Skip to content

K-U10F · 50 kN

From the U10F series

U10F: sensors and measurement devices by HBK for force.

Capacity and selected options are specific to this record. Remaining options: HBK-K-U10F-v1

Download the datasheet (opens in a new tab) This series on the HBK site (opens in a new tab)

Technical specification

Every engineering figure, laid out to scan quickly

Technical specification for K-U10F · 50 kN
Nominal force capacity 50000 N
Ordering options and constraints K-U10F — capacity: 11.2 klbf, 28.1 klbf, 56.2 klbf, 112 klbf, 281 klbf; output_signal: mV/V (passive strain gauge), IO-Link; height_without_accessories: 1.75 in, 2.5 in, 3.5 in, 5 in; diameter_without_cable_or_plug: 15.3543 in, 6.059043 in, 7.999984 in, 10.98423 in; constraints: []
Selected configuration options 50 kN nominal force capacity
Request a quote for this product

Compatible accessories

Cables

  • K-CAB-F-B eli-m-77598bb679b1cefd06e0eb15 Only for source configuration configuration-1a23b6e5c3190fb98cd41f04: K-U10F · 1.25 MN configuration; selected configuration must be matched before display.; Only for the listed passive SG sensor socket; fixed-cable K/V and VAIO/4-pin IO-Link are excluded. Select the amplifier end and validate carrier-frequency precision, EMC and calibration with the cable length.; 0131: static/dynamic bend radius 22/50 mm, -50…80 °C, 280 Ω/km; high-precision use may require low carrier frequency and stable temperature. 0157: 37/75 mm, -50…85 °C, 78 Ω/km. 139B: 75 mm static, no drag chain; -30…70 °C stationary / -5…50 °C moving; incompatible with P/M ends.; IP protection depends on the actual sensor socket, seal and connector locking; a generic connector IP rating is not the assembled sensor IP rating.
  • K-CAB-F-L eli-m-da3a2435c758af1a6a732a76 Only for source configuration configuration-1a23b6e5c3190fb98cd41f04: K-U10F · 1.25 MN configuration; selected configuration must be matched before display.; Only for the listed passive SG sensor socket; fixed-cable K/V and VAIO/4-pin IO-Link are excluded. Select the amplifier end and validate carrier-frequency precision, EMC and calibration with the cable length.; 0131: static/dynamic bend radius 22/50 mm, -50…80 °C, 280 Ω/km; high-precision use may require low carrier frequency and stable temperature. 0157: 37/75 mm, -50…85 °C, 78 Ω/km. 139B: 75 mm static, no drag chain; -30…70 °C stationary / -5…50 °C moving; incompatible with P/M ends.; IP protection depends on the actual sensor socket, seal and connector locking; a generic connector IP rating is not the assembled sensor IP rating.

The industries we serve

Get a quote or advice

Tell us what you need and an engineer will come back to you.

Request a quote for this product
What would you like to ask for?

Email or phone — one of them is enough

Email or phone — one of them is enough

0 of 500 words