Family 6804
Family 6804: sensors and measurement devices by HBK for vibration.
Visit the HBK site (opens in a new tab)
Shared technical specifications for the series
Properties every model in the series has. What differs is in the models table below.
Range across models
The span covered by the models of the series together — not the range of each model.
| Acceleration sensitivity | 10–100 mV/g |
|---|---|
| Operating temperature | -54–107 °C |
Models in the series
One column per model: what differs between the models of the series.
| Parameter | -6804-B-001- eli-m-673cf503d8e5582dc3957b14 | -6804-B-002- eli-m-0d99eabb271a04b5c9bb955c |
|---|---|---|
| Acceleration sensitivity | 10 mV/g | 100 mV/g |
| interface_specification | Unknown | Unknown |
| Frequency response | 0–10000 Hz | 0–10000 Hz |
| Number of measurement channels | 1 | 1 |
| quantity_specification | ±500 g indexed capacity; Uniaxial; General purpose; Center bolt mounting | ±50 g indexed capacity; Uniaxial; General purpose; Center bolt mounting |
| Number of axes | 1 | 1 |
| Operating temperature | -54–107 °C | -54–85 °C |
| Status | Active | Active |
The industries we serve
Frequently asked questions
Answers to the most common questions about our products and services
These single-axis CCLD sensors have a case-isolated titanium housing, hermetic sealing and TEDS, supporting structural and multichannel measurements.
6804-B-001 has 10 mV/g sensitivity and a 500 g peak range. 6804-B-002 has 100 mV/g sensitivity and a 50 g peak range.
Response is specified from 0.3 Hz to 5 kHz at ±5%, and from 0.15 Hz to 10 kHz at ±15%. Choose the band according to the required response tolerance.
The electrical connection is a 10-32 coaxial connector to a CCLD input. Mounting uses the sensor 5-40 UNC-2B threaded provision.
No. 6804-B-001 is specified from −51 to +93 °C; 6804-B-002 from −51 to +82 °C.
Get a quote or advice
Tell us what you need and an engineer will come back to you.