Machine protection Vibration controllers

Machine protection: measurement controllers by Brüel & Kjær Vibro for vibration controllers.

Visit the Brüel & Kjær Vibro site (opens in a new tab)

Shared technical specifications for the series

Properties every model in the series has. What differs is in the models table below.

Range across models

The span covered by the models of the series together — not the range of each model.

Range across the models of Machine protection
Number of measurement channels 1–2
Operating temperature -30–65 °C

Models in the series

One column per model: what differs between the models of the series.

Models of Machine protection compared by parameter
Parameter VC-1000 eli-m-19a8fcd980babf98dd7f9b08 VC-1100 eli-m-505aa41fa674660b8a0f12bd VC-1500 eli-m-4bf961f813acf186134fc183 VC-850 eli-m-126caf52633c63f3c59206f7 VC-868 eli-m-4f1f85532ee64a4d9dd2c9cf VC-869 eli-m-cdaf87e78bc13be5cc1eaac4 VC-920 eli-m-8804955af9706c95cd02b5a4 VC-920-2k eli-m-ac4e6271a01b930336a5fa05
Number of measurement channels 1 2 2 1 1 1 1 1
Protection class (DIN EN 60529) ip65 ip65 ip20 Not specified ip65 ip65 ip20 ip20
source_linearity_basis Use the configured channel and sensor specifications for measurement uncertainty and protection-loop verification. Use the configured channel and sensor specifications for measurement uncertainty and protection-loop verification. Use the configured channel and sensor specifications for measurement uncertainty and protection-loop verification. Not specified Use the configured channel and sensor specifications for measurement uncertainty and protection-loop verification. Use the configured channel and sensor specifications for measurement uncertainty and protection-loop verification. Use the configured channel and sensor specifications for measurement uncertainty and protection-loop verification. Not specified
interface_specification Analog 0–10 V Plug-in terminal blocks 24 V DC logic inputs Not specified Relay alarm contact Relay alarm contact Two potential-free limit-relay contacts Not specified
source_repeatability_basis Verify the complete chain using the installed sensor, gap / mounting condition, channel module and calibration route. Verify the complete chain using the installed sensor, gap / mounting condition, channel module and calibration route. Verify the complete chain using the installed sensor, gap / mounting condition, channel module and calibration route. Not specified Verify the complete chain using the installed sensor, gap / mounting condition, channel module and calibration route. Verify the complete chain using the installed sensor, gap / mounting condition, channel module and calibration route. Verify the complete chain using the installed sensor, gap / mounting condition, channel module and calibration route. Not specified
Operating temperature 0–65 °C 0–50 °C 0–55 °C -20–65 °C -30–65 °C -30–65 °C 0–50 °C 0–50 °C
quantity_specification Die-cast housing, relay and analog outputs. Two channels; relay and analog outputs; RS-232 system connection. Two measurement points; systems of up to 40 devices via CAN bus. Not specified Single-channel robust vibration switch with relay alarm. Single-channel robust vibration switch with relay alarm. Control-cabinet mounting, chain OK monitoring and process-control output. Not specified
source_sampling_rate_basis Acquisition rate and waveform bandwidth depend on the selected monitor module and system configuration; no cross-model scalar is inferred. Acquisition rate and waveform bandwidth depend on the selected monitor module and system configuration; no cross-model scalar is inferred. Acquisition rate and waveform bandwidth depend on the selected monitor module and system configuration; no cross-model scalar is inferred. Not specified Acquisition rate and waveform bandwidth depend on the selected monitor module and system configuration; no cross-model scalar is inferred. Acquisition rate and waveform bandwidth depend on the selected monitor module and system configuration; no cross-model scalar is inferred. Acquisition rate and waveform bandwidth depend on the selected monitor module and system configuration; no cross-model scalar is inferred. Not specified
Frequency response Not specified 10–1000 Hz Not specified 10–1000 Hz Not specified Not specified Not specified Not specified
Status Active Active Active Active Active Active Active Active
Datasheet PDF — VC-1000 (opens in a new tab) PDF — VC-1100 (opens in a new tab) PDF — VC-1500 (opens in a new tab) PDF — VC-850 (opens in a new tab) PDF — VC-868 (opens in a new tab) PDF — VC-869 (opens in a new tab) PDF — VC-920 (opens in a new tab) PDF — VC-920-2k (opens in a new tab)