducer bandwidth and selected filters remain limiting factors | TIM40 bus cycle; transducer bandwidth and selected filters remain limiting factors | TIM40 bus cycle; transducer bandwidth and selected filters remain limiting factors | TIM40 bus cycle; transducer bandwidth and selected filters remain limiting factors | TIM-PN bus cycle; transducer bandwidth and selected filters remain limiting factors | TIM40 bus cycle; transducer bandwidth and selected filters remain limiting factors |
| ADC sampling rate | Not specified | 1000 samples/s | 1000 samples/s | 4000 samples/s | 20000 samples/s | 20000 samples/s | 20000 samples/s |
| Interfaces | Not specified | ethernet | ethercat | ethernet | ethernet | ethercat | ethercat |
| source_linearity_basis | Not specified | "Non-linearity including hysteresis, with output mode and maximum-torque band preserved in precisionData." | "Non-linearity including hysteresis, with output mode and maximum-torque band preserved in precisionData." | "Non-linearity including hysteresis, with output mode and maximum-torque band preserved in precisionData." | "Non-linearity including hysteresis, with output mode and maximum-torque band preserved in precisionData." | "Non-linearity including hysteresis, with output mode and maximum-torque band preserved in precisionData." | "Non-linearity including hysteresis, with output mode and maximum-torque band preserved in precisionData." |
| Maximum rotational speed | Not specified | 3000 rpm | 3000 rpm | 3000 rpm | 2000 rpm | 2000 rpm | 2000 rpm |
| source_repeatability_basis | Not specified | "Relative standard deviation of repeatability/reproducibility per DIN 1319, relative to output-signal variation; mode-specific values retained in precisionData." | "Relative standard deviation of repeatability/reproducibility per DIN 1319, relative to output-signal variation; mode-specific values retained in precisionData." | "Relative standard deviation of repeatability/reproducibility per DIN 1319, relative to output-signal variation; mode-specific values retained in precisionData." | "Relative standard deviation of repeatability/reproducibility per DIN 1319, relative to output-signal variation; mode-specific values retained in precisionData." | "Relative standard deviation of repeatability/reproducibility per DIN 1319, relative to output-signal variation; mode-specific values retained in precisionData." | "Relative standard deviation of repeatability/reproducibility per DIN 1319, relative to output-signal variation; mode-specific values retained in precisionData." |
| Operating temperature | Not specified | -20–85 °C | -20–85 °C | -20–85 °C | -20–85 °C | -20–85 °C | -20–85 °C |
| Status | Active | Active | Active | Active | Active | Active | Active |
The industries we serve
Frequently asked questions
Answers to the most common questions about our products and services
No. The family brochure’s 6 kHz at −3 dB describes frequency response. TIM-EC separately specifies a bus rate up to 20 kHz. Evaluate both for the selected system path.
No. TMC is the torque measurement communication interface. The brochure identifies separate TIM modules: TIM-EC for EtherCAT and TIM-PN for PROFINET. Select the corresponding adapter.
It lists nominal capacities of 100–300 kN·m in a short flange design. Match the configuration to load and system geometry.
The brochure specifies up to 3000 rpm with torque-range dependence. Compatibility requires the speed rating for the selected capacity.
No. It is listed as an option with a reference signal and 72 or 86 pulses/revolution. Select the option and acquisition settings for the configuration.
Get a quote or advice
Tell us what you need and an engineer will come back to you.