T40HS Torque
T40HS: sensors and measurement devices by HBK for torque.
This series on the HBK site (opens in a new tab)
Shared technical specifications for the series
Properties every model in the series has. What differs is in the models table below.
Range across models
The span covered by the models of the series together — not the range of each model.
| Torque range | -3000–3000 Nm |
|---|---|
| ADC sampling rate | 1000–4000 samples/s |
Models in the series
One column per model: what differs between the models of the series.
| Parameter | T40HS eli-m-b082c6d4f78a1ed118925b33 | T40HS-100Nm eli-m-597b1d21900b54ef371b0d43 | T40HS-3kNm eli-m-df68967b6889aee800d5ca5f |
|---|---|---|---|
| quantity_specification | Configurable family; exact public ordering-code table not exposed on the current HBK page. | ±100 Nm rated torque; rotating installation; maximum 45,000 rpm | ±3 kNm rated torque; rotating installation; maximum 45,000 rpm |
| interface_specification | Unknown | Digital I/O | Digital I/O |
| Torque range | Not specified | -100–100 Nm | -3000–3000 Nm |
| Interfaces | Not specified | profinet | profinet |
| source_torque_speed_measurement | Not specified | True | True |
| Maximum rotational speed | Not specified | 45000 rpm | 45000 rpm |
| source_sampling_rate_basis | Not specified | TIM40 bus cycle; transducer bandwidth and selected filters remain limiting factors | TIM-EC bus cycle; transducer bandwidth and selected filters remain limiting factors |
| ADC sampling rate | Not specified | 1000 samples/s | 4000 samples/s |
| Status | Active | Active | Active |
The industries we serve
Frequently asked questions
Answers to the most common questions about our products and services
No. The family brochure’s 6 kHz at −3 dB describes frequency response. TIM-EC separately specifies a bus rate up to 20 kHz. Evaluate both for the selected system path.
No. TMC is the torque measurement communication interface. The brochure identifies separate TIM modules: TIM-EC for EtherCAT and TIM-PN for PROFINET. Select the corresponding adapter.
The brochure describes lightweight titanium construction with low inertia for high-speed torque measurement. System suitability also depends on capacity and mechanical connection.
No. The brochure specifies up to 45,000 rpm depending on range. Use the speed rating for the exact torque version.
No. The brochure separately lists nonlinearity including hysteresis and relative standard deviation of repeatability. Preserve each definition’s reference basis.
Get a quote or advice
Tell us what you need and an engineer will come back to you.