thermoMETER UC
thermoMETER UC: sensors and measurement devices by Micro-Epsilon for sensors.
Visit the Micro-Epsilon site (opens in a new tab)
Shared technical specifications for the series
Properties every model in the series has. What differs is in the models table below.
Range across models
The span covered by the models of the series together — not the range of each model.
| Operating temperature | -20–80 °C |
|---|---|
| Protection class (DIN EN 60529) | ip65 |
| Storage temperature | -40–85 °C |
| Temperature measuring range | -50–1000 °C |
| ADC sampling rate | 8–8.33 samples/s |
Models in the series
One column per model: what differs between the models of the series.
| Parameter | UC-SF02 eli-m-61512969cd013613a343ff7f | UC-SF15 eli-m-7f9a0a26aad65253b9d56557 | UC-SF15 / UC-SF22 eli-m-cb4a28b0b46ff7c2170f7572 | UC-SF22 eli-m-eda1ae10c621e94ab4a13171 |
|---|---|---|---|---|
| Operating temperature | -20–120 °C | -20–180 °C | -20–180 °C | -20–180 °C |
| Protection class (DIN EN 60529) | ip65 | ip65 | ip65 | ip65 |
| Storage temperature | -40–85 °C | -40–85 °C | -40–85 °C | -40–85 °C |
| Spectral range | 8000–14000 nm | 8000–14000 nm | 8000–14000 nm | 8000–14000 nm |
| Emissivity | 0.1–1.1 | 0.1–1.1 | 0.1–1.1 | 0.1–1.1 |
| Temperature measuring range | -50–600 °C | -50–600 °C | -50–900 °C | -50–1000 °C |
| interface_specification | RS422 / RS485 | Analog 0-10V | Analog 0-10V | 4-20mA |
| source_thermal_optical_resolution_ratio | 2:1 | 15:1 | Not specified | 22:1 |
| ADC sampling rate | 8 samples/s | 8.33 samples/s | 8.33 samples/s | 8 samples/s |
| Interfaces | usb | ethernet | profinet | ethernet_ip |
| Temperature accuracy | 1 K | 1 K | 1 K | 1 K |
| Response time | 0.12 s | 0.12 s | 0.12 s | 0.12 s |
| temperature_repeatability_reading | 0.5 % | 0.5 % | 0.5 % | 0.5 % |
| Current consumption | 150 mA | 150 mA | 150 mA | 150 mA |
| Supply voltage | 5–36 V | 5–36 V | 5–36 V | 5–36 V |
| Transmittance | 0.1–1.1 | 0.1–1.1 | 0.1–1.1 | 0.1–1.1 |
| Humidity | 10–95 %RH | 10–95 %RH | 10–95 %RH | 10–95 %RH |
| Temperature accuracy (% of reading) | 1 % | 1 % | 1 % | 1 % |
| Temperature repeatability | 0.5 K | 0.5 K | 0.5 K | 0.5 K |
| NETD | 50 mK | 50 mK | 50 mK | 50 mK |
| source_sampling_rate_basis | Not specified | 120 ms 0-90% response time (8.33 Hz equivalent) | 120 ms 0-90% response time (8.33 Hz equivalent) | Not specified |
| source_linearity_basis | Not specified | Micro-Epsilon specifies system accuracy, repeatability and NETD; a separate linearity error is not published. | Micro-Epsilon specifies system accuracy, repeatability and NETD; a separate linearity error is not published. | Not specified |
| quantity_specification | Not specified | -50 to +600 C for UC-SF15; 15:1 optics; ±0.5% or ±0.5 C repeatability; 50 mK NETD. | -50 to +1000 C depending on selected UC optical head | Not specified |
| thermal_distance_spot_ratio | Not specified | Not specified | 22 | Not specified |
| Status | Active | Active | Active | Active |
| Datasheet | PDF — UC-SF02 (opens in a new tab) | PDF — UC-SF15 / UC-SF22 (opens in a new tab) | PDF — UC-SF22 (opens in a new tab) |
The industries we serve
Frequently asked questions
Answers to the most common questions about our products and services
No. Its controller provides keys and a two-line display for local setup; sensorTOOL also supports PC configuration.
No. SF02/SF15 measure −50 to +600°C. SF22 reaches 900°C, optionally 1000°C. Head ambient limits are 120°C for SF02 and 180°C for SF15/SF22; the controller limit is 80°C.
RS485 is onboard, while Ethernet, EtherCAT, PROFINET and EtherNet/IP require an interface module. USB also requires the specified cable or adapter.
Match SF02, SF15 or SF22 to distance and target size using the spot-distance table. A close-focus lens changes the geometry, so use the relevant optical table.
The table specifies ±1% or ±1°C, whichever is greater, for target temperature above 0°C, ambient 24±2°C and ε=1. Retain those measurement conditions.