Technical specification
Every engineering figure, laid out to scan quickly
| Measuring range | 50 mm |
|---|---|
| Start of measuring range | 40 mm |
| End of measuring range | 90 mm |
| Working distance | 40–90 mm |
| Linearity | 10 µm |
| Repeatability | 1.6 µm |
| Interfaces | ethernet |
| interface_specification | Digital I/O |
| Operating temperature | 0–50 °C |
| Protection class (DIN EN 60529) | ip67 |
| interface_specification | Analog 0-10V |
| Light spot width X | 0.095 mm |
| Light spot width X | 0.22 mm |
| Light spot width X | 0.08500000000000001 mm |
| Light spot width X | 0.26 mm |
| Light spot width Y | 0.3 mm |
| Light spot width Y | 0.11 mm |
| Light spot width Y | 0.09 mm |
| Contact | Non-contact |