Skip to content

T40FH Torque

T40FH: sensors and measurement devices by HBK for torque.

This series on the HBK site (opens in a new tab)

Shared technical specifications for the series

Properties every model in the series has. What differs is in the models table below.

Range across models

The span covered by the models of the series together — not the range of each model.

Range across the models of T40FH
Torque range -300000–300000 Nm
ADC sampling rate 1000–20000 samples/s
Maximum rotational speed 2000–3000 rpm

Models in the series

One column per model: what differs between the models of the series.

Models of T40FH compared by parameter
Parameter T40FH eli-m-07e2b6487691ee09dbda5924 T40FH-100kNm eli-m-d274ff70f8bc55942e0e8d6e T40FH-125kNm eli-m-b1473b34773bb977003a9e21 T40FH-150kNm eli-m-dd699e8f1420b1b90d9372f8 T40FH-200kNm eli-m-c1e43c5968aa0113d4f24aea T40FH-250kNm eli-m-238c39cbe32bb6d9775414c4 T40FH-300kNm eli-m-3149e108ba7b0adb330ab233
interface_specification Unknown Digital I/O Digital I/O Digital I/O Digital I/O Digital I/O Digital I/O
quantity_specification Configurable family; exact public ordering-code table not exposed on the current HBK page. ±100 kNm rated torque; rotating or static / reaction installation; maximum 3,000 rpm ±125 kNm rated torque; rotating or static / reaction installation; maximum 3,000 rpm ±150 kNm rated torque; rotating or static / reaction installation; maximum 3,000 rpm ±200 kNm rated torque; rotating or static / reaction installation; maximum 2,000 rpm ±250 kNm rated torque; rotating or static / reaction installation; maximum 2,000 rpm ±300 kNm rated torque; rotating or static / reaction installation; maximum 2,000 rpm
Force range 100000–300000 N Not specified Not specified Not specified Not specified Not specified Not specified
Force range Not specified Not specified Not specified Not specified Not specified Not specified Not specified
Protection class (DIN EN 60529) Not specified ip54 ip54 ip54 ip54 ip54 ip54
source_torque_speed_measurement Not specified True True True True True True
Torque range Not specified -100000–100000 Nm -125000–125000 Nm -150000–150000 Nm -200000–200000 Nm -250000–250000 Nm -300000–300000 Nm
source_sampling_rate_basis Not specified TIM-PN bus cycle; transducer bandwidth and selected filters remain limiting factors TIM40 bus cycle; transducer bandwidth and selected filters remain limiting factors TIM40 bus cycle; transducer bandwidth and selected filters remain limiting factors TIM40 bus cycle; transducer bandwidth and selected filters remain limiting factors TIM-PN bus cycle; transducer bandwidth and selected filters remain limiting factors TIM40 bus cycle; transducer bandwidth and selected filters remain limiting factors
ADC sampling rate Not specified 1000 samples/s 1000 samples/s 4000 samples/s 20000 samples/s 20000 samples/s 20000 samples/s
Interfaces Not specified ethernet ethercat ethernet ethernet ethercat ethercat
source_linearity_basis Not specified "Non-linearity including hysteresis, with output mode and maximum-torque band preserved in precisionData." "Non-linearity including hysteresis, with output mode and maximum-torque band preserved in precisionData." "Non-linearity including hysteresis, with output mode and maximum-torque band preserved in precisionData." "Non-linearity including hysteresis, with output mode and maximum-torque band preserved in precisionData." "Non-linearity including hysteresis, with output mode and maximum-torque band preserved in precisionData." "Non-linearity including hysteresis, with output mode and maximum-torque band preserved in precisionData."
Maximum rotational speed Not specified 3000 rpm 3000 rpm 3000 rpm 2000 rpm 2000 rpm 2000 rpm
source_repeatability_basis Not specified "Relative standard deviation of repeatability/reproducibility per DIN 1319, relative to output-signal variation; mode-specific values retained in precisionData." "Relative standard deviation of repeatability/reproducibility per DIN 1319, relative to output-signal variation; mode-specific values retained in precisionData." "Relative standard deviation of repeatability/reproducibility per DIN 1319, relative to output-signal variation; mode-specific values retained in precisionData." "Relative standard deviation of repeatability/reproducibility per DIN 1319, relative to output-signal variation; mode-specific values retained in precisionData." "Relative standard deviation of repeatability/reproducibility per DIN 1319, relative to output-signal variation; mode-specific values retained in precisionData." "Relative standard deviation of repeatability/reproducibility per DIN 1319, relative to output-signal variation; mode-specific values retained in precisionData."
Operating temperature Not specified -20–85 °C -20–85 °C -20–85 °C -20–85 °C -20–85 °C -20–85 °C
Status Active Active Active Active Active Active Active

The industries we serve

Frequently asked questions

Answers to the most common questions about our products and services

No. The family brochure’s 6 kHz at −3 dB describes frequency response. TIM-EC separately specifies a bus rate up to 20 kHz. Evaluate both for the selected system path.

No. TMC is the torque measurement communication interface. The brochure identifies separate TIM modules: TIM-EC for EtherCAT and TIM-PN for PROFINET. Select the corresponding adapter.

It lists nominal capacities of 100–300 kN·m in a short flange design. Match the configuration to load and system geometry.

The brochure specifies up to 3000 rpm with torque-range dependence. Compatibility requires the speed rating for the selected capacity.

No. It is listed as an option with a reference signal and 72 or 86 pulses/revolution. Select the option and acquisition settings for the configuration.

Didn't find the answer you were looking for?