Z30A-10000N
From the Z30A series
Z30A: sensors and measurement devices by HBK for force.
- Force range
- -10000–10000 N
Technical specification
Every engineering figure, laid out to scan quickly
| Force range | -10000–10000 N |
|---|---|
| Accuracy (% FSO) | 0.02 % |
| Interfaces | ethernet |
| interface_specification | RS422 / RS485 |
| quantity_specification | 10000 N rated capacity = 10 kN (1.0197 t mass equivalent at standard gravity); compression and tension |
| ADC sampling rate | 40000 samples/s |
| source_sampling_rate_basis | ClipX fixed internal sampling rate; verify the configured filter and usable output bandwidth |
| source_sampling_rate_basis | DMP41 selectable result rate, intended for reference and calibration measurements |
| ADC sampling rate | 19200 samples/s |
| ADC sampling rate | 450 samples/s |
| Interfaces | ethercat |
| source_sampling_rate_basis | MX840B maximum per-channel sample rate; sensor mechanics and filter settings can reduce usable bandwidth |
| Interfaces | profinet |
| interface_specification | Analog 0-10V |
| interface_specification | Digital I/O |