Skip to content

Technical specification

Every engineering figure, laid out to scan quickly

Technical specification for CSE05
Measuring range 1 mm
Start of measuring range 0 mm
Measuring window 0–0.5 mm
Linearity 0.25 µm
Resolution 0.01 µm
Recommended target diameter 6 mm
Minimum target diameter 6 mm
Interfaces ethernet
interface_specification Analog 0-10V
Number of measurement channels 1
Storage temperature -50–200 °C
Operating temperature -50–200 °C
Protection class (DIN EN 60529) ip40
Weight 0.002 kg
quantity_specification 0-0.5 mm model-level measuring interval
source_temperature_stability_um_per_k -0.02 µm/K
source_recommended_mounting_position_mm 3.0 mm
active_area_published_size 3.9 mm
Measuring window 0–1 mm
Interfaces ethercat
Resolution 0.00015 µm
Resolution 0.009999999999999998 µm
Measuring range 0.5 mm
source_linearity_basis Official sensor linearity from the current capaNCDT catalog; total measuring-channel linearity also includes the DT6230 + DL6230 controller contribution.
Number of measurement channels 4
Measuring window 0–0.25 mm
source_sampling_rate_basis DL6220: 5 kHz bandwidth; DT6220 digital rate 3.906 kSamples/s
source_linearity_basis Official sensor linearity from the current capaNCDT catalog; total measuring-channel linearity also includes the DT6228 + DL6228 controller contribution.
Number of measurement channels 2
source_linearity_basis Official sensor linearity from the current capaNCDT catalog; total measuring-channel linearity also includes the DT6112 controller contribution.
Measuring range 0.25 mm
source_sampling_rate_basis DL6230: 5 kHz bandwidth; DT6220 digital rate 3.906 kSamples/s
source_linearity_basis Official sensor linearity from the current capaNCDT catalog; total measuring-channel linearity also includes the DT6220 + DL6220 controller contribution.
source_linearity_basis Official sensor linearity from the current capaNCDT catalog; total measuring-channel linearity also includes the DT6240 + DL6220 controller contribution.
Number of measurement channels 8
source_sampling_rate_basis DT6112 high-speed controller: 20 kHz bandwidth
source_sampling_rate_basis DT6110/IP: IP68 single-channel controller with 1 kHz bandwidth
source_linearity_basis Official sensor linearity from the current capaNCDT catalog; total measuring-channel linearity also includes the DT6530 (2-channel base) + DL6510 + CP6001 controller contribution.
source_linearity_basis Official sensor linearity from the current capaNCDT catalog; total measuring-channel linearity also includes the DT6530 (2-channel base) + DL6510 + CPM6011 controller contribution.
source_sampling_rate_basis DT6110: 1 kHz analog measurement bandwidth
source_sampling_rate_basis DL6230: 5 kHz bandwidth; DT6230 digital rate 3.906 kSamples/s
interface_specification RS422 / RS485
source_sampling_rate_basis DL6510 with CPM6011: 8.5 kHz bandwidth in the official maximum-eight-channel DT6530 base system
source_sampling_rate_basis DL6220: 5 kHz bandwidth; DT6230 digital rate 3.906 kSamples/s
source_sampling_rate_basis DL6530: 8.5 kHz bandwidth; DT6530 digital rate 7.8 kSamples/s at 4 channels or 3.9 kSamples/s at 8
interface_specification 4-20mA
source_sampling_rate_basis DT6120: 1 kHz analog bandwidth; up to 2 kSamples/s over RS485
source_linearity_basis Official sensor linearity from the current capaNCDT catalog; total measuring-channel linearity also includes the DT6240 + DL6230 controller contribution.
source_linearity_basis Official sensor linearity from the current capaNCDT catalog; total measuring-channel linearity also includes the DT6120/IP controller contribution.
source_sampling_rate_basis DL6228: 1 kHz bandwidth and 3.906 kSamples/s digital rate; optimized for CSE/HT sensors
source_sampling_rate_basis DL6510 with CP6001: 8.5 kHz bandwidth in the official maximum-eight-channel DT6530 base system
source_sampling_rate_basis DL6220: 5 kHz bandwidth; DT6240 digital rate 3.906 kSamples/s
source_linearity_basis Official sensor linearity from the current capaNCDT catalog; total measuring-channel linearity also includes the DT6530 (8-channel base) + DL6510 + CP6001 controller contribution.
Interfaces profinet
source_sampling_rate_basis DL6230: 5 kHz bandwidth; DT6240 digital rate 3.906 kSamples/s
source_linearity_basis Official sensor linearity from the current capaNCDT catalog; total measuring-channel linearity also includes the DT6220 + DL6230 controller contribution.
source_linearity_basis Official sensor linearity from the current capaNCDT catalog; total measuring-channel linearity also includes the DT6530 (8-channel base) + DL6530 controller contribution.
source_linearity_basis Official sensor linearity from the current capaNCDT catalog; total measuring-channel linearity also includes the DT6530 (8-channel base) + DL6510 + CPM6011 controller contribution.
source_sampling_rate_basis DT6120/IP: IP68 single-channel controller with 1 kHz analog bandwidth and up to 2 kSamples/s over RS485
source_linearity_basis Official sensor linearity from the current capaNCDT catalog; total measuring-channel linearity also includes the DT6230 + DL6220 controller contribution.
source_linearity_basis Official sensor linearity from the current capaNCDT catalog; total measuring-channel linearity also includes the DT6120 controller contribution.
source_sampling_rate_basis DL6530: 8.5 kHz bandwidth in the official maximum-two-channel DT6530 base system
source_sampling_rate_basis DL6510 with CP6001: 8.5 kHz bandwidth in the official maximum-two-channel DT6530 base system
source_linearity_basis Official sensor linearity from the current capaNCDT catalog; total measuring-channel linearity also includes the DT6110 controller contribution.
source_sampling_rate_basis DL6510 with CPM6011: 8.5 kHz bandwidth in the official maximum-two-channel DT6530 base system
source_sampling_rate_basis DL6222: 20 kHz bandwidth; DT6222 digital rate 3.906 kSamples/s
source_linearity_basis Official sensor linearity from the current capaNCDT catalog; total measuring-channel linearity also includes the DT6222 + DL6222 controller contribution.
source_linearity_basis Official sensor linearity from the current capaNCDT catalog; total measuring-channel linearity also includes the DT6238 + DL6228 controller contribution.
source_linearity_basis Official sensor linearity from the current capaNCDT catalog; total measuring-channel linearity also includes the DT6530 (2-channel base) + DL6530 controller contribution.
source_linearity_basis Official sensor linearity from the current capaNCDT catalog; total measuring-channel linearity also includes the DT6110/IP controller contribution.
Contact Non-contact
Request a quote for this product

Compatible system components

Controllers

  • DT6110 eli-m-3a9a07a0e16c8d276da5c3ec Required
  • DT6112 eli-m-363afdc0101726a3c7386066 Required
  • DT6120 eli-m-d469830ad426a1ff0a6d310c Required
  • DT6110/IP eli-m-bb97255d2237f1b4fead83d4 Required
  • DT6120/IP eli-m-6bd760f9ed329b48dd8bb009 Required
  • DT6220 eli-m-dca5c37c03b2062835c5bd89 Required
  • DT6230 eli-m-e96035364c44419048b0f016 Required
  • DT6240 eli-m-252e13b64762316d5fb1252f Required
  • DT6222 eli-m-fccaa95e9a52c9fb84092dc2 Required
  • DT6228 eli-m-39e18189b2646a8af462315d Required
  • DT6238 eli-m-fe33c37d1fde6ed890ff35ee Required
  • DT6530 eli-m-846a49c39c106bb30c86a902 Required

Compatible accessories

Cables

  • CCg eli-m-2de7a3194142736f2c7ea2c3
  • CCg/PT eli-m-e21071f22bbcd9f1682ff75b
  • CCm eli-m-8b9f829350510ac2ee7404c4
  • CCo eli-m-f56e9667458330d1138ce5d3
  • PC6200-x/4 eli-m-b0e46ffb0598fbe6a82afc41
  • SC6000-x eli-m-93680f9f0a413b9c4b69087f
  • SCACx/5 configurable component family eli-s-63090a88954ac684d10c1303 Only for source configuration configuration-b2aa0aa42250ae92c978aa15: CSE05; selected configuration must be matched before display.
  • SCACx/6 configurable component family eli-s-2707dbe76cd43e02ff56da8d Only for source configuration configuration-d65ae7d8f42c031a55f7e4f1: CSE05; selected configuration must be matched before display.
  • SCACx/6/IP configurable component family eli-s-e1a5c0e60bcd87ef2645a09d Only for source configuration configuration-a4e39ad96354fe0ae68c175c: CSE05; selected configuration must be matched before display.
  • SCACx/4 configurable component family eli-s-0ff9e5d0db5c61bbad7d6e8e Only for source configuration configuration-5f3c6ceb01716a24a7f1d051: CSE05; selected configuration must be matched before display.
  • CAx configurable component family eli-s-8a1cf8c350120d89edfded32 Only for source configuration configuration-5f5b695ee605670df5342f7c: CSE05; selected configuration must be matched before display.

Accessories

  • 0323050 eli-m-a0150f88c95dbe5fcec40b9d
  • 0323346 eli-m-6b4570e12399777d844bcbe8
  • 0323349 eli-m-d12e7275de50ef53acbc6abe

Mounting

  • MA-CS-2-C eli-m-22f789295888f8bd5ac34a87
  • MA-CS3 eli-m-0ece2dadfcb97ff52381f79f

Power supplies

Complementary products

  • IF1032/ETH eli-m-9f23885a1bd1bd049fa826c5
  • CP6001 eli-m-ee14179d45127fbe4a5bb59d
  • CMP6011 eli-m-48dfabeb6adde90890f548dd

The industries we serve

Frequently asked questions

Answers to the most common questions about our products and services

The manufacturer lists a nominal range of 0.5 mm, a reduced range of 0.25 mm and an extended range of 1 mm. These are range modes of the same head, not three values to combine into one interval. Accuracy and resolution conditions must remain attached to the relevant range mode.

No. It is a capacitive sensor head with a triaxial connection and needs a compatible controller and cable. The manufacturer lists compatibility with all capaNCDT controllers. A modular 62xx or 65xx system also requires an appropriate channel module; selecting the head alone does not complete the assembly.

No. The head lists linearity below ±0.25 µm under the table conditions, and the manufacturer identifies it as a sensor-only value. Add the controller contribution on the same range basis. The head specification refers to the nominal range and a standard 1.4 m CCm cable.

The table lists 0.15 nm static and 10 nm dynamic resolution. Its footnote specifies RMS measurements with DT6530, the nominal range and a 1.4 m CCm cable: static at 2 Hz and dynamic at 8.5 kHz bandwidth. These ratings must not be assigned to every other controller without verification.

Didn't find the answer you were looking for?

Talk to an expert

More information

Get a quote or advice

Tell us what you need and an engineer will come back to you.

Request a quote for this product
What would you like to ask for?

Email or phone — one of them is enough

Email or phone — one of them is enough

0 of 500 words