thermoMETER UC: sensors and measurement devices by Micro-Epsilon for sensors.

Response time
0.12 s
Temperature measuring range
-50–900 °C
NETD
50 mK
Temperature accuracy
1 K
Download the datasheet (opens in a new tab) Visit the Micro-Epsilon site (opens in a new tab)

Technical specification

Every engineering figure, laid out to scan quickly

Technical specification for UC-SF15 / UC-SF22
Operating temperature -20–180 °C
Protection class (DIN EN 60529) ip65
Storage temperature -40–85 °C
source_sampling_rate_basis 120 ms 0-90% response time (8.33 Hz equivalent)
Temperature accuracy 1 K
ADC sampling rate 8.33 samples/s
Response time 0.12 s
Humidity 10–95 %RH
Interfaces profinet
Temperature accuracy (% of reading) 1 %
thermal_distance_spot_ratio 22
Temperature measuring range -50–900 °C
Temperature repeatability 0.5 K
interface_specification Analog 0-10V
Current consumption 150 mA
Temperature measuring range -50–1000 °C
Transmittance 0.1–1.1
Interfaces ethercat
Interfaces ethernet
Emissivity 0.1–1.1
source_linearity_basis Micro-Epsilon specifies system accuracy, repeatability and NETD; a separate linearity error is not published.
thermal_distance_spot_ratio 15
interface_specification 4-20mA
Supply voltage 5–36 V
temperature_repeatability_reading 0.5 %
quantity_specification -50 to +1000 C depending on selected UC optical head
NETD 50 mK
Spectral range 8000–14000 nm
Request a quote for this product

Compatible accessories

Power supplies

Complementary products

The industries we serve

Get a quote or advice

Tell us what you need and an engineer will come back to you.

Request a quote for this product
What would you like to ask for?

Email or phone — one of them is enough

Email or phone — one of them is enough

0 of 500 words