Skip to content

Models in the series

One column per model: what differs between the models of the series.

Models of MCS10 compared by parameter
Parameter K-MCS10-002-3C eli-m-23361f103a65c4d88701fe00 K-MCS10-002-6C eli-m-2be7e6d9549939b13d30ff9e K-MCS10-005-3C eli-m-b071d3e552c6be31f09bbdc6 K-MCS10-005-6C eli-m-6ea3fcc2e854730d7e5e05b2 K-MCS10-010-3C eli-m-e00c1ee26b91a1d5b13b03ab K-MCS10-010-6C eli-m-c8ca3af92efbc759aad4528c K-MCS10-025-3C eli-m-5aea17fa239e53dfc0fa3799 K-MCS10-025-6C eli-m-076593a791477447fcb70ef9 K-MCS10-050-3C eli-m-ad86559a494968ade6b35306 K-MCS10-050-6C eli-m-247fd6e5b9dd5027fb4f83f6 K-MCS10-100-3C eli-m-363374cea9290055c37f5a3a K-MCS10-100-6C eli-m-8275fcd2ed34856e25887436 K-MCS10-200-3C eli-m-f8fe95f2a00e0ed994234c8f K-MCS10-200-6C eli-m-bfa08929954b57b5c2b16b58
Interfaces ethercat ethernet ethercat ethernet ethernet ethercat ethernet ethernet ethercat ethernet ethercat ethercat ethernet ethercat
Accuracy (% FSO) 0.1 % 0.1 % 0.1 % 0.1 % 0.1 % 0.1 % 0.1 % 0.1 % 0.1 % 0.1 % 0.1 % 0.1 % 0.1 % 0.1 %
quantity_specification Fx/Fy ±500 N (50.9858 kg mass equivalent at standard gravity); Fz ±2 kN (203.9432 kg mass equivalent at standard gravity); 3C force-only version (no moment outputs) Fx/Fy ±500 N (50.9858 kg mass equivalent at standard gravity); Fz ±2 kN (203.9432 kg mass equivalent at standard gravity); Mx/My ±20 Nm; Mz ±20 Nm Fx/Fy ±1 kN (101.9716 kg mass equivalent at standard gravity); Fz ±5 kN (509.8581 kg mass equivalent at standard gravity); 3C force-only version (no moment outputs) Fx/Fy ±1 kN (101.9716 kg mass equivalent at standard gravity); Fz ±5 kN (509.8581 kg mass equivalent at standard gravity); Mx/My ±50 Nm; Mz ±50 Nm Fx/Fy ±2 kN (203.9432 kg mass equivalent at standard gravity); Fz ±10 kN (1.0197 t mass equivalent at standard gravity); 3C force-only version (no moment outputs) Fx/Fy ±2 kN (203.9432 kg mass equivalent at standard gravity); Fz ±10 kN (1.0197 t mass equivalent at standard gravity); Mx/My ±150 Nm; Mz ±150 Nm Fx/Fy ±5 kN (509.8581 kg mass equivalent at standard gravity); Fz ±25 kN (2.5493 t mass equivalent at standard gravity); 3C force-only version (no moment outputs) Fx/Fy ±5 kN (509.8581 kg mass equivalent at standard gravity); Fz ±25 kN (2.5493 t mass equivalent at standard gravity); Mx/My ±350 Nm; Mz ±250 Nm Fx/Fy ±10 kN (1.0197 t mass equivalent at standard gravity); Fz ±50 kN (5.0986 t mass equivalent at standard gravity); 3C force-only version (no moment outputs) Fx/Fy ±10 kN (1.0197 t mass equivalent at standard gravity); Fz ±50 kN (5.0986 t mass equivalent at standard gravity); Mx/My ±700 Nm; Mz ±500 Nm Fx/Fy ±20 kN (2.0394 t mass equivalent at standard gravity); Fz ±100 kN (10.1972 t mass equivalent at standard gravity); 3C force-only version (no moment outputs) Fx/Fy ±20 kN (2.0394 t mass equivalent at standard gravity); Fz ±100 kN (10.1972 t mass equivalent at standard gravity); Mx/My ±2 kNm; Mz ±1.5 kNm Fx/Fy ±40 kN (4.0789 t mass equivalent at standard gravity); Fz ±200 kN (20.3943 t mass equivalent at standard gravity); 3C force-only version (no moment outputs) Fx/Fy ±40 kN (4.0789 t mass equivalent at standard gravity); Fz ±200 kN (20.3943 t mass equivalent at standard gravity); Mx/My ±3.5 kNm; Mz ±3 kNm
ADC sampling rate 40000 samples/s 40000 samples/s 40000 samples/s 40000 samples/s 40000 samples/s 40000 samples/s 40000 samples/s 40000 samples/s 40000 samples/s 40000 samples/s 40000 samples/s 40000 samples/s 40000 samples/s 40000 samples/s
Force range -500–500 N -500–500 N -1000–1000 N -1000–1000 N -2000–2000 N -2000–2000 N -5000–5000 N -5000–5000 N -10000–10000 N -10000–10000 N -20000–20000 N -20000–20000 N -40000–40000 N -40000–40000 N
Force range Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified
Torque range Not specified -20–20 Nm Not specified -50–50 Nm Not specified -150–150 Nm Not specified -250–250 Nm Not specified -500–500 Nm Not specified -1500–1500 Nm Not specified -3000–3000 Nm
Torque range Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified
Status Active Active Active Active Active Active Active Active Active Active Active Active Active Active
Datasheet PDF — K-MCS10-002-3C (opens in a new tab) PDF — K-MCS10-002-6C (opens in a new tab) PDF — K-MCS10-005-3C (opens in a new tab) PDF — K-MCS10-005-6C (opens in a new tab) PDF — K-MCS10-010-3C (opens in a new tab) PDF — K-MCS10-010-6C (opens in a new tab) PDF — K-MCS10-025-3C (opens in a new tab) PDF — K-MCS10-025-6C (opens in a new tab) PDF — K-MCS10-050-3C (opens in a new tab) PDF — K-MCS10-050-6C (opens in a new tab) PDF — K-MCS10-100-3C (opens in a new tab) PDF — K-MCS10-100-6C (opens in a new tab) PDF — K-MCS10-200-3C (opens in a new tab) PDF — K-MCS10-200-6C (opens in a new tab)

The industries we serve

Frequently asked questions

Answers to the most common questions about our products and services

Depending on configuration, MCS10 measures up to six components: forces Fx, Fy, Fz and moments Mx, My, Mz. Capacity is specified separately for each component; one force rating is not a common capacity for every axis.

The individual matrix helps reduce crosstalk between measurement channels. HBK describes using it with a suitable measuring amplifier. Use the matrix and calibration data for the particular transducer rather than a generic family-wide matrix.

No. Despite the general headline, the configuration table includes classes 0.2, 0.1 and 0.15. Use the configuration column and keep linearity, repeatability and crosstalk separate.

No. TEDS is optional. Individual sensitivity is provided in the test certificate and can be stored in TEDS for the corresponding configuration.

They are distinct measurement-component and connection configurations. Select for the forces and moments needed, then use that exact configuration’s drawing and sensitivity data.

Didn't find the answer you were looking for?

Talk to an expert

More information

Get a quote or advice

Tell us what you need and an engineer will come back to you.

Request a quote for this product
What would you like to ask for?

Email or phone — one of them is enough

Email or phone — one of them is enough

0 of 500 words