Z30A Force
Z30A: sensors and measurement devices by HBK for force.
This series on the HBK site (opens in a new tab)
Shared technical specifications for the series
Properties every model in the series has. What differs is in the models table below.
Range across models
The span covered by the models of the series together — not the range of each model.
| Force range | -10000–10000 N |
|---|---|
| ADC sampling rate | 450–40000 samples/s |
Models in the series
One column per model: what differs between the models of the series.
| Parameter | 1-Z30A/1000N eli-m-ec61b3cbe81bc26584b35456 | 1-Z30A/100N eli-m-cb4359319a918302f1698763 | 1-Z30A/10KN eli-m-9a9acebcae1150c4e125fc19 | 1-Z30A/200N eli-m-5fa3c9a627bbf00f40d5989a | 1-Z30A/2KN eli-m-ffcb50c3231b75163bed8ace | 1-Z30A/500N eli-m-8c77e0d14a88fb8adfaab905 | 1-Z30A/50N eli-m-17d70787b3ac989c31185766 | 1-Z30A/5KN eli-m-f198222e7c2362e5f617987e | Z30A-10000N eli-m-9da873727fd2a2b8fc307fe6 | Z30A-1000N eli-m-a275963b4eb4200b4b8249c7 | Z30A-100N eli-m-c7cc4dd62f524da2f5ea8eba | Z30A-2000N eli-m-2753b87eb14832e7b5e6548c | Z30A-200N eli-m-d16a41843ad43d3cb74a7a60 | Z30A-5000N eli-m-28507810271a157370c41654 | Z30A-500N eli-m-8b57e25bb74f9d34bf388fc0 | Z30A-50N eli-m-886b737b96477d1058665bc5 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Force range | 0–1000 N | 0–100 N | 0–10000 N | 0–200 N | 0–2000 N | 0–500 N | 0–50 N | 0–5000 N | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified |
| interface_specification | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown | RS422 / RS485 | Analog 0-10V | RS422 / RS485 | Digital I/O | Analog 0-10V | Digital I/O | RS422 / RS485 | Analog 0-10V |
| quantity_specification | Maximum capacity (nominal load): 225 lbf | Maximum capacity (nominal load): 22.5 lbf | Maximum capacity (nominal load): 2.25 klbf | Maximum capacity (nominal load): 45 lbf | Maximum capacity (nominal load): 450 lbf | Maximum capacity (nominal load): 112 lbf | Maximum capacity (nominal load): 11.2 lbf | Maximum capacity (nominal load): 1.12 klbf | 10000 N rated capacity = 10 kN (1.0197 t mass equivalent at standard gravity); compression and tension | 1000 N rated capacity = 1 kN (101.9716 kg mass equivalent at standard gravity); compression and tension | 100 N rated capacity = 100 N (10.1972 kg mass equivalent at standard gravity); compression and tension | 2000 N rated capacity = 2 kN (203.9432 kg mass equivalent at standard gravity); compression and tension | 200 N rated capacity = 200 N (20.3943 kg mass equivalent at standard gravity); compression and tension | 5000 N rated capacity = 5 kN (509.8581 kg mass equivalent at standard gravity); compression and tension | 500 N rated capacity = 500 N (50.9858 kg mass equivalent at standard gravity); compression and tension | 50 N rated capacity = 50 N (5.0986 kg mass equivalent at standard gravity); compression and tension |
| Force range | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | -10000–10000 N | -1000–1000 N | -100–100 N | -2000–2000 N | -200–200 N | -5000–5000 N | -500–500 N | -50–50 N |
| source_sampling_rate_basis | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | ClipX fixed internal sampling rate; verify the configured filter and usable output bandwidth | ClipX fixed internal sampling rate; verify the configured filter and usable output bandwidth | ClipX fixed internal sampling rate; verify the configured filter and usable output bandwidth | MX840B maximum per-channel sample rate; sensor mechanics and filter settings can reduce usable bandwidth | ClipX fixed internal sampling rate; verify the configured filter and usable output bandwidth | MX840B maximum per-channel sample rate; sensor mechanics and filter settings can reduce usable bandwidth | ClipX fixed internal sampling rate; verify the configured filter and usable output bandwidth | DMP41 selectable result rate, intended for reference and calibration measurements |
| Interfaces | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | ethernet | ethernet | profinet | ethernet | profinet | ethernet | ethernet | ethernet |
| Accuracy (% FSO) | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | 0.02 % | 0.02 % | 0.02 % | 0.02 % | 0.02 % | 0.02 % | 0.02 % | 0.02 % |
| ADC sampling rate | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | 40000 samples/s | 19200 samples/s | 450 samples/s | 40000 samples/s | 450 samples/s | 40000 samples/s | 19200 samples/s | 19200 samples/s |
| Status | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active |
The industries we serve
Frequently asked questions
Answers to the most common questions about our products and services
No. The specified stop applies only up to 1000 N nominal force. Do not assume it exists on 2–10 kN models.
Z30A is a reference transducer for small tensile/compressive forces, calibration-machine verification and transfer measurements. Match calibration to the required force direction.
Yes. The manufacturer specifies integrated TEDS transducer identification for Z30A.
No. It also serves as a working standard and transfer transducer for calibration-machine verification and measurement traceability.
Housing and base connections allow cable routing suited to the installation and help avoid forces transmitted by the cable into the measurement. This matters particularly for small forces; select the connection for the force-introduction arrangement.