Skip to content

FAMILY 4534-B

FAMILY 4534-B: sensors and measurement devices by HBK for vibration.

Visit the HBK site (opens in a new tab)

Shared technical specifications for the series

Properties every model in the series has. What differs is in the models table below.

Range across models

The span covered by the models of the series together — not the range of each model.

Range across the models of FAMILY 4534-B
Frequency response 0.2–16000000 Hz
Operating temperature -60–150 °C
Phase response 1–10000 Hz
Acceleration sensitivity 9.8–490 mV/g

Models in the series

One column per model: what differs between the models of the series.

Models of FAMILY 4534-B compared by parameter
Parameter -4534-B– eli-m-8bff7077705ed05f633c2896 -4534-B-001- eli-m-9ffdf5ffcae548be3c997fa3 -4534-B-002- eli-m-d0cc62aad11af5a75db877ab -4534-B-004- eli-m-8bd2cb59ca75fbb7fbe0d508
Mounted resonance frequency 38000 Hz Not specified Not specified Not specified
Frequency response 0.2–12800 Hz 0.2–16000000 Hz 0.2–16000000 Hz 0.2–16000000 Hz
quantity_specification ±714 g indexed capacity; Uniaxial; General purpose; Clip mounting ±71 g indexed capacity; Uniaxial; General purpose; Clip mounting ±14 g indexed capacity; Uniaxial; General purpose; Clip mounting ±143 g indexed capacity; Uniaxial; General purpose; Clip mounting
source_linearity_basis Official indexed sensitivity tolerance: 10%. Official indexed sensitivity tolerance: 10%. Official indexed sensitivity tolerance: 10%. Official indexed sensitivity tolerance: 10%.
interface_specification Unknown Unknown Unknown Unknown
Operating temperature -60–150 °C -55–125 °C -55–125 °C -60–150 °C
source_sampling_rate_limited_by_readout True True True True
source_repeatability_basis HBK does not publish a separate scalar repeatability for every ordering code; use individual calibration and controlled mounting. HBK does not publish a separate scalar repeatability for every ordering code; use individual calibration and controlled mounting. HBK does not publish a separate scalar repeatability for every ordering code; use individual calibration and controlled mounting. HBK does not publish a separate scalar repeatability for every ordering code; use individual calibration and controlled mounting.
Phase response 1–10000 Hz 1–5000 Hz 2–1500 Hz 1000–5000 Hz
Acceleration sensitivity 9.800000000000001 mV/g 98 mV/g 490 mV/g 49 mV/g
source_vibration_sensor_output Piezoelectric CCLD (IEPE); Analogue Piezoelectric CCLD (IEPE); Analogue Piezoelectric CCLD (IEPE); Analogue Piezoelectric CCLD (IEPE); Analogue
Number of axes 1 1 1 1
Number of measurement channels 1 1 1 1
source_max_non_destructive_shock_gpk 10 000 g pk 10 000 g pk 10 000 g pk 10 000 g pk
source_sampling_rate_basis Sensor bandwidth is indexed by HBK; the selected conditioner and DAQ determine digital sample rate. Sensor bandwidth is indexed by HBK; the selected conditioner and DAQ determine digital sample rate. Sensor bandwidth is indexed by HBK; the selected conditioner and DAQ determine digital sample rate. Sensor bandwidth is indexed by HBK; the selected conditioner and DAQ determine digital sample rate.
source_acceleration_dc_response False False False False
Status Active Active Active Active

The industries we serve

Get a quote or advice

Tell us what you need and an engineer will come back to you.

Request a quote for this product
What would you like to ask for?

Email or phone — one of them is enough

Email or phone — one of them is enough

0 of 500 words