Skip to content

T40FM Torque

T40FM: sensors and measurement devices by HBK for torque.

This series on the HBK site (opens in a new tab)

Shared technical specifications for the series

Properties every model in the series has. What differs is in the models table below.

Range across models

The span covered by the models of the series together — not the range of each model.

Range across the models of T40FM
Torque range -80000–80000 Nm
Maximum rotational speed 4500–8000 rpm
ADC sampling rate 1000–20000 samples/s

Models in the series

One column per model: what differs between the models of the series.

Models of T40FM compared by parameter
Parameter T40FM eli-m-1806970f8e13268e8ceb947c T40FM-15kNm eli-m-157acee387f8764478d1f98f T40FM-20kNm eli-m-9e0cf5a3dbd66f32d0bff219 T40FM-25kNm eli-m-29906c63d6f6744422eede02 T40FM-30kNm eli-m-8f841996993d8daa6c655bf8 T40FM-40kNm eli-m-6feaa66f788079b140e889f6 T40FM-50kNm eli-m-671ebfcf3382615c3d2ada2b T40FM-60kNm eli-m-ad23082a855163344b93f997 T40FM-70kNm eli-m-271eaacde821f8d36851fb95 T40FM-80kNm eli-m-31545c950a65f13c7450c2b5
interface_specification Unknown Digital I/O Digital I/O Digital I/O Digital I/O Digital I/O Digital I/O Digital I/O Digital I/O Digital I/O
quantity_specification Configurable family; exact public ordering-code table not exposed on the current HBK page. ±15 kNm rated torque; rotating installation; maximum 8,000 rpm ±20 kNm rated torque; rotating installation; maximum 8,000 rpm ±25 kNm rated torque; rotating installation; maximum 8,000 rpm ±30 kNm rated torque; rotating installation; maximum 6,000 rpm ±40 kNm rated torque; rotating installation; maximum 6,000 rpm ±50 kNm rated torque; rotating installation; maximum 6,000 rpm ±60 kNm rated torque; rotating installation; maximum 4,500 rpm ±70 kNm rated torque; rotating installation; maximum 4,500 rpm ±80 kNm rated torque; rotating installation; maximum 4,500 rpm
Force range 15000–80000 N Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified
Force range Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified
source_repeatability_basis Not specified "Relative standard deviation of repeatability/reproducibility per DIN 1319, relative to output-signal variation; mode-specific values retained in precisionData." "Relative standard deviation of repeatability/reproducibility per DIN 1319, relative to output-signal variation; mode-specific values retained in precisionData." "Relative standard deviation of repeatability/reproducibility per DIN 1319, relative to output-signal variation; mode-specific values retained in precisionData." "Relative standard deviation of repeatability/reproducibility per DIN 1319, relative to output-signal variation; mode-specific values retained in precisionData." "Relative standard deviation of repeatability/reproducibility per DIN 1319, relative to output-signal variation; mode-specific values retained in precisionData." "Relative standard deviation of repeatability/reproducibility per DIN 1319, relative to output-signal variation; mode-specific values retained in precisionData." "Relative standard deviation of repeatability/reproducibility per DIN 1319, relative to output-signal variation; mode-specific values retained in precisionData." "Relative standard deviation of repeatability/reproducibility per DIN 1319, relative to output-signal variation; mode-specific values retained in precisionData." "Relative standard deviation of repeatability/reproducibility per DIN 1319, relative to output-signal variation; mode-specific values retained in precisionData."
Torque range Not specified -15000–15000 Nm -20000–20000 Nm -25000–25000 Nm -30000–30000 Nm -40000–40000 Nm -50000–50000 Nm -60000–60000 Nm -70000–70000 Nm -80000–80000 Nm
Maximum rotational speed Not specified 8000 rpm 8000 rpm 8000 rpm 6000 rpm 6000 rpm 6000 rpm 4500 rpm 4500 rpm 4500 rpm
source_linearity_basis Not specified "Non-linearity including hysteresis, with output mode and maximum-torque band preserved in precisionData." "Non-linearity including hysteresis, with output mode and maximum-torque band preserved in precisionData." "Non-linearity including hysteresis, with output mode and maximum-torque band preserved in precisionData." "Non-linearity including hysteresis, with output mode and maximum-torque band preserved in precisionData." "Non-linearity including hysteresis, with output mode and maximum-torque band preserved in precisionData." "Non-linearity including hysteresis, with output mode and maximum-torque band preserved in precisionData." "Non-linearity including hysteresis, with output mode and maximum-torque band preserved in precisionData." "Non-linearity including hysteresis, with output mode and maximum-torque band preserved in precisionData." "Non-linearity including hysteresis, with output mode and maximum-torque band preserved in precisionData."
source_torque_speed_measurement Not specified True True True True True True True True True
Operating temperature Not specified -20–85 °C -20–85 °C -20–85 °C -20–85 °C -20–85 °C -20–85 °C -20–85 °C -20–85 °C -20–85 °C
source_sampling_rate_basis Not specified TIM40 bus cycle; transducer bandwidth and selected filters remain limiting factors TIM40 bus cycle; transducer bandwidth and selected filters remain limiting factors TIM40 bus cycle; transducer bandwidth and selected filters remain limiting factors TIM-EC bus cycle; transducer bandwidth and selected filters remain limiting factors TIM-EC bus cycle; transducer bandwidth and selected filters remain limiting factors TIM-PN bus cycle; transducer bandwidth and selected filters remain limiting factors TIM-EC bus cycle; transducer bandwidth and selected filters remain limiting factors TIM-PN bus cycle; transducer bandwidth and selected filters remain limiting factors TIM40 bus cycle; transducer bandwidth and selected filters remain limiting factors
Interfaces Not specified ethercat profinet ethercat ethernet ethernet ethercat ethercat profinet ethernet
ADC sampling rate Not specified 4000 samples/s 1000 samples/s 20000 samples/s 20000 samples/s 4000 samples/s 20000 samples/s 20000 samples/s 4000 samples/s 4000 samples/s
Protection class (DIN EN 60529) Not specified ip54 ip54 ip54 ip54 ip54 ip54 ip54 ip54 ip54
Status Active Active Active Active Active Active Active Active Active Active

The industries we serve

Frequently asked questions

Answers to the most common questions about our products and services

No. The family brochure’s 6 kHz at −3 dB describes frequency response. TIM-EC separately specifies a bus rate up to 20 kHz. Evaluate both for the selected system path.

No. TMC is the torque measurement communication interface. The brochure identifies separate TIM modules: TIM-EC for EtherCAT and TIM-PN for PROFINET. Select the corresponding adapter.

It lists 15–80 kN·m nominal-capacity versions in a short flange design. These are separate models requiring the corresponding connection geometry.

No. Up to 8000 rpm is marked as torque-range-dependent. Do not assign it to every capacity without the model table.

No. A speed/reference system with 1024 pulses/revolution is listed as an option. Select it when the application also needs speed or power calculation.

Didn't find the answer you were looking for?

Talk to an expert

More information

Get a quote or advice

Tell us what you need and an engineer will come back to you.

Request a quote for this product
What would you like to ask for?

Email or phone — one of them is enough

Email or phone — one of them is enough

0 of 500 words