Skip to content

thermoMETER SE

thermoMETER SE: sensors and measurement devices by Micro-Epsilon for sensors.

Visit the Micro-Epsilon site (opens in a new tab)

Shared technical specifications for the series

Properties every model in the series has. What differs is in the models table below.

Range across models

The span covered by the models of the series together — not the range of each model.

Range across the models of thermoMETER SE
Storage temperature -40–85 °C
Operating temperature -20–80 °C
Protection class (DIN EN 60529) ip65
Cable length 0.5–15 m
Temperature measuring range -40–1100 °C
Current consumption 4–20 mA

Models in the series

One column per model: what differs between the models of the series.

Models of thermoMETER SE compared by parameter
Parameter SE-SF15-S0.5-C0.5-I eli-m-7ceaffc2f03f0ac45925d74b SE-SF15-S0.5-C0.5-U eli-m-71c39da614a8d111057bd302 SE-SF15-S15-C3-I eli-m-9c88430a4522ff22c63adc6f SE-SF15-S15-C3-U eli-m-158c3dc1191b4b2da21fdd08 SE-SF15-S3-C0.5-I eli-m-cca5293321cc7fff61816fb8 SE-SF15-S3-C0.5-U eli-m-3ef3b3b50d540f0b6d909062 SE-SF15-S3-C3-U eli-m-700933c1804ef79465ed038b SE-SF15-S6-C3-I eli-m-57593686c0d92c7edb46c7cb SE-SF15-S6-C3-U eli-m-d13fcac1fdc7e30ad9444c85
Storage temperature -40–85 °C -40–85 °C -40–85 °C -40–85 °C -40–85 °C -40–85 °C -40–85 °C -40–85 °C -40–85 °C
Operating temperature -20–120 °C -20–120 °C -20–120 °C -20–120 °C -20–120 °C -20–120 °C -20–120 °C -20–120 °C -20–120 °C
Protection class (DIN EN 60529) ip65 ip65 ip65 ip65 ip65 ip65 ip65 ip65 ip65
Response time 0.02 s 0.02 s 0.02 s 0.02 s 0.02 s 0.02 s 0.02 s 0.02 s 0.02 s
Cable length 0.5 m 0.5 m 15 m 15 m 0.5 m 3 m 3 m 6 m 3 m
Weight 0.02 kg 0.02 kg 0.02 kg 0.02 kg 0.02 kg 0.02 kg 0.02 kg 0.02 kg 0.02 kg
Temperature accuracy 1 K 1 K 1 K 1 K 1 K 1 K 1 K 1 K 1 K
Temperature measuring range -40–600 °C -40–600 °C -40–1100 °C -40–1100 °C -40–1100 °C -40–1100 °C -40–1100 °C -40–1100 °C -40–600 °C
Spectral range 8000–14000 nm 8000–14000 nm 8000–14000 nm 8000–14000 nm 8000–14000 nm 8000–14000 nm 8000–14000 nm 8000–14000 nm 8000–14000 nm
interface_specification 4-20mA Analog 0-10V 4-20mA Analog 0-10V 4-20mA Analog 0-10V Digital I/O 4-20mA Analog 0-10V
Emissivity 0.1–1.1 0.1–1.1 0.1–1.1 0.1–1.1 0.1–1.1 0.1–1.1 0.1–1.1 0.1–1.1 0.1–1.1
Current consumption 20 mA 4 mA 20 mA 4 mA 20 mA 4 mA 4 mA 20 mA 4 mA
temperature_repeatability_reading 0.5 % 0.5 % 0.5 % 0.5 % 0.5 % 0.5 % 0.5 % 0.5 % 0.5 %
source_thermal_optical_resolution_ratio 15:1 15:1 15:1 15:1 15:1 15:1 15:1 15:1 15:1
Temperature accuracy (% of reading) 1 % 1 % 1 % 1 % 1 % 1 % 1 % 1 % 1 %
Supply voltage 5–30 V 5–30 V 5–30 V 5–30 V 5–30 V 5–30 V 5–30 V 5–30 V 5–30 V
Transmittance 0.1–1.1 0.1–1.1 0.1–1.1 0.1–1.1 0.1–1.1 0.1–1.1 0.1–1.1 0.1–1.1 0.1–1.1
Temperature repeatability 0.5 K 0.5 K 0.5 K 0.5 K 0.5 K 0.5 K 0.5 K 0.5 K 0.5 K
NETD 50 mK 50 mK 50 mK 50 mK 50 mK 50 mK 50 mK 50 mK 50 mK
Humidity 10–95 %RH 10–95 %RH 10–95 %RH 10–95 %RH 10–95 %RH 10–95 %RH 10–95 %RH 10–95 %RH 10–95 %RH
ADC sampling rate 50 samples/s 50 samples/s 50 samples/s 50 samples/s 50 samples/s 50 samples/s 50 samples/s 50 samples/s 50 samples/s
Interfaces Not specified usb Not specified usb Not specified usb usb Not specified usb
source_sampling_rate_basis Not specified Not specified Not specified Not specified Not specified Not specified 20 ms 0-90% response time (50 Hz equivalent) Not specified Not specified
quantity_specification Not specified Not specified Not specified Not specified Not specified Not specified -40 to +600 C standard, optional extension to 1100 C; 15:1 optics; ±0.5% or ±0.5 C repeatability; 50 mK NETD. Not specified Not specified
source_linearity_basis Not specified Not specified Not specified Not specified Not specified Not specified Micro-Epsilon specifies system accuracy, repeatability and NETD; a separate linearity error is not published. Not specified Not specified
Status Active Active Active Active Active Active Active Active Active
Datasheet PDF — SE-SF15-S0.5-C0.5-I (opens in a new tab) PDF — SE-SF15-S0.5-C0.5-U (opens in a new tab) PDF — SE-SF15-S15-C3-I (opens in a new tab) PDF — SE-SF15-S15-C3-U (opens in a new tab) PDF — SE-SF15-S3-C0.5-I (opens in a new tab) PDF — SE-SF15-S3-C0.5-U (opens in a new tab) PDF — SE-SF15-S3-C3-U (opens in a new tab) PDF — SE-SF15-S6-C3-I (opens in a new tab) PDF — SE-SF15-S6-C3-U (opens in a new tab)

The industries we serve

Frequently asked questions

Answers to the most common questions about our products and services

Its miniature controller is integrated into the connection cable, keeping the sensor head compact. Head and controller are permanently connected but physically separated.

It supports parallel digital and analog operation. The preconfigured current or voltage output can be changed through software.

No. It is the upper target-temperature measurement limit. The page specifies sensor-head ambient temperatures up to 120°C without cooling. Check the cable-controller limits separately.

The page specifies 20 ms. This is temperature-response time; its reciprocal must not be presented as sampling frequency without an explicit definition.

Sensor, controller and cable form a permanently connected, factory-calibrated and preconfigured unit. sensorTOOL provides settings when application-specific changes are needed.

Didn't find the answer you were looking for?

Talk to an expert

More information

Get a quote or advice

Tell us what you need and an engineer will come back to you.

Request a quote for this product
What would you like to ask for?

Email or phone — one of them is enough

Email or phone — one of them is enough

0 of 500 words